CliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack

SKU CLI-STER-BI-R60-50 · CliniEco Medical
$269.99
In stock · ships from Toronto, ON
Fluorescence biological indicatortype
1 hour (60 minutes)readout time
50 testspack quantity
Fluorescence reader (e.g. 4-well rapid reader)requires
Pack sizeSingle configuration Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping across Canada — included

Specifications

TypeFluorescence biological indicator
Readout time1 hour (60 minutes)
Pack quantity50 tests
RequiresFluorescence reader (e.g. 4-well rapid reader)
UseSteam autoclave sterilization monitoring
SKUCLI-STER-BI-R60-50
BrandCliniEco Medical

Pricing

OrderUnit price
1 unit$269.99 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 15 sections · specs, use, compliance
Proof for this lot — D-value report (steam, 121 °C) · lot-level CoA on request · Health Canada MDEL #35334. How we verify sterilization monitoring →

Rapid-readout sterilization monitoring — results in 1 hour, not 24 hours.

The 1-hour vial answers a scheduling question, not a biological one: can this load go back into the chair before the day ends? Fifty self-contained vials (model ZJ60) arrive in one box, and every result is read on the CliniEco Rapid Reader at 58 ± 2 °C — there is no colour change to read by eye.

CliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack

Which sterilizer cycles can a 1-hour biological indicator be used in?

Vacuum and gravity cycles both, on saturated steam at the three temperatures a Canadian clinic actually runs: 121 °C, 132 °C and 134 °C. The vial carries Geobacillus stearothermophilus ATCC 7953 at a population of at least 1.0 × 10⁶ c.f.u. with a D-value of at least 1.5 minutes at 121 °C, and it incubates at 58 ± 2 °C. The organism and the reference standards — ISO 11138-1 and ISO 11138-3 — are the same as our 24-hour line, so one sterilizer can run both tiers without splitting the monitoring programme or the logbook format. What changes is the wait, not the organism or the cycle it monitors.

How long does the 1-hour result take, and when can the load go back into use?

Sixty minutes from activation, with no overnight hold and no second visit. In practice: run the cycle, activate the vial, read it at the hour mark, and release the load if the result is negative. A positive result is a failed load and it stays failed — re-clean, re-pack, re-sterilize, and look at the sterilizer before it runs again. One indicator per load, every day the sterilizer runs, placed where steam is hardest to reach: in a dental load that means inside the pouch or cassette, not loose in the chamber.

What does the 1-hour tier cost per sterilization day, and how far does one box go?

A box of 50 vials, priced on this page, works out to a per-test figure by dividing the box amount by fifty. Monitoring that follows the pattern in RCDSO Standard 5542 for Ontario dental practices uses a test plus a control on each day the sterilizer runs, so a sterilization day consumes two vials and one box covers 25 such days. Per-day cost decides a tier: the 24-hour self-contained vial costs less per day, the 3-hour fluorescence vial sits below this tier per day, and the 20-minute vial sits above it.

Readout tier by release window — cost per sterilization day and box to order (CAD)
Release window Tier that fits Cost per sterilization day Box to order
Set must return to the chair in the same session 20 minutes, reader required Divide the box amount by the vials in the box 50 vials, $289.99
Load released before the working day ends 1 hour, reader required — this listing Divide the box amount by the vials in the box 50 vials, $269.99
Release after the morning list 3 hours, reader required Divide the box amount by the vials in the box 50 vials, $249.99
Release next morning, low volume 24 hours, colour change by eye Divide the box amount by the vials in the box 50 vials, $109.99
Release next morning, several cycles a day 24 hours, 100-vial box Divide the box amount by the vials in the box 100 vials, $189.00
Occasional testing, small practice 24 hours, 25-vial box Divide the box amount by the vials in the box 25 vials, $69.99

Where the figure meets the logbook. The vial lot number goes against the load on the day of the test; the printable daily record on the compliance log centre has a column for it, and the compliance desk will answer a written question about your own sterilizer where the standard you follow reads differently. If you would rather work the number from your own case mix, the clinic supply planner multiplies sterilizer days by vials per day. Related tiers: 3-hour fluorescence 50-pack and 24-hour self-contained 50-pack. CliniEco Medical supplies this line under MDEL #35334.

Each vial contains Geobacillus stearothermophilus ATCC 7953 spores in a self-contained format. After the sterilization cycle the vial is activated and incubated, and the result is read by fluorescence — a positive (failed) and negative (passed) result is reported by the reader, not by eye.

How it differs from our 24-hour indicator

  • Readout: 1 hour instead of 24 hours
  • Reader required — this model is read on the CliniEco Rapid Reader (4-well fluorescence reader). It is not a colour-change product, so it cannot be interpreted visually.
  • Same spore strain and same ISO reference as our 24-hour line, so both can sit in one monitoring programme.

