Pulmonary Function Labs: Testing Supplies and Hygiene Routines
The spirometry room at a Canadian diagnostic clinic sees fifteen patients a day, from asthma follow-ups to pre-operative assessments. Each patient breathes into the same mouthpiece assembly, and each exhalation is a potential route for droplet transmission. Pulmonary function testing (PFT) creates a unique infection control challenge: the equipment is expensive, sensitive, and positioned directly at the patient's airway. The supplies around that equipment determine whether the lab stays safe, accurate, and compliant.
Quick facts: the PFT room in five lines
- A forced expiratory manoeuvre is aerosol-generating. It produces more droplets and aerosols than tidal breathing, which is why the spirometry room sits above routine practices alone.
- One circuit per patient. Mouthpiece, filter and nose clip are single use; anything reused follows the manufacturer's validated reprocessing instructions, including the named disinfectant and contact time.
- Surfaces are cleaned between patients, not once a day. Chair arms, the spirometer exterior and the counter beside it are the high-touch set.
- A wipe without its labelled contact time is a damp cloth. The kill claim belongs to the wet time, not to the motion.
- Filters run out first. A two-week buffer through respiratory season is what stops a technologist from testing without one.
Nitrile exam gloves for the testing room: CliniEco Medical Nitrile Exam Gloves — 3.5 mil, Standard Blue, 1,000 (Case).
Looking for the supplies in this guide? We stock them in Canada and ship from Toronto.
Biological indicators (24-hour, 25-pack) · Post-procedure repair masks (med spa) · Clinic supplies → · Wholesale & clinic accounts · Free sterilization log tool · Ask a compliance specialist
Products referenced in this guide
Why do PFT labs need their own hygiene rules?
Spirometry and related tests force patients to exhale forcefully, generating more droplets and aerosols than normal breathing. Professional societies have long recommended filters, regular equipment disinfection, and careful hand hygiene between patients. In Canada, the Public Health Agency of Canada's routine practices set the baseline for preventing transmission in clinical settings, and respiratory labs layer additional precautions beyond that baseline because of the aerosol-generating nature of the tests.
Which supplies at the point of testing are single use?
Mouthpieces, nose clips, and filters are the front line of PFT hygiene. Wherever the manufacturer and your infection control policy allow, use single-use items and discard them after each patient. For equipment that must be reused, such as the spirometer tubing in some systems, follow the manufacturer's validated reprocessing instructions, including the correct disinfectant and contact time.
Between patients, the surface where the patient places hands, the chair arms, and the counter beside the spirometer all need cleaning. Hospital-grade disinfectant wipes are practical for these surfaces. Choose a wipe with a DIN number and follow the label's stated contact time; a quick pass with a damp cloth does not disinfect.

Gloves and Hand Hygiene in the Testing Room
Technologists handle mouthpieces, filters, and contaminated equipment throughout the day. Powder-free nitrile gloves protect both the staff member and the next patient. Change gloves between patients and after any task that involves contact with respiratory secretions. Gloves are not a substitute for hand hygiene; the lab should have hand sanitizer at the door and sinks available nearby.
When stocking the PFT room, keep a box of nitrile exam gloves inside the room, not down the hall, so the technologist does not leave a patient mid-test to find a new pair. Multiple sizes matter: a glove that fits poorly reduces dexterity when assembling small filter pieces.

Cleaning Between Patients: A Practical Sequence
A consistent room turnaround routine keeps the lab safe without slowing the schedule:
- Remove and discard single-use mouthpiece, filter, and nose clips
- Wipe the spirometer exterior, chair arms, and counter with a disinfectant wipe
- Follow the labeled contact time before the next patient touches the surface
- Change gloves and perform hand hygiene
- Set up fresh single-use supplies for the next patient
Posters or a laminated checklist in the room help relief staff follow the same sequence. In a busy lab, the difference between a thorough turnaround and a rushed one is visible within a week of respiratory season.
Stocking for Accuracy and Safety
PFT results are only as reliable as the equipment calibration and the patient's effort, but supply shortages can still force unsafe shortcuts. Running out of filters is the classic failure: staff begin reusing filters or testing without them, which contaminates equipment and compromises results. Keep a two-week buffer of single-use items during respiratory season, and track usage so reorder happens before the box is empty.
For labs that also perform methacholine challenge or bronchodilator testing, the nebulizer cups and related disposables follow their own single-use rules. Individually wrapped surgical masks should be available for patients who are coughing or who need to leave the room mid-test, and for staff during aerosol-generating procedures.
