CliniEco LED Face Mask — 7 colour light modes

CliniEco LED Light Therapy Face Mask — Red & Blue Light

SKU CLI-LED-MASK · CliniEco Medical
$299.99
In stock · ships from Toronto, ON
Wavelength bandchannel
415–450 nmblue
630–660 nmred
CLI-LED-MASKsku
Pack sizeSingle configuration Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping across Canada — included

Specifications

ChannelWavelength band
Blue415–450 nm
Red630–660 nm
SKUCLI-LED-MASK
BrandCliniEco Medical
CategoryFace Protection
AvailabilityIn stock

Pricing

OrderUnit price
1 unit$299.99 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 6 sections · specs, use, compliance

CliniEco LED Light Therapy Face Mask — Red & Blue Light

Notes: Specifications, packaging and pricing shown are indicative and will be confirmed before launch. No therapeutic claims are made on this page.

CliniEco Medical · Imported and distributed in Canada by Ecology Source New Energy Technology Co., LTD. · Health Canada MDEL #35334

Which wavelengths does a red and blue LED mask actually deliver?

A mask sold as red and blue is delivering two different photobiomodulation bands, and they are not interchangeable. Blue light in the 415–450 nm range is absorbed by porphyrins inside Cutibacterium acnes, which is the mechanism behind its use in mild inflammatory acne. Red light around 630–660 nm is absorbed by cytochrome c oxidase in the mitochondrial respiratory chain and is the band most studied for photoageing and wound repair. Near-infrared, usually 810–850 nm, penetrates furthest and is the band normally added when a device claims deeper tissue coverage. Green and yellow channels appear on many multi-colour panels but do not add a separate mechanism at the same level of evidence, so a seven-colour panel should not be read as seven treatments. Output also falls with distance, so the figure that matters is irradiance at the skin, not at the diode.

How do you convert session minutes into a dose you can compare?

Dose in joules per square centimetre is irradiance multiplied by time: J/cm² = mW/cm² × seconds ÷ 1,000. A panel delivering 30 mW/cm² for ten minutes gives 18 J/cm²; the same panel for twenty minutes gives 36 J/cm², and a 10 mW/cm² panel needs thirty minutes to reach the same 18 J/cm². Two devices quoting ten minutes per session are therefore not comparable unless both quote irradiance at the treatment distance. Ask for the radiometer measurement, the distance at which it was taken, and whether the figure is an average over the treated area or a peak at the centre. That single number separates a clinical device from a decorative one, and it is the number most listings leave out.

Which safety standard applies to a light mask: IEC 62471 or IEC 60825-1?

Incoherent light sources such as LED arrays fall under IEC 62471:2006, Photobiological safety of lamps and lamp systems, which sorts a product into the Exempt Group or risk group RG0 to RG3 according to the blue-light and infrared hazards it presents at a defined distance. IEC 60825-1:2014 is the laser standard and applies to lasers, not to an LED mask; a supplier citing it for an LED product is citing the wrong document. For a mains-powered mask, electrical safety is covered by IEC 60601-1:2005 with Amendment 1:2012 and Amendment 2:2020, and electromagnetic compatibility by IEC 60601-1-2:2014 with Amendment 1:2020. A clinic file should hold the IEC 62471 test report with the risk group stated at the treatment distance, not only a claim that the device is eye safe.

Who should not be treated without a clinician's sign-off?

Photosensitivity is the main exclusion, whether it comes from a condition or from medication that makes skin react to light. Anyone taking a photosensitising medicine, and anyone with active eczema, rosacea or a recent chemical peel, should be cleared before a course starts rather than after a reaction. Opaque eye protection is worn for the whole session, because the blue-light hazard weighting peaks in the same 400–500 nm band that the acne programme uses. Treat the mask as a shared device: clean the inner surface between users according to the manufacturer's validated method, log date, duration and setting for every session, and stop the course if skin becomes irritated instead of working through the schedule.

What should a clinic ask before it standardises on one mask?

Five questions sort the market quickly: the wavelength and bandwidth of each channel, irradiance at the stated treatment distance, the IEC 62471 risk group, the electrical and EMC test reports, and the cleaning method the manufacturer has validated. Ask for the dose schedule the clinical evidence was generated with, not the schedule that fits a marketing page. Buyers comparing models can record the answers side by side in the clinic supply planner, and a treatment log kept with the forms in the compliance log centre gives the audit trail if a client asks what was delivered. Background on the evidence base sits in our guides to red, blue and green light for different skin concerns and to whether home light masks do what they claim.

Channel: Wavelength band

Blue: 415–450 nm

Red: 630–660 nm

Near-infrared: 810–850 nm

Green and yellow: Approx. 520–590 nm

Whole device: —

LED light therapy face mask: channel, target and verification point
Channel Wavelength band Reported target What to verify
Blue 415–450 nm Porphyrins in C. acnes Bandwidth and irradiance quoted per channel
Red 630–660 nm Cytochrome c oxidase Irradiance at the treatment distance
Near-infrared 810–850 nm Deeper tissue layers Whether the array is true NIR or a filtered visible channel
Green and yellow Approx. 520–590 nm Positioning, not a separate mechanism Whether a distinct clinical mechanism is claimed
Whole device — Photobiological safety IEC 62471:2006 risk group at a stated distance
Whole device — Electrical and EMC safety IEC 60601-1:2005+A1:2012+A2:2020; IEC 60601-1-2:2014+A1:2020
Reusable surface — Infection control between users Manufacturer-validated cleaning method and a session log

CliniEco Medical lists this LED light therapy mask for the Canadian market under MDEL #35334, as part of a catalogue of clinic consumables and equipment. Requirements outside the catalogue are quoted through the wholesale enquiry desk.

Related articles

Common questions

How many light colours does this face mask produce?

2 light colours, red and blue, in one wearable mask. The page is a pre-launch information page, so the final specification sheet and the order price are confirmed before sale.

Is this the same device as the seven-colour mask?

No, this is a separate product with 2 light colours, while the 7-colour mask has 7 modes. The two listings are not interchangeable, and pricing is quoted per order through the B2B quotation route, not listed on the page.

Can I buy this mask now?

The listing states that the page is published for information and search purposes and that the product is not available for purchase at this time. The packaging shown is indicative, and the order price for this 2-colour unit is confirmed before launch.

Are therapeutic claims made for this mask?

No therapeutic claims are made on the page, and neither of the 2 light modes is presented as treating a condition. It is described as light therapy equipment for cosmetic routine use only.

Who imports and distributes this mask in Canada?

CliniEco Medical of Toronto, Ontario, under MDEL #35334. One Canadian distributor of record covers the documentation and support contact for the device.

How do I get the specification before launch?

Request the pre-launch data sheet through the product page enquiry form, and the 2 light colours, session timing and packaging will be confirmed in writing. Interest registered now is used to set the first production quantity.