Specifications

Model ZJ60
Readout time 1 hour
Format Self-contained vial, rapid readout (enzymatic / fluorescence)
Organism Geobacillus stearothermophilus ATCC 7953
Reference standard ISO 11138-1 and ISO 11138-3, moist heat (per manufacturer specification)
Incubation 58 ± 2 °C (use with the CliniEco Rapid Reader)
Pack size 50 vials per box
Intended use Routine monitoring of steam (moist heat) sterilization cycles
Storage Follow the manufacturer's instructions supplied with the box; keep the vials in their original packaging and do not add any label or tape to the vial or cap

Readout times across our biological indicator line

Model Readout Result read by
Rapid 20 minutes (ZJ20) 20 minutes CliniEco Rapid Reader
Rapid 1 hour (ZJ60) 1 hour CliniEco Rapid Reader
Rapid 3 hours (ZJ180) 3 hours CliniEco Rapid Reader
24-hour self-contained (ZJ1440) Up to 24 hours (early read at 8 / 12 h) Visual colour change

Price per test, and when the 1-hour tier is worth it

Each of the three fluorescence 50-packs is priced on its own page, and the per-test figure follows there by dividing the box amount by fifty. Against the 20-minute tier this one costs less per test; against the 3-hour tier it costs more. Over 240 tests (two indicators per test day, 120 test days) the gap between adjacent tiers stays small enough that readout speed, not price, is the reason to move up or down a tier.

This is the tier for a load that has to be released inside the working session, but not inside the half hour: a normal clinic day of two or three cycles, or a shared reader where a 20-minute read would hold up the queue. If results can wait until the end of the day, the 3-hour indicator is cheaper; if the instruments are needed back immediately, the 20-minute one is faster.

Who it is for

Dental clinics, medical clinics and laboratories that run daily steam sterilization and need a same-day, documented result — for example where a load cannot be released until the biological indicator reads negative.

What you need with it

  • CliniEco Rapid Reader — 4-well fluorescence reader (required for this model)
  • Incubation at 58 ± 2 °C
  • Batch record: record the vial lot number against the sterilizer load

Documentation

Manufacturer's instructions for use are supplied with every box. A certificate of analysis per batch is available on request — the lot number on the box is traceable to the release documentation.

How to run a test

  1. Place the indicator in the load, in the area that is hardest to sterilize (for a typical dental load: with the instruments in the pouch or cassette).
  2. Run the sterilization cycle as normal.
  3. After the cycle, follow the vial activation step described in the manufacturer's instructions — the vial is activated, then incubated.
  4. Place the vial in the CliniEco Rapid Reader and incubate at 58 ± 2 °C. The reader reports the result at the readout time above.
  5. Record the result and the vial lot number against the sterilizer load log.

One indicator per load, every day. Do not add any label or tape to the vial or its cap — it interferes with the incubation and read.

Interpreting the result

  • Negative (pass) — the spores were killed; the load may be released.
  • Positive (fail) — spores survived. Do not release the load: re-clean, re-pack and re-sterilize, and check the sterilizer before using it again. Retain the indicator and the load record.
  • This model is read by the reader only. Unlike our 24-hour indicator, there is no colour change to read by eye — the result must come from the reader.

Official manufacturer specifications

Readout time 1 hour
Incubation range 15–60 minutes
Organism Geobacillus stearothermophilus ATCC 7953
Population ≥ 1.0 × 10⁶ c.f.u. (mean per strip)
D-value ≥ 1.5 min at 121 °C (steam)
Test conditions 121 °C / 132 °C / 134 °C saturated steam — vacuum and gravity cycles
Standards ISO 11138-1 and ISO 11138-3 compliant (manufacturer declaration)
Pack size 50 vials per pack
Frequency of use One test per sterilization cycle
Kit contents BI ampoules and culture media tubes

Parameters as published by the manufacturer. Batch certificate of analysis is traceable from the lot number on the box.

Have a question about your own facility? Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. Ask your compliance question.

Related tests in this BI line

Related articles

Common questions

How long does Biological Indicator take to give a readout?

Results are read in 1 hour, not 24 hours.

Does it work with my autoclave cycle type?

This item is used with standard steam sterilization cycles; confirm the specific cycle against the manufacturer's instructions supplied with each lot.

Which standard does it meet?

Manufactured and tested to ISO 11138-1, ISO 11138-3 and ISO 11140-5.

How should it be stored, and how long does it keep?

Store between 15–30 °C at 30–65% relative humidity, keep away from sterilants, direct sunlight and UV, and do not crush the packaging. Shelf life is 24 months from the date of manufacture.

How often does a Canadian clinic need to run it?

In Ontario, RCDSO requires a biological indicator plus a control test, once daily for each type of cycle on every sterilizer in use — so 1 sterilizer × 20 working days = 40 indicators a month including the control. In Quebec, ODQ's PCI guidance requires weekly biological monitoring for each cycle type (daily is recommended, not required); Bowie-Dick is daily and only for pre-vacuum (Class B) cycles.

Can I read it by eye?

No. Rapid-readout models are read on the fluorescence reader.

Do I need the reader as well?

Yes — the reader is required for this model. Our 24-hour self-contained indicator does not need a reader (visual colour change).

Why choose 20 minutes over the 24-hour indicator?

When the load cannot be released until the result is known — same-day reprocessing, single-set practices, or where a 24-hour hold is operationally not possible.

Is it the same organism as the 24-hour indicator?

Yes, Geobacillus stearothermophilus ATCC 7953 under ISO 11138-3 — so both can be used in one monitoring programme.

Storage?

As printed on the box and in the manufacturer's instructions. Keep vials in the original packaging and do not relabel them.