Which Standards Apply to Protégé Nitrile Exam Gloves in Canada Clinics
A Mississauga family practice changed glove suppliers in September, and the first case arrived with four pieces of paper in the lid. The buyer had ordered a Protégé nitrile exam glove, 4.0 mil, 1,000 gloves per case, and the question that followed was which of those four papers actually applies in Canada.
Which standards apply to Protégé nitrile exam gloves in Canada clinics?
Four documents do the work, and only one is about the glove as a product.
ASTM D6319 is the specification an examination glove is measured against: dimensions by size, tensile strength before and after ageing, elongation at break, and watertightness. ASTM D5151 is the method used to look for holes, which is where the AQL figure printed on the case comes from. ISO 10993-1:2018 covers the biological evaluation a glove needs because it sits against skin for long stretches. ASTM F1671 applies only where the supplier claims resistance to bloodborne pathogens, which is the claim a chemo-grade line stands on.
Above all four sits the Canadian market layer: a glove sold as a medical device needs a device licence, and the company importing it needs an establishment licence. The number worth asking for is the importer's.
| Layer | Document | What it fixes |
|---|---|---|
| Product specification | ASTM D6319 | Dimensions, tensile strength, elongation, watertightness |
| Hole detection | ASTM D5151 | Test method behind the AQL printed on the case |
| Biological safety | ISO 10993-1:2018 | Skin-contact evaluation |
| Barrier claim | ASTM F1671 | Viral penetration, only where the claim is made |
| Market access | Device and establishment licensing | Who may import and sell |

Which documents should travel with a case into a clinic?
Four, and each answers a different question. A declaration that the lot was made and tested to ASTM D6319 answers what the glove is. The lot's watertight AQL result answers how many failures the batch may contain. The ISO 10993-1 statement answers what it is made of and whether that has been assessed for skin contact. The instructions for use answer how long a glove may be worn and what it must not be used with.
What does not exist is a per-carton certificate from the federal regulator. Establishments get registered and devices get licensed by risk class; nobody stamps a box. A supplier offering "certification" has produced something else, and it is worth asking what.
What should the case print?
The standard and its edition year, the AQL for watertightness, the lot number, the size, the count per inner box, and the manufacturer plus importer names. Two of those are routinely skipped by buyers. The lot number is what makes a tear complaint traceable to one production run; the count per box is where a ten-box case and a seven-box case stop being the same order. A case carries a single size, so the size mix has to be planned before the case is bought, not after.

Which line fits which task?
| Line | Thickness | Case format | Where it fits |
|---|---|---|---|
| Protégé | 4.0 mil | 1,000 gloves (10 × 100) | Exam and procedure rooms where the barrier statement matters |
| Robust | 4.5 mil | 1,000 gloves (10 × 100) | Longer wear and heavier handling |
| Transform 100 | 3.2 mil | 1,000 gloves (10 × 100) | High-change tasks where tactility beats thickness |
What is missing from that table is deliberate: colour and price move between lots, thickness and the barrier statement do not. High-turnover rooms usually land on the 3.2 mil Transform 100 case.
What should be checked when the first case arrives?
Five checks, in order. Count the inner boxes against the purchase order. Open one box and check that gloves release from each other without tearing. Read the printed standard and lot against the paperwork. Confirm the sizes match the mix the clinic actually uses. Then log the lot, the received date and who opened it — a 4.5 mil line for heavier handling and the 4.0 mil exam line should appear as separate rows, because a complaint about one is not a complaint about both.
The glove lot page in our supply log templates takes a minute per case and answers a batch question months later.
Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
Running a walk-in or multi-practitioner site? Clinic consumables groups the glove, tape and prep lines a room turns over every week.
References
- ASTM D6319 — Standard Specification for Nitrile Examination Gloves for Medical Application (checked 3 November 2026)
- ASTM D5151 — Standard Test Method for Detection of Holes in Medical Gloves (checked 3 November 2026)
- ISO 10993-1:2018 — Biological evaluation of medical devices, Part 1 (checked 3 November 2026)
- ASTM F1671 — Resistance of materials to penetration by blood-borne pathogens (checked 3 November 2026)
Working out how many cases a chair or an exam room gets through? The clinic supply planner turns daily glove changes into a monthly case count.
Related Reading
- Nitrile Gloves in Canada vs the United States: Which Standards Apply?
- Protégé Nitrile Exam Gloves Options Compared for a Canadian Clinic in Alberta
- Nitrile Glove Quality Requirements: What Canadian Buyers Should Verify Before Ordering
Frequently Asked Questions
Which standards apply to Protégé nitrile exam gloves in Canada clinics?
ASTM D6319 for the glove itself, ASTM D5151 for the hole test behind the AQL figure, ISO 10993-1 for skin-contact biological evaluation, ASTM F1671 where a bloodborne-pathogen claim is made, and federal device and establishment licensing above them.
Is there a Health Canada certificate for a glove?
Not on the carton. The federal regulator registers establishments and licenses devices by risk class, so what a buyer receives is a supplier declaration plus a licence reference, not a per-box certificate.
What does the AQL number on the case mean?
It is the acceptance quality limit for the watertightness test: the failure rate the lot is allowed before it is rejected. Examination grade nitrile commonly declares 1.5, and the number is per lot, not per brand.
Does 4.0 mil mean the same thing on every glove line?
No. Thickness is measured at the palm by most manufacturers, and a 4.0 mil exam glove with a chemo-grade statement is not interchangeable with a 4.0 mil glove graded for light tasks only. Compare the statement, not the number alone.
How long can a clinic keep a case before the lot ages out?
That comes from the manufacturer's instructions for use and the storage conditions, not from a Canadian rule. Heat and direct sunlight shorten the working life, so a storage area away from a radiator is part of compliance, not housekeeping.
Last updated: October 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).