MTC Bio Filtered 200 and 300 microlitre Pipette Tips, Sterile, Racked
Specifications
| SKU | CLI-TIP-200-STD-F-P4300-FT |
|---|---|
| Brand | MTC Bio |
| Category | Laboratory Consumables |
| Availability | In stock |
| Ships from | Toronto, ON |
Pricing
| Order | Unit price |
|---|---|
| 1 unit | $799.76 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 8 sections · specs, use, compliance
MTC Bio sterile filtered pipette tips for 200 and 300 microlitre pipettes, with a hydrophobic barrier, 960 tips per pack and 4,800 per case, shipped from North American stock.
A filter does one job: it stops aerosol and liquid travelling between the sample and the pipette barrel. That matters for PCR, for anything that could carry over between samples, and for the pipette itself, because a barrel that has drawn sample is a barrel that has to be serviced. These are filtered 200 and 300 microlitre tips, sterile, racked in 96-position boxes.
What is in a case of filtered tips?
A pack holds 960 tips in 10 racks of 96, and a case holds five packs, so 4,800 tips in 50 racks. Racks are sealed in a sleeve of ten, so a bench can open one sleeve at a time and keep the rest sterile.
The case count is the same as the non-filtered version, which makes substitution a price decision rather than a storage decision: the rack footprint does not change when the filter is added.
A sleeve of ten racks is enough for a working week at one plate a day, so a case covers about ten weeks of single-plate work and a bench can reorder on the sleeve rather than the case.
When is a filter required rather than optional?
For PCR and qPCR it is effectively required: an aerosol that reaches the barrel will contaminate the next sample, and the resulting band is the kind of false positive that costs a day to chase. For cell work and for any step that handles a clinical sample, a filter protects the operator's pipette as much as the sample.
For clean reagent transfer with a single stock solution, a non-filtered tip is adequate and cheaper. The decision is about carryover risk, not about tip quality: the same manufacturer makes both, and the filter is the variable.
There is also a service argument for the filter: a pipette barrel that has drawn sample needs a service visit, and the downtime usually costs more than a year of filtered tips for the same bench.
What are the specifications of the filtered 200 microlitre tip?
Every configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.
| Configuration | Manufacturer reference | Pack | Case |
|---|---|---|---|
| Pipette Tips · Filtered · 300µL capacity · sterile · for 200µL and 300 | P4300-FT | 960 per pack | 4,800 per case |
How many filtered tips does a PCR lab use?
A lab running four 96-well plates a week with a fresh tip per well uses 384 tips a week, about 1,650 a month, so a 4,800-tip case lasts three months. Where tips are changed between reagents in the same well, consumption rises two to three times.
Because filtered tips cost more per tip than standard ones, most labs use them for the PCR bench only and keep standard tips for reagent handling: two racks of filtered tips and a case of standard tips is the usual split.
Where a lab runs both PCR and clean reagent work, the filter cost belongs to the PCR line in the budget, not to the tips line: keeping the two counts separate is what makes the filtered tip spend visible.
A bench that runs plates twice a week rather than daily should size against the week, not the year, because racks take shelf space either way.
| Working pattern | Used per month | Case covers |
|---|---|---|
| One bench, light use | about 300 pieces | roughly 8 months |
| One bench, full shift | about 2,000 pieces | roughly 2 months |
| Two benches | about 4,000 pieces | under one month |
Counts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.
How is it shipped, and what should you check on arrival?
Tips ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. Racks are sealed and the case label carries the manufacturer reference and lot.
Check that the filter sits at the collar and is not pushed into the tip: a filter that has moved will reduce the volume a tip can hold, and it is the one defect that is visible before use.
If a rack has been opened and left on the bench for a week, treat it as non-sterile for PCR and start a sealed rack for the next plate run.
Filtered racks are also the item a shared bench borrows most often, so keep one rack in a marked sleeve per bench rather than a single open rack for the room.
What we do not claim
Single-use laboratory consumables for pipetting. Not sold as medical devices for patient treatment. Filter presence, sterility and orifice size are the manufacturer's stated values; the tip is not a calibrated measuring device.
What we cannot do is certify a filter for a specific aerosol challenge: send the application and we will check the manufacturer's documentation rather than assume a barrier is absolute.
Frequently asked questions
How many tips per case?
960 tips per pack in 10 racks of 96, five packs per case, so 4,800 tips in 50 racks.
What does the filter stop?
A hydrophobic barrier that prevents aerosol and liquid from reaching the pipette barrel; it is not a sterile filter for the sample itself.
Do filtered tips fit the same pipettes as standard tips?
They are made for the same 200 and 300 microlitre pipettes; the filter changes the internal volume slightly, so check the low end of the range if your protocol uses volumes under 10 microlitres.
Are they sterile?
Yes, this configuration is sterile and racked; the rack is sealed until opened.
Can I use filtered tips for cell culture?
Yes, and they are the usual choice where carryover between samples would be a problem; confirm the sterility on the lot documentation for your quality file.
Choosing the right option
Related products in the same laboratory line:
- clinieco cli tip 200 std n pipette tips
- mtc bio sureseal s 1 5ml sterile microcentrifuge tubes 500 pack
Background reading before you order:
Common questions
How many tips per case?
960 tips per pack in 10 racks of 96, five packs per case, so 4,800 tips in 50 racks.
What does the filter stop?
A hydrophobic barrier that prevents aerosol and liquid from reaching the pipette barrel; it is not a sterile filter for the sample itself.
Do filtered tips fit the same pipettes as standard tips?
They are made for the same 200 and 300 microlitre pipettes; the filter changes the internal volume slightly, so check the low end of the range if your protocol uses volumes under 10 microlitres.
Are they sterile?
Yes, this configuration is sterile and racked; the rack is sealed until opened.
Can I use filtered tips for cell culture?
Yes, and they are the usual choice where carryover between samples would be a problem; confirm the sterility on the lot documentation for your quality file.