CliniEco Ultrasonic Cleaner — 20 L Bench Unit, CS20 with Heater and Drain Valve
Specifications
| Tank capacity | 20 L (5.3 US gal) — chamber 42 × 26 × 20 cm |
|---|---|
| Transducers | 8, distributed across the tank floor |
| Power | 500 W ultrasonic, 500 W heating, AC 100–120 V, North American plug |
| SKU | CLI-ULTRA-CLEAN-200 |
| Brand | CliniEco Medical |
| Category | Sterilization & Cleaning Equipment |
| Availability | In stock |
Pricing
| Order | Unit price |
|---|---|
| 1 unit | $1,199.00 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 9 sections · specs, use, compliance
Quick answer: A 20 L chamber with eight transducers, 500 W of ultrasonic power and 500 W of heating — built for a clinic running several chairs, or a laboratory cleaning in batches.
At 20 L the tank stops being a bench accessory and becomes a station. The chamber is 42 × 26 × 20 cm, the unit is 54 × 37 × 40 cm and weighs 17 kg dry, and eight transducers are distributed under the floor so coverage holds across the full length rather than concentrating in the middle. It can sit on a counter or be installed recessed into one, which is usually how a multi-chair clinic handles a tank this size.
Scope of use. This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The Health Canada guidance on reprocessing information is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.
What are the CS20 specifications?
The two numbers that decide an installation are the loaded weight and the footprint: a 20 L working volume is roughly 20 kg of water plus a 17 kg unit.
Tank capacity: 20 L (5.3 US gal) — chamber 42 × 26 × 20 cm
Transducers: 8, distributed across the tank floor
Power: 500 W ultrasonic, 500 W heating, AC 100–120 V, North American plug
Unit dimensions: 54 × 37 × 40 cm; net weight 17 kg, gross 20 kg
Installation: Bench or recessed; noise-reduced cabinet, four-level circuit protection
Drain: Electric drain valve
| Field | Specification |
|---|---|
| Tank capacity | 20 L (5.3 US gal) — chamber 42 × 26 × 20 cm |
| Tank dimensions | 42 × 26 × 20 cm (length × width × depth) |
| Transducers | 8, distributed across the tank floor |
| Power | 500 W ultrasonic, 500 W heating, AC 100–120 V, North American plug |
| Unit dimensions | 54 × 37 × 40 cm; net weight 17 kg, gross 20 kg |
| Installation | Bench or recessed; noise-reduced cabinet, four-level circuit protection |
| Drain | Electric drain valve |
| Electrical certification | cETL — Intertek report 260210005GZU-001, to UL 73 and CSA C22.2 No. 68 |
| Included | Unit, one-year manufacturer warranty; stainless basket available as an accessory |
| List price | CAD $1,199.00 |
Does this unit log cleaning cycles?
No. The CS20 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.
What the CS20 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.
Five fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.
Which tank size in the range fits your room?
This is the largest unit in the range and it is not the right unit for a two-chair practice. The sizes below it cover one chair, one cassette, or two chairs in one cycle; 20 L is for a room where the tank runs continuously or where instruments arrive in bulk.
| Model | Tank | Frequency | Built for | List price (CAD) |
|---|---|---|---|---|
| CS4.0 | 4 L | 32 / 48 kHz | Single chair, loose instruments | $449.00 |
| CD-4862 | 6 L | 35 kHz | Full cassette, five temperature presets | $649.00 |
| CS6.2 | 6 L | 32 / 48 kHz | Full cassette, dual frequency | $699.00 |
| CD-4875 | 7.5 L | 35 kHz | Larger trays, five temperature presets | $849.00 |
| CS8.0 | 8 L | 49 kHz | Two chairs into one cycle | $999.00 |
| CS20 | 20 L | 35 kHz | Several chairs or batch work | $1,199.00 |
Plan the bench before the unit arrives. A loaded 20 L tank is about 37 kg on a 54 × 37 cm footprint, and it needs to sit within reach of a drain or a container you are willing to carry. Recessing it removes the lifting problem and is the reason this model has a noise-reduced cabinet.
How do you run a repeatable cleaning cycle on the CS20?
A tank this size changes the workflow question from ‘does it fit the bench’ to ‘who owns the cycle’. One person should own the fill level, the solution change interval and the log.
| Step | Setting | Why it matters |
|---|---|---|
| 1. Fill | 20 L working volume with solution at the label dilution | The dose scales with the load, not with the tank shell |
| 2. Heat | Bring to the solution label temperature before the first load | A large tank takes longer to reach temperature; the first load is the one that gets rushed |
| 3. Load | Baskets or trays, eight-transducer coverage across the length | Even spacing uses the whole floor instead of the centre |
| 4. Run | Full cycle per load; do not add solution mid-cycle | Adding cold solution mid-cycle resets the working temperature |
| 5. Drain, dry, record | Electric drain valve, dry the chamber, log the batch | Batch records are what a laboratory audit samples |
The failure mode on large tanks is drift: the level drops as baskets come out wet, someone tops it up with water, and after a week the concentration is half what the label says. Keep a marked fill line and change solution on a schedule, not on appearance.
What an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for documentation and maintenance of records for each component of the cleaning, disinfection and/or sterilization process, based on the manufacturer’s recommendations, and repeats that records must be retained according to the facility’s policy (Public Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.
