CliniEco Biohazard Medical Waste Bags - Red, 30 Gallon, Leak-Proof
Specifications
| SKU | CLI-WB-30G-RD-5PK |
|---|---|
| Brand | CliniEco Medical |
| Category | Medical Waste |
| Availability | In stock |
| Ships from | Toronto, ON |
Pricing
| Order | Unit price |
|---|---|
| 1 box | $54.95 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 19 sections · specs, use, compliance
Product Overview
CliniEco Medical Waste Bags provide compliant, reliable waste containment for healthcare facilities across Canada. Each bag is manufactured from high-quality polyethylene with enhanced puncture and tear resistance.
What has to be on a red bag before a clinic can put it into service?
Three things, all visible on the bag itself: the red film, the biohazard symbol, and a marking that reads in both English and French. Those are the three the listing states for this bag, and they are the checks that can be made at goods-in without unrolling the pack. Which stream the bag is then used for, and how full it may be filled, is set by the rules of the province the facility operates in — the bag is the containment, and the provincial rule is the instruction sheet that goes with it.
Where does a 30-gallon bag sit in a clinic's waste stream?
At the point where a treatment room's waste leaves the room. A 30-gallon bag lines the bin that collects a day of soft biomedical waste, is closed at the neck when the bin is changed, and moves to storage without being decanted into anything else. Sharp items do not belong in it at any stage: they go into a rigid 1-quart sharps container first, which is the division that keeps whoever carries the bag from meeting a needle.
Is a leak-proof seam on its own enough?
No, and the page states the pair to look for together: sealed leak-proof seams plus enhanced puncture and tear resistance in the polyethylene film. A seam that holds while the film splits under the weight of a dropped bin fails the same way as the reverse. Handling then does the rest — lift by the gathered neck rather than a corner, keep the bag off the floor between changes, and never press waste down to make room for more.
How is a perforated roll used on a ward cart?
One bag is torn off at the perforation and the roll is left closed, so the bags that follow stay rolled, clean and out of the light until the bin is changed again. That is the practical reason for the roll format rather than a loose bundle: the bag in service is the only bag exposed, and the cart carries a known number of changes rather than a pile.
When is the compostable bag the wrong choice?
When the waste processor will not take it. The PLA compostable bag in the same 30-gallon format is the alternative this listing points to, and the 24 × 32 inch PLA bag covers the smaller room bin. A compostable film only does what it claims inside a stream that accepts it, so the question for the waste contractor comes before the order rather than after it.
Does this listing cover a smaller treatment room?
This listing is the 30-gallon red bag in a 5-pack, and the smaller formats in the range are the PLA bags above. Size the order from bin changes rather than from shelf space: a room that fills a 30-gallon bin once a week is over-bagged, a room that fills one every day needs more than a single pack on hand, and the count of bin changes per week multiplied by the weeks between deliveries is the quantity to hold.
Capacity: 30
Colour: red
Marking: biohazard symbol
Film: polyethylene
Seam: leak-proof, sealed
Dispensing format: perforated roll
Capacity: 30
Colour: red
Marking: biohazard symbol
Film: polyethylene
Seam: leak-proof, sealed
Dispensing format: perforated roll
| Property | Value | Unit / format |
|---|---|---|
| Capacity | 30 | gallon |
| Colour | red | biohazard waste stream |
| Marking | biohazard symbol | bilingual English / French |
| Film | polyethylene | puncture and tear resistant |
| Seam | leak-proof, sealed | along both sides and base |
| Dispensing format | perforated roll | one bag per tear-off |
| Order unit on this listing | 5 | 5-pack (single variant) |
| Compostable alternative | PLA, 30 gallon | separate listing |
The disposal workflow this bag sits inside — segregation, closure, storage and handover — is set out in 
Distributed in Canada by CliniEco Medical, Toronto. Bulk quantities for facilities are quoted through the clinic ordering desk.
Key Features
- Intended for biomedical waste collection — provincial and municipal requirements apply
- Distinctive red color with clear biohazard symbol and bilingual (English/French) marking
- Leak-proof sealed seams prevent tears during handling
- Perforated roll design for easy dispensing
- Also available in PLA compostable material
Clinic & Volume Pricing
Wholesale pricing available for healthcare facilities. Request your quote →
How many bags are in the pack, and what does one bag cost?
The pack holds five bags, so at $54.95 the cost is $10.99 per bag. That is the number to put against a bin change: a treatment room that changes a 30-gallon bin once a working day uses about 21 bags a month, which is four packs with one bag over, and a room on twice-weekly changes uses about nine. Buying by the pack and counting changes is more accurate than buying by the month, because the waste stream follows appointments rather than the calendar.
| Item | Value | Planning use |
|---|---|---|
| Bags per pack | 5 | Single variant on this listing |
| Pack price | $54.95 | — |
| Cost per bag | $10.99 | Multiply by bin changes per month for a budget line |
| Capacity | 30 gallon | Lines the bin a treatment room fills in a day |
| Packed weight | 6.0 kg per 5-pack | About 1.2 kg per bag packed — plan shelf and freight |
| Format | Perforated roll | One bag exposed at a time on a cart |
Which colour and label does Ontario require for the waste this bag takes?
