How Many Class 5 Chemical Integrators Does a Dental Hygiene Clinic in Quebec Use per Month, and How Many 200 per Pack Boxes Is That? One Strip per Load

CliniEco Class 5 steam chemical integrator specification card, ISO 11140-1 Type 5, 121 to 135 degrees C

How Many Class 5 Chemical Integrators Does a Dental Hygiene Clinic in Quebec Use per Month, and How Many 200 per Pack Boxes Is That? One Strip per Load

Quebec counts the Class 5 integrator per load, not per package, and that one distinction decides whether a hygiene clinic buys four strips a month or ninety. The province puts the type 5 strip in the load's test device; the package carries a different pair of indicators.

The strip priced here is the CliniEco steam chemical integrator - Class 5, ISO 11140-1 Type 5, 200-strip pack, yellow-to-black read with anClass 5 steam chemical integrator, 200 strips to a pack, case of five packs.

How many Class 5 integrators does a Quebec hygiene clinic use in a month?

One per load, plus the weekly verification. Four loads a day across 21 working days is 84 loads, so 84 integrators. The weekly test pack for each sterilizer and each cycle type adds about five more, and those cannot share a cycle with the daily air-removal test on a class B machine. Ninety a month is the planning figure; 1,080 a year is six 200-strip packs.

CliniEco Class 5 steam chemical integrator specification card, ISO 11140-1 Type 5, 121 to 135 degrees C

Loads a day Loads a month Load integrators Weekly test packs Total a month 200-packs a year
2 42 42 5 47 3
4 84 84 5 89 6
6 126 126 5 131 8

Where does the type 5 strip go in a Quebec load?

Into the process challenge device, placed at the point the sterilizer manufacturer identifies as hardest to sterilize, and checked when the cycle ends. The indicators that go inside the packages are a separate requirement: type 1 outside and type 4 inside every package. A clinic that budgets type 5 strips per package instead of per load inflates the order several times over, which is the most common counting error we see in Quebec par-level sheets.

Six 24-hour biological indicators arranged in two rows

How many 200-per-pack boxes does that make in a year?

Six at four loads a day: 1,080 strips against 1,200 in six packs, with 120 spare. At two loads a day three packs cover the year and leave 36 strips over. The spare matters more than it sounds, because the pack has a printed expiry date and an unopened pack left near a warm sterilizer does not keep as long as one kept in a dry drawer.

Does the weekly biological test change the order?

It adds a second line rather than replacing the first. The weekly device holds a 24-hour self-contained biological indicator alongside a type 5 strip, inside a pouch, so three consumables move together on the same test: the Class 4 dual-indicator pouch, the strip and the vial. A clinic that loads the device with a plain pouch and no indicator has the paperwork of a test and none of the evidence.

Running a dental practice? See our dental practice sterilization and hygiene supplies. Clinics that want the load-release record checked before an inspection can ask a specialist at our sterilization compliance desk.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. Ordre des dentistes du Québec, Prévention et contrôle des infections et retraitement des dispositifs médicaux, revised February 2026 (checked 16 November 2026)
  2. ISO 11140-1:2014, Sterilization of health care products, chemical indicators, general requirements (checked 16 November 2026)
  3. CSA Z314:23, Canadian medical device reprocessing in all health care settings (checked 16 November 2026)
  4. ISO 11138-1:2017, Sterilization of health care products, biological indicators (checked 16 November 2026)

Printable companion: the compliance log center carries a load log with one row per cycle, which is the record that proves a Class 5 strip went into the load rather than into the box.

Working from loads rather than invoices? The sterilization monitoring usage calculator converts loads per day and cycle types into strips per month before an order is placed.

Related Reading

Frequently Asked Questions

How many Class 5 integrators does a Quebec hygiene clinic use in a month?

About ninety at four loads a day: 84 for the loads themselves across 21 working days, plus roughly five from the weekly test pack.

Is the Class 5 integrator a per-package or per-load item in Quebec?

Per load. The ODQ guidelines place a process challenge device with a type 5 indicator in each load; the indicators inside packages are type 1 outside and type 4 inside.

How many 200-per-pack boxes is that in a year?

Six. 1,080 strips a year against 1,200 in six packs leaves 120 spare, which is the buffer for a month with extra loads.

Does the weekly biological test use the same strip?

No. It pairs a biological indicator with a type 5 indicator inside one test pack, and that pack cannot share a cycle with the daily air-removal test.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Already working with clinics? Become a regional representative.