What does the cETL mark cover, and what does it not?
The CS20 sits under a different Intertek report from the smaller units — 260210005GZU-001 — which is the number to quote if a technician or an inspector asks which certificate covers this family. The mark on the unit is an ETL mark issued by Intertek, tested against UL 73 and CSA C22.2 No. 68. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, CSA Z314:23, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.
| Covers | Does not cover |
|---|---|
| Electrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68 | Cleaning performance on your instruments, on your water hardness, or at your solution concentration |
| The specific unit family named on Intertek report 260210005GZU-001 | The condition of an individual unit after a drop, a repair, or a modification |
| Compliance of the supply, plug and cord assembly for the North American market | Any clinical outcome, or any claim that the unit removes or inactivates micro-organisms |
| The identity of the certificate holder and the factory it was issued to | Your own reprocessing records, which are yours to keep and produce |
What is in the box, and what should be ordered with it?
One cleaner, 20 L, 110 V with a North American plug and the manufacturer warranty. Basket as an accessory. Because the unit can be recessed, confirm the cut-out dimensions with us before the bench is built rather than after.
Multi-enzyme ultrasonic cleaning solution is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The 6 L CS6.2 is the unit to look at if your load grows into full cassettes. Read how to choose a tank size and what to record on the cleaning log before you commit to a size.
What does one tank fill cost in cleaning solution?
At 20 L the chemistry line stops being a rounding error and starts being a purchasing decision: a full tank takes about 50 mL at 1:400, a 1 L bottle gives twenty fills and a 5 L pail a hundred. That is why batch work is costed per tank rather than per instrument — the fill, not the piece, is the unit of spend.
| Dilution on the label | Concentrate per full tank (20 L) | Fills from a 1 L bottle | Fills from a 5 L pail |
|---|---|---|---|
| 1:400 — heavier soil | ≈ 50 mL | 20 fills | 100 fills |
| 1:600 — light soil | ≈ 33.3 mL | 30 fills | 150 fills |
Cost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 20 fills is roughly 4 working weeks from one bottle.
Which cleaning solution goes in this tank, and when should it be changed?
The 20 L chamber takes the multi-enzyme ultrasonic cleaning concentrate in 1 L bottles or 5 L pails at 1:400 to 1:600. A larger tank holds a larger free surface, so the low-foam formulation is doing real work here: foam that would be a nuisance in a 4 L bath can blanket a 20 L one. Label window: 20–50 °C, 2 to 10 minutes, 24 months sealed, 90 days open.
Change the bath when the label and your protocol say to, and record the change as part of the cleaning record — the electric drain valve on this unit exists so that a 20 L change is a routine task rather than a two-person one. Ontario reprocessing guidance asks for documentation and maintenance of records for each component of the cleaning, disinfection and/or sterilization process (Public Health Ontario provincial reprocessing guidance, 3rd edition, checked 2026-11-07).
What is the lead time, and what maintenance does the unit need?
This unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.
| Task | Interval | Why it matters |
|---|---|---|
| Drain and refill | At the interval the solution label and your protocol set | Soil load accumulates in the bath whatever the instruments look like when they come out |
| Run a fresh fill before the first load | Every refill | Dissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in |
| Rinse tank and basket | Every change | Residue left on stainless carries soil into the next fill and films the tank over time |
| Wipe lid and check cord, plug and drain valve | Weekly | The three parts a drop or a wipe-down damages first |
| Keep the level above the working minimum | Every cycle | Running dry is the one failure mode that ends a tank’s service life early |
With eight transducers across the tank floor, a full tank is also a steadier tank: filling to the working level keeps the load immersed and the field even, and never letting the level fall onto the heaters is the one rule that protects the unit.
Related reading
- Choosing an Ultrasonic Cleaner Tank Size for a Canadian Dental Clinic
- Verifying Instrument Cleaning: Protein Residue Tests, TOSI and Cavitation Methods
- How Much Does an Ultrasonic Cleaner Cost in Canada? 2026 Price Bands
CliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our sterilization desk.
Built to order. Allow 3–4 weeks — we confirm the dispatch date before the unit ships.
Common questions
How heavy is a 20 L ultrasonic cleaner when it is full?
About 37 kg working weight: a 17 kg unit plus roughly 20 kg of water at the 20 L working volume. That is why this model is usually installed recessed into a bench rather than lifted, and why the drain valve matters.
Can the CS20 be installed under a counter?
Yes — it is designed for counter-top or recessed installation, with a noise-reduced cabinet and four-level circuit protection. The unit is 54 × 37 × 40 cm, so the cut-out has to be planned before the bench is built.
How many transducers does the 20 L tank have?
Eight, spread across the tank floor, with 500 W of ultrasonic power and a separate 500 W heater. The distribution is the point: a single transducer in a 42 cm chamber leaves cold spots at the ends.
Is a 20 L tank overkill for a two-chair office?
Yes. Two chairs' hand instruments in one cycle is an 8 L job, and a single cassette is a 6 L job. A 20 L tank is for a clinic running several chairs continuously or a laboratory cleaning in batches.
What certification does the CS20 carry?
A cETL mark from Intertek under report 260210005GZU-001, tested to UL 73 and CSA C22.2 No. 68. It is an electrical safety certificate issued by Intertek; it is not a UL listing and it is not CSA certification.