Ontario's biomedical waste guideline, C-4: The management of biomedical waste in Ontario (checked 2 November 2026), sets containment and labelling by waste category in its Table A, and the result is not one colour for everything. Human anatomical waste takes a red label with the anatomical symbol; human blood waste takes a yellow label with the universal biohazard symbol; cytotoxic waste takes a red label with the cytotoxic symbol; and waste that has come into contact with human blood that is infected or suspected of being infected takes a red label with the universal biohazard symbol. A red bag carrying the universal biohazard symbol therefore belongs to that last row — infected or suspected-infected blood-contaminated waste — and a clinic that treats every red bag as interchangeable is one segregation audit away from a finding.
| Waste category | Label required | Refrigeration |
|---|---|---|
| Human anatomical waste | Red label — anatomical symbol | At all times |
| Human blood waste | Yellow label — universal biohazard symbol | If stored more than 4 days |
| Microbiology laboratory waste | Yellow label — universal biohazard symbol | If stored more than 4 days |
| Blood waste infected or suspected infected | Red label — universal biohazard symbol | At all times |
| Cytotoxic waste | Red label — cytotoxic symbol | Not specified |
| Sharps waste | Yellow label — universal biohazard symbol, rigid container | Not specified |
How is a bag's film strength specified and tested?
"Leak-proof" and "puncture resistant" are claims; the film properties behind them are measured by named test methods. Tear resistance of plastic film is measured by the pendulum method in ASTM D1922-23, Standard Test Method for Propagation Tear Resistance of Plastic Film and Thin Sheeting by Pendulum Method, and impact resistance by the free-falling dart method in ASTM D1709-24, Standard Test Methods for Impact Resistance of Plastic Film by the Free-Falling Dart Method (both checked 2 November 2026). Neither standard is a pass mark a bag either has or lacks; each produces a number for a given film, and the number is only meaningful next to the film thickness and the load it will carry.
| Designation | What it measures | Question to put to a supplier |
|---|---|---|
| ASTM D1922-23 | Force to propagate a tear through film, pendulum method | Tear value for the film used, and at what thickness |
| ASTM D1709-24 | Energy causing film to fail under a free-falling dart | Dart impact value, and the failing weight method used |
| Ontario C-4, s. 4 | Container must withstand the weight of the waste without tearing, cracking or releasing | Whether the liner and outer container were assessed together |
What does the container rule require beyond the bag itself?
The bag is a liner, not the container. C-4 requires a single-use biomedical waste container to be an unlined rigid, leak-proof drum or pail, or a sealable outer cardboard container lined with a leak-proof plastic film that can be securely tied — and the container has to withstand the weight of the waste without tearing, cracking, crushing or releasing it. The same guideline requires the storage area to be secure, away from supply and food areas, and clearly marked with the universal biohazard symbol. A clinic that has bought the right bags but lines a flimsy bin has satisfied the film requirement and failed the one that matters when a full bag is lifted.
Par levels, from bin changes rather than from shelf space
Count the changes, then the packs. A single-chair room that fills one 30-gallon bin a working day needs about 21 bags a month, so four packs on hand covers a month with a spare; a room on twice-weekly changes needs two packs; a multi-room floor adds the rooms rather than the weeks. Hold the re-order point at half a pack, and keep the bags rolled and closed between changes so the roll on the cart carries a known number of changes rather than a pile.
Where the bag sits in the waste workflow
The record of each pickup prints from the compliance log centre, and the log generator on that page dates each sheet so a transfer can be matched to a bin change. Sharps never enter the bag: they go into a rigid 1-quart sharps container first. Where a waste contractor will not accept a compostable film, the PLA 30-gallon bag and the smaller 24 × 32 inch PLA bag cover the alternative streams. Segregation and closure questions go to the compliance desk, and facility quantities are quoted through the clinic ordering desk. Distributed in Canada by CliniEco Medical — MDEL #35334.
Related Reading
Learn more about choosing and using this product category:
- PLA Waste Bag Total Cost: Comparing Biodegradable and Poly Bags
- Medical Imaging Center Supplies: Gloves, Caps and Waste Bags
- Medical Waste Bag Pricing in Canada: Cost per Bag by Size (2026)
Related Guides
Learn how to choose and use this product correctly:
- Biohazard Waste Disposal in Canadian Healthcare: Standards and Compliance
- Medical Sharps Disposal in Canada: Regulatory Requirements for Clinics and Hospitals
- Specimen Transport Bags for Canadian Diagnostic Laboratories: Biohazard Safety and Regulatory Compliance Guide
- Red Biohazard Waste Bags 30 Gallon: Regulatory Compliance Across Canadian Provinces
Related supplies for the same workflow
- CliniEco PLA Biodegradable Waste Bags - Eco-Friendly, 30 Gallon
- CliniEco PLA Waste Bags — 24×32 inch, 150 Bags (3 × 50-Pack Case)
Related articles
- Double Bagging Medical Waste: When a Second Bag Helps and When It Adds Risk
- Closing and Lifting a Full Red Bag: Gooseneck Tie, Bag Stands and Where the Seam Fails
- Medical Waste Bags Bulk Order Ontario: Red Bag Sizes and Par Levels
- Blood, Suction Fluid and Semi-Solid Waste: Handling Liquid Medical Waste in Canadian Clinics
Common questions
What sizes does Biohazard Medical Waste Bags - Red, 30 Gallon, Leak-Proof come in, and which size fits a standard instrument tray?