Sterilization compliance kit B for gravity non-vacuum - 24-hour BI 50-pack, Class 5 integrators

Sterilization Compliance Kit — B — For Gravity / Non-Vacuum Sterilizers

SKU CLI-STER-KIT-GRAV · CliniEco Medical
$189.00
In stock · ships from Toronto, ON
CLI-STER-KIT-GRAVsku
Sterilization Monitoringcategory
CliniEco Medicalbrand
In stockavailability
Pack sizeSingle configuration Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping over $99 in Ontario · $199 rest of Canada

Specifications

SKUCLI-STER-KIT-GRAV
BrandCliniEco Medical
CategorySterilization Monitoring
AvailabilityIn stock
Ships fromToronto, ON

Pricing

OrderUnit price
1 unit$189.00 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 13 sections · specs, use, compliance

B — For gravity / non-vacuum sterilizers

Everything one sterilizer needs to keep its monitoring in order for a month — with 10% spare, so a busy week never leaves you short.

Kit B is the compliance kit for one gravity (non-vacuum) sterilizer. If you are weighing it against the vacuum version, the matching set for Class B units is Sterilization Compliance Kit A, and the practical difference between the two is the air-removal test each one carries.

Sterilization Compliance Kit — B — For Gravity / Non-Vacuum Sterilizers

What is in the Kit B box, and what does each item actually prove?

Four monitoring items, each answering a different question. The 24-hour biological indicators are the spore test: one vial for every day the sterilizer runs, plus a control, incubated at 58 ± 2 °C before reading. The Class 5 integrators sit inside trays and large packs, where they respond to time, temperature and steam as a single reading. The Class 4 pouches carry internal and external indicators on each package, so the wrapper itself shows exposure. The indicator tape holds the wrap closed and shows the load went through.

Kit B contents — quantity per kit and what each item confirms
Item in the box Quantity per kit What it confirms When it is used
Biological indicator, 24-hour readout 50 vials Spores were killed in the load Every day the sterilizer runs, with one control
Steam chemical integrator, Class 5 100 strips Time, temperature and steam reached the pack interior Inside trays and large packs, every load
Sterilization pouch, Class 4 dual indicator 4 boxes × 200 = 800 pouches Package was exposed, inside and out Every instrument package
Autoclave indicator tape, 3-roll set 3 rolls Wrap stayed closed and went through the cycle Wrapped trays and loose pouches
Bowie-Dick test pack None — not required on a gravity unit Air removal in the chamber Pre-vacuum (Class B) sterilizers only

How much does Kit B cost, and how far does one kit go?

The kit is $189.00 and sized for one sterilizer on a normal schedule for about a month. The quantities follow the daily test rule rather than a round number: 50 biological indicators means a test plus a control for each day the unit runs, with spare for a heavy week. The same box holds 100 Class 5 integrators, four boxes of 200 pouches and a three-roll tape set. Two sterilizers need two kits — the spare inside one kit is not sized to carry a second chamber.

What has to be written on the daily record this kit feeds?

One line per cycle day: the date, which sterilizer, the load or cycle number, the biological indicator lot with its control result, the integrator reading taken from the pack, the initials of whoever released the load, and what was done when a result did not pass. That sheet is what an inspector reads first, and it is also what lets a clinic trace a lot backwards after a failed spore test. The printable version and a generator that fills in the cycle columns are both there for the taking.

Print the daily sterilization log, build the columns with the log generator, put setup questions to our compliance desk, and order for several chairs or a second site through clinic ordering.

Kit B ships from CliniEco Medical, a Canadian medical device establishment holding MDEL #35334.

Why buy this kit from us

Sterilization compliance for clinics is all we do. So the kit comes with the parts most suppliers leave out:

  • Quantities we can show you the working for — built on the RCDSO's daily testing rule, with spare so a busy week never leaves you short. No guessing at how much you actually use.
  • The record sheet your province asks for — ready to print, free, no account, nothing to buy.
  • A named person who can look up your lot number — email alina@clinieco.ca. Not a ticket queue.
  • Any compliance question, any time — ask us; even if you never buy anything from us, we're glad to talk it through.

What it does not do: it won't tell you whether a cycle passed. That depends on how the sterilizer is loaded and run — that part stays with your team. We supply the monitoring and the guidance around it, not a guarantee of outcomes.

Questions clinics ask before buying

Do I need an incubator?

Yes. These indicators have to be incubated at 58 ± 2 °C before you can read them. A self-contained indicator does not need a reader, but it does need an incubator. If your clinic doesn't have one, we stock one — or email us and we'll help you sort it out rather than send you something you can't use.

How do I know this is the right kit for my sterilizer?

Kit B is for gravity / non-vacuum sterilizers — the ones without a vacuum pump. Pre-vacuum (Class B) units need a daily Bowie-Dick test and belong on Kit A instead.

How long does one kit last?

About a month for a clinic running one sterilizer on a normal schedule. The 50 biological indicators are sized on the RCDSO requirement of a test plus a control each day the sterilizer runs, with spare for the busier weeks.

Why is there no Bowie-Dick test in this kit?

Bowie-Dick tests air removal in the chamber, which only applies to pre-vacuum (Class B) sterilizers. On a gravity unit it is not required, so you are not paying for it.

Can I buy the items separately?

Yes — every item in the kit is sold on its own. The kit is for clinics that would rather not work out the quantities, not a way to lock you into a bundle.

What if I run more than one sterilizer, or more than 2 chairs?

Email us before ordering and we'll size it for your volume. The kit is built for a 1–2 chair clinic running one autoclave — it is not meant for 6+ chairs.

Where these numbers come from

  • Biological indicator every day the sterilizer runs, plus a control test — RCDSO Standard 5542, p. 8 (and 5539, p. 23). That is the basis for 50 indicators a month, not 25.
  • Bowie-Dick: pre-vacuum / Class B only, first cycle of each day — RCDSO 5542, p. 7; Public Health Ontario 7.18. A gravity sterilizer does not require it, which is why it is in Kit A only.
  • Pouch count is based on a 3–4 chair practice running 400–750 pouches a month; we round up so you don't run short.

Verified 2026-10-08. If your provincial requirements differ, tell us — we'd rather correct the kit than have you rely on the wrong number.

What's in the kit

  • Biological Indicator — 24-Hour Readout, 50-Pack × 1
  • Steam Chemical Integrator — Class 5, 100-Pack × 1 (for your trays and large packs)
  • Sterilization Pouch — Class 4 Dual Indicator, 200-pack box × 4
  • Autoclave Tape — Sterilization Indicator Tape, 3-Roll Set × 1

No Bowie-Dick test pack — that test applies to pre-vacuum (Class B) sterilizers only. If yours is pre-vacuum, choose Kit A.

Designed for: 1–2 chairs · one gravity (non-vacuum) sterilizer · no dedicated infection-control staff

Not for: pre-vacuum (Class B) sterilizers — see Kit A · 6+ chairs (larger volume — ask us) · sterilizers other than steam

Covers — products, guidance, records, a specialist who can see your lot number

Does not cover — whether a cycle passes. That depends on how the sterilizer is operated and loaded — that part stays with your team.

Running a pre-vacuum (Class B) sterilizer? That is Kit A.

Related articles

Common questions

What sizes or formats does Sterilization Compliance Kit come in?

The 50 biological indicators are sized on the RCDSO requirement of a test plus a control each day the sterilizer runs, with spare for.