Par Levels for Saliva Ejectors: Step-by-Step Weekly Count

Aurelia saliva ejectors, white and clear single-use tips

Four chairs, twenty-two patients a chair-day, five days a week: a general practice in Mississauga goes through saliva ejectors faster than it goes through almost anything else it keeps in the operatory, and it does so invisibly. The ejector is picked out of a bag, used once and dropped in the waste, and the bag it came from sits in a drawer where nobody looks until it is empty. The Aurelia saliva ejectors, white, 100 per bag arrive in the format that makes this easy to fix, because the bag is the counting unit and the drawer is the shelf.

Counting suction tips is the simplest consumable count in a dental clinic and the one most often left undone, because there is no patient safety story attached to running short - the clinic simply stops between appointments and drives to a supplier. That workaround hides a cost that the sheet would show: unplanned pickups, split orders, and a per-unit cost that quietly rises. A par level turns the same purchase into one planned order a fortnight.

This guide gives the counting unit, the weekly count, the arithmetic that turns four weeks of counts into a reorder point, and the two record-keeping differences that matter when the clinic is buying in Canada and comparing what an American practice is asked for.

A saliva ejector par level, in six points

  • Count the bag, not the loose tip: the bag is the unit that gets opened, so it is the unit that gets counted and ordered.
  • One ejector is used per patient contact in a normal procedure, and the count should be measured against patient visits rather than against days.
  • Set the par as the weekly draw multiplied by the lead time plus one review week, plus one week of safety, then round to whole bags, counting in bags and ordering in whole 10-bag cases.
  • In the United States the ejector is a Class I device, exempt from premarket notification, filing under the dental operative unit and accessories regulation.
  • In Canada the article is a device distributed under an establishment licence; this catalogue is distributed under MDEL #35334.
  • Single use is the assumption on both sides of the border: the count exists to keep a fresh tip at every chair, not to ration a reusable one.

Aurelia saliva ejectors, white and clear single-use tips

The counting unit is the bag for a practical reason. A bag of one hundred is too many to count one at a time on a Friday afternoon and too few to last a busy practice a month, so it lands in the useful range: a clinic that counts bags can see a week of stock at a glance, and a clinic that counts loose tips will miscount by ten and discover it a day later. Bags are also the unit the order is written in, and because a case holds ten of them the order always lands on a whole case: the count is in bags, the purchase is in 10-bag cases of 1,000 ejectors, and both figures describe the same stock.

Aurelia saliva ejectors with blue connectors, supplied as single-use tips

What is a par level for saliva ejectors?

A par level is the quantity that has to be in the drawer on count day to get every chair through to the next delivery, plus a margin for the count being wrong. For a single-use tip the draw is close to the patient count, which makes the arithmetic more honest than it is for a product with a variable dose - there is no clinical judgement in how many tips a hygiene appointment uses.

Two adjustments stop the arithmetic from being too simple. The first is that not every appointment uses suction: a short check or a radiograph does not need an ejector, so the draw sits a little below the visit count rather than exactly on it. The second is that chair-side waste is real - tips dropped on the floor, a bag opened and found damaged, a tip that will not seat - and it belongs in the measurement rather than in a fudge factor at the end, which is why the count is measured weekly instead of predicted from the appointment book.

How do I count saliva ejectors at the weekly count?

Count sealed bags in the operatory drawers and the stock cupboard, and treat an opened bag as a fraction of one. A bag that is two thirds full counts as two thirds, and a bag with a handful of tips left counts as a tenth, because it will be finished inside the week anyway. Add the fractions to the sealed bags and the total is the stock in bags, which is the figure the par is written against.

Count where the tips are used. A practice that counts only the stock cupboard will report a comfortable number while three drawers sit open in the operatories; the same mistake in the other direction is a practice that counts the drawers and forgets the case behind the reception desk. The sheet should have a row per location: each operatory drawer, the hygiene cupboards, and the main store. For the four-chair practice in the example that is seven rows and takes under five minutes.

Write the count on the same day each week, ideally the day before the order cut-off, so that the number on the sheet is the number the order is placed against. A count taken on a Monday for an order placed on a Thursday will be three days stale by the time it is used, which at a draw of four bags a week is nearly half a bag of error.

How do I turn a week of counts into a reorder point?

Measure the draw over four weeks in bags. The four-chair practice sees 440 patient visits a week; at nine tips for every ten visits, plus waste, the draw lands at about four bags a week. That figure is measured from the count rather than derived from the appointment book, and the difference between the two is the correction the clinic applies to its own forecast from then on.

With a one-week lead time, a one-week review period and one week of safety, the par is twelve bags - three weeks of draw - which is 1,200 ejectors. A trigger at twelve bags is answered by ordering the par in full, and because the product ships ten bags to a case, twelve bags rounds up to two 10-bag cases - twenty bags. The shelf then holds thirty-two bags after delivery, eight weeks of draw at four bags a week, and the count falls back to the trigger five weeks later. That is the right shape for a product with no expiry pressure and a stable draw.

Chairs Visits a week Draw (bags a week) Par (3 weeks, bags) Order quantity at trigger (bags)
2 220 2 6 6
4 440 4 12 12
6 660 6 18 18

The table is written in bags because that is the counting unit; the order is placed in cases, and one case is ten bags, which is 1,000 ejectors. Six bags rounds up to one case, and both the twelve-bag and eighteen-bag rows round up to two cases, twenty bags.