Documenting Your Lab's Infection Control
Provincial regulators and accreditation bodies expect a written infection control policy for the PFT lab. Document the cleaning schedule, the products used (including DIN numbers), the reprocessing steps for reusable equipment, and the training record for staff. When an inspector asks how you prevent cross-contamination between patients, the answer should point to the policy, not to a vague habit.
Clinics monitoring every sterilizer load can start with the CliniEco biological indicator 5-pack trial: five 24-hour indicators for free with shipping included.
Pulmonary labs reprocess reusable items too. Mouthpieces, filters and spirometry hardware follow the maker's instructions for cleaning and reprocessing. The printable sterilization log sheet places the load, maintenance, malfunction and package-label records in one place; the same page carries a log and package-label generator builds a dated sheet you can print or export.
Have a question about your own facility? Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. Ask your compliance question.
How should a spirometry room be turned around between patients?
Most PFT lab policies describe the turnaround in prose, which is why relief staff improvise it. The table below splits the same routine into items, and each item names the supply that has to be in the room before the first patient sits down.
| Item in the turnaround | Single use? | Supply that has to be stocked | What the record shows |
|---|---|---|---|
| Mouthpiece, bacterial filter, nose clip | Yes, one per patient | Individually wrapped mouthpieces and filters, sized to the spirometer | Nothing beyond the visit, unless a filter lot is traced after an exposure |
| Spirometer exterior and patient-contact housing | No — cleaned | DIN-authorized disinfectant wipes at the labelled contact time | The cleaning schedule and the product used, by DIN |
| Reusable tubing or flow sensor | No — reprocessed | Manufacturer's validated reprocessing instructions | Reprocessing log for that unit |
| Chair arms, counter, door handles | No — cleaned | Disinfectant wipes or a labelled spray and cloth | Frequency in the room's cleaning policy |
| Hands and gloves between patients | Gloves: yes | Nitrile exam gloves in the room, in more than one size; hand hygiene at the door | Training record for staff |
| Patient with a cough or an active respiratory illness | — | Individually wrapped surgical mask for the patient, mask and eye protection for staff | Facility policy for additional precautions |
Two details make the table usable. The wipe's contact time is the pacing item, not the technologist's speed, so a room turnaround of two minutes only holds if the product's labelled time is shorter than that. And the reusable-tubing row is the one inspectors ask about, because it is the only line where the lab is claiming a reprocessed device rather than discarding a single-use one — Public Health Ontario's routine practices and additional precautions set the baseline those written procedures have to meet.
Where the lab also runs methacholine challenge or bronchodilator testing, the nebulizer cup and its tubing join the single-use list, and the turnaround picks up a second wait for the disinfection step on the dosing device. Keeping that equipment on its own tray, rather than sharing the spirometer cart, is what stops one room's turnaround from delaying the other.
Related Reading
- Dental Infection Control: Surface Disinfection Best Practices
- PHAC Routine Practices: How Canadian Clinics Apply the Guidelines
- CliniEco learning hub for clinic supply guides
Frequently Asked Questions
What supplies are needed for spirometry infection control?
Single-use mouthpieces, filters, and nose clips, plus gloves, disinfectant wipes for surfaces, and hand sanitizer. Reusable components are reprocessed according to the manufacturer's validated instructions.
How often should the spirometry room be cleaned?
High-touch surfaces should be cleaned between every patient. A full room cleaning, including floors and less-accessible surfaces, is typically done daily and whenever visible soiling occurs.
Do PFT labs need special masks?
Individually wrapped surgical masks are practical for patients who cough during testing and for staff performing aerosol-generating procedures. Mask requirements may be higher during respiratory outbreaks, following the facility's current policy.
Does a bacterial filter mean the spirometer never needs cleaning?
No. The filter sits at the patient end and captures what the patient exhales, which protects the tubing and the flow sensor from gross contamination. It does not clean the exterior housing the patient's hands and face touch, and it does not remove the need for hand hygiene and a glove change between patients. Treat the filter as one control in the chain rather than as the chain itself.
How many patients can a PFT room see before the schedule has to slow down?
The limit is set by the slowest step in the turnaround, which is usually the disinfectant's labelled contact time rather than the test itself. A lab that books patients back to back on a ten-minute cycle without checking that number ends up wiping a surface and putting the next patient on it while it is still wet, which is the failure mode an audit looks for. Time one real turnaround, including the wait, and book to that figure.
Last updated: September 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).