Williams Periodontal Probe: Sizes, Markings and Colour Codes Explained

Carton and stacked self-sealing pouches showing the indicator area and the write-on field where a probe load is dated

Williams Periodontal Probe: Sizes, Markings and Colour Codes Explained

A 4 mm pocket reading depends on one detail: which groove the gingival margin sits against. That is why a Williams pattern has to be read properly, because the probe marks 1, 2, 3, 5, 7, 8, 9 and 10 mm, skipping the two positions that would clutter the scale.

What markings does a Williams periodontal probe carry?

Eight marks, at 1, 2, 3, 5, 7, 8, 9 and 10 mm, with uneven spacings on purpose: 1 to 2, 2 to 3, then a 2 mm gap to 5, 2 mm to 7, and single millimetres to 10. A probe is a reusable stainless instrument, so the purchase rarely stops at the probe, and the 6 L benchtop ultrasonic cleaner with dual-frequency 32/48 kHz is where a used probe starts its cycle.

Which colour code belongs to which probe pattern?

Pattern Marks (mm) Colour banding Tip
Williams 1, 2, 3, 5, 7, 8, 9, 10 none in the classic form tapered, single millimetre graduations
UNC-15 1 to 15, every millimetre dark bands at 4-5, 9-10, 14-15 tapered
WHO, CP-11 style 3.5, 5.5, 8.5, 11.5 one band at each mark 0.5 mm ball tip
Marquis 3, 6, 9, 12 alternating colour blocks tapered

Stainless steel ultrasonic cleaner tank with a wire instrument basket inside, the first stage of a used probe cycle

Buy on the pattern, not the colour. Two probes can carry identical colours and different graduations, which is how a clinic ends up with two sets of readings that cannot be compared across visits.

What do ISO 21672-1 and 21672-2 actually cover?

Part 1 sets the general requirements for a periodontal probe and Part 2 the designation system a manufacturer uses to describe one. Both current editions are dated 2012, and Part 1 is in confirmed status, reconfirmed on 19 September 2023, so a catalogue quoting it quotes a live edition. The same cannot be said for ISO 13397-4:1997, withdrawn on 19 April 2021: it dealt with area-specific curettes, and a probe page still citing it is quoting a retired document.

How is a Williams probe processed between patients?

Carton and stacked self-sealing pouches showing the indicator area and the write-on field where a probe load is dated

It is reusable, so it travels: cleaning first with the cassette in the bath, then a pouch, a seal and a steam cycle, with the load recorded. A clinic buying probes therefore buys the line around them: the constant-heat pouch sealer with a 12 mm seal at 200 degrees C and the self-sealing Class 4 pouches with a dual indicator, 200 per box belong in the same order as the instrument.

How do you read a Williams probe at the chair?

Read to the nearest mark, then estimate the fraction rather than rounding up. Record six sites per tooth and keep the same pattern in the same operatory, because the 2 mm gaps in a Williams pattern are not where a UNC-15 reading sits. If two clinicians chart the same patient in the same week, the pattern is what makes the charts comparable.

Which pattern should a clinic standardise on?

The one the charting software and the team both read without a conversion step. A Williams pattern suits a practice reading single millimetres on a compact, unbanded scale; a UNC-15 suits deep pockets where a 4-5 band reads faster. Standardise per operatory, and hold a spare of each size the protocol names.


Ordering for a clinic group or a multi-site practice? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

Running a dental practice? See our dental practice supplies.

References

  1. ISO 21672-1:2012 — Dentistry, periodontal probes, Part 1: General requirements (stage 90.93, confirmed 19 September 2023) (checked 31 October 2026)
  2. ISO 21672-2:2012 — Dentistry, periodontal probes, Part 2: Designation (published 2012) (checked 31 October 2026)
  3. ISO 13397-4:1997 — Dentistry, periodontal curettes, scalers and probes, Part 4 (stage 95.99, withdrawn 19 April 2021) (checked 31 October 2026)

Printable companion: the printable reprocessing log carries the fields an inspection asks for, so a probe cycle is written down as it happens.

Want the sheet built around your cycle type? The sterilization log generator prints a record with the columns your documentation needs.

Related Reading

Frequently Asked Questions

What are the markings on a Williams periodontal probe?

Markings at 1, 2, 3, 5, 7, 8, 9 and 10 mm. The 4 mm and 6 mm positions are deliberately left unmarked, so the reader counts grooves rather than relying on a band.

Does a Williams probe have colour codes?

Not in the classic form. The graduation is engraved, and colour-coded variants add bands at the same positions without changing where a depth is read.

Which ISO standard applies to a periodontal probe?

ISO 21672, in two parts: Part 1 covers general requirements and Part 2 the designation system. Both current editions are dated 2012, and Part 1 was reconfirmed on 19 September 2023.

Can a catalogue cite ISO 13397-4 for a periodontal probe?

It should not. ISO 13397-4:1997 was withdrawn on 19 April 2021 and dealt with area-specific curettes, so a probe described that way is being described with a retired edition.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Already working with clinics? Become a regional representative.