The six-chair row is where practices usually under-order. At a draw of six bags a week the par of eighteen bags is three weeks of stock, and an order that rounds the par down carries the shelf straight back below the trigger, so the clinic re-orders a week later. Ordering the par in full is ordered as two 10-bag cases - twenty bags - which puts the shelf at thirty-eight bags, a little over six weeks at this draw, and lets the count fall for a little over three weeks before it triggers again, which is the rhythm the par was designed to produce.

The same two units carry across the other suction line: Aurelia HVE tips, white, 100 tips per bag are counted in bags and bought in the same 10-bag case, so one sheet, one par and one order rhythm can cover both tips without a second set of arithmetic.

How do the Canadian and American rules change what a dental clinic records?

Both markets treat the ejector as a low-risk device, and both expect it to be used once. Queried through the openFDA device classification database on 24 November 2026, the product codes that cover a saliva ejector mouthpiece and an oral cavity evacuator are Class I, exempt from premarket notification, and file under 21 CFR 872.6640, the regulation for a dental operative unit and its accessories. In Canada the same article is a device under the Medical Devices Regulations, sold by a licensed establishment: the distributor's MDEL number is the document a clinic can verify, and this catalogue is distributed under MDEL #35334.

The recording difference is more practical than regulatory. An American practice is used to citing a product code when a question arises about what a device is; a Canadian practice is used to citing a licence number for the seller. Neither practice is asked to keep a per-unit certificate for an ejector, and both are asked to be able to show that single-use items were used once - which is a statement about the clinic's own routine, supported by the count sheet and the purchase record rather than by a document from the manufacturer.

Item Canada United States
Regulatory route Device under the Medical Devices Regulations, sold by a licensed establishment Class I device, exempt from premarket notification
Number a clinic can verify MDEL of the importer or distributor, for example MDEL #35334 Product code and 21 CFR 872.6640
Single-use expectation Provincial infection prevention guidance for dental settings CDC dental infection control guidance and the bloodborne pathogens standard
Reprocessing information Manufacturer's instructions required under ISO 17664-1 where the item is reusable Same, with the standard cited in the clinic's exposure control plan
Counting unit in practice Bag of 100 Bag of 100

Nothing in that table changes the arithmetic, and everything in it changes what the clinic files when the order arrives. The purchase record, the bag label and the count sheet should agree on the same three strings: the product, the pack size and the lot. A clinic that can produce those three on request has answered the only question an auditor asks about a single-use consumable.

What should the count sheet record each week?

Date, location, sealed bags, fraction of the open bag, total in bags, and the lot on the case behind the stock. When the total reaches the par, add the order quantity and the date ordered, so that the next count reconciles against the delivery instead of guessing whether the order was placed. Two lines at the foot of the sheet - the par and the measured weekly draw - keep the sheet usable by whoever is counting.

The location column earns its place the first time a drawer runs out. Draws are not uniform: a surgical operatory uses more suction than a hygiene room, and the drawer next to the assistant's station empties faster than the one behind the door. A sheet with rows per location shows which drawer needs its own par, and that is a small change with a visible effect on the number of mid-week trips to the store cupboard.

When should the par level change?

Four events. Adding a chair changes the draw and should change the par in the same week. Changing the appointment mix toward surgery raises the tips per visit. A move to a different bag size - 100 to a bag is the format here, but suppliers vary - changes the unit and therefore the whole calculation. The fourth is a change of suction equipment, because a new delivery system that needs a different tip connector changes the product before it changes the count.

Where a practice wants the count to survive staff changes, the arithmetic is worth writing on the sheet: draw times three, rounded to bags, ordered in bags. The dental clinic supply range lists the pack sizes for the suction consumables, so the par, the order and the product page all describe the same unit. For multi-site groups the institutional and wholesale account enquiry handles account set-up, and practices that want the suction and instrument routines checked against their own infection prevention manual can use the sterilization and infection control consultation route. The compliance log centre carries the printable log generator used for the weekly count. Reselling? become a distributor.

References

Related Reading

Frequently Asked Questions

How often should the saliva ejector count be done?

Weekly, the day before the order cut-off. A weekly count matches the review period in the par calculation, so a drawer that reaches par the day after a count still has a week of stock before the next trigger.

Should an opened bag be counted as a full bag?

No. Count the fraction that is left, because the opened bag is the one that will run out mid-week. Treating it as full is the most common reason a practice runs dry on a Friday afternoon.

Is one ejector per patient the right planning figure?

It is the starting point, not the answer. Short checks and radiographs use none, waste adds a few, so the measured draw usually lands just below the visit count. Measure four weeks and use the measured figure.

Do saliva ejectors need to be sterile?

They are supplied as clean single-use items, not as sterile items, and they are used once and discarded. The clinic's obligation is that a fresh item is available at every chair and that used ones go into the waste stream the practice has set up.

What licence should a Canadian clinic ask for?

The establishment licence of the importer or distributor, which is an MDEL. This catalogue is distributed under MDEL #35334. A per-unit licence does not exist for this category in either country.

What is the US classification for this product?

The ejector mouthpiece and the oral cavity evacuator are Class I, exempt from premarket notification, under 21 CFR 872.6640. A US buyer is given a product code rather than a clearance number.

Figures in this article are planning and troubleshooting references, not clinical, legal or regulatory advice, and they do not replace the sterilizer or washer-disinfector manufacturer's instructions for use. Requirements quoted here were published as described at the time of writing and are amended from time to time, so confirm them against the instruments in force for your jurisdiction. CliniEco Medical distributes medical consumables under MDEL #35334.