Inoculation & Culture

This collection carries the sterile 100 × 15 mm polystyrene culture dish, supplied empty and sold by the case of 500 for laboratories that pour their own medium. Colony counts, streak plates for isolation and settle or contact plates for air and surface sampling all run on the same format, so one case on the shelf covers three bench methods. No agar, no additives and no pouring step are included: the medium stays with the method the laboratory has already validated.

5 products
More about Inoculation & Culture

The item described on this page is the sterile 100 × 15 mm polystyrene petri dishes, 500 per case, item code CLI-PETRI-100. Everything below refers to that code and to what one case does and does not settle.

What is a 100 × 15 mm sterile petri dish, and what does a case contain?

A 100 × 15 mm dish is round and shallow, moulded in optically clear polystyrene, 100 mm across and 15 mm deep, supplied sterile and empty. Each dish is two pieces, a base and a loose lid, and the lid on this listing is vented so that air moves between the dish and the incubator. One case holds 500 dishes.

The format gives a growth surface of about 69 cm² and fits standard incubator shelves without overhanging. Because the lid is vented the dish is not designed for stacking, so plates sit flat rather than in a pile.

100 × 15 mm polystyrene dish: the numbers a purchasing officer needs before ordering
Item Detail
Format 100 mm diameter × 15 mm depth
Material Polystyrene, optically clear, single use
Lid Vented, for gas exchange
Growth area About 69 cm²
Agar at 3 mm depth About 21 mL
Typical pour volume 15–20 mL per dish
Pack configuration 500 dishes per case
Item code CLI-PETRI-100
Case price, price as of 2026-11-23 CAD $159.99, about 32 cents a dish
Stacking Not designed for stacking, vented lid

Which bench methods does one plate format cover?

Three. Colony counts, where each visible colony is read as one colony-forming unit from the dilution that was plated. Streak plates for isolation, where the 100 mm surface divides into enough sectors for a loop to be drawn through successive quadrants until single colonies appear. And environmental sampling, where an open settle plate or a pressed contact plate is incubated and counted exactly like any other plate.

That overlap argues for keeping one diameter on the shelf: a laboratory buying several sizes stores several cartons and checks their lot references.

How much agar does a 100 × 15 mm dish take?

Depth sets the pour, not volume: about 3 mm of medium. Over the roughly 69 cm² growth area that works out to about 21 mL, and most methods pour between 15 mL and 20 mL as long as the layer is even across the whole surface. A case of 500 dishes at a 20 mL pour takes about ten litres of prepared medium.

Holding the depth constant matters because it changes a count without anything being wrong with the sample. A thin pour dries at the rim during long incubation and edge colonies stop developing; a thick pour holds condensation under the lid and moves colonies out of the plane a counter is focused on.

What does a case of 500 cost, and what is the per-dish figure?

The case is CAD $159.99, price as of 2026-11-23, which puts one dish at about 32 cents: 159.99 divided by 500 is 0.32. The per-dish figure is arithmetic on the case price rather than a second price schedule, and it is the number to carry into a media and plate budget.

Weekly usage, not case size, decides how many cases to hold. A laboratory plating 100 dishes a week holds about five weeks of supply in one case; at 250 dishes a week the same case lasts a little over one week. Four to six weeks of cover, reviewed against actual usage, keeps a run from waiting on a plate.

What should be confirmed before the case is ordered?

Four things. That the written method names 100 × 15 mm rather than 90 mm or 60 mm, because a procedure validated on one diameter is not automatically equivalent on another. That a vented lid suits the incubation, since a sealed plate is a different set-up. That the laboratory pours its own medium. And that the dish fits the counter carrier or incubator shelf it will occupy.

Two limits belong in the same check: polystyrene is single use and deforms at autoclave temperatures, so glass is the reusable option where the workflow is heat based, and a larger dish spends more medium per test, so the size that lands the count inside the readable range with the fewest plates per sample is the cheaper one to run.

How should the case be stored, labelled and lot-tracked?

Keep the sleeve closed until the dishes are needed, work from one sleeve at a time, and never return an opened dish to it, because a lid that has been off on a bench is no longer sterile. Label the base rather than the lid, since lids get swapped. Record the lot reference from the case when it is opened, and keep it with the plate records.

Prepared plates are stored inverted at 2–8 °C, brought back to room temperature before use and used oldest first by the date written on the base. On arrival, check case and sleeve counts against the packing document and that the lot reference on the cartons matches the one on the sleeves.

Plate and medium volumes can be modelled on the clinic supply and cost planner, and culture and media-preparation templates print from the compliance log centre. For the multiplier that decides how many plates a bench actually needs, our guide to how many petri dishes a Canadian diagnostic microbiology laboratory uses per week works through the arithmetic case by case.

This item is ordered in whole cases, which is the unit the purchase order is written in, and the lot reference on the carton is the field to keep with the order record. Delivery timing is confirmed against stock when the order is placed; for standing orders and volume terms, request a quote before the first case goes on the shelf.