MTC Bio Exact Volume Transfer Pipettes — E9500-20

MTC Bio Exact Volume Transfer Pipettes, 20 to 500 microlitre, Sterile Bags

SKU CLI-TPIP-X-E9500-20 · MTC Bio
$3,834.65$4,229.90
In stock · ships from Toronto, ON
Exact Volume Transfer Pipette · 20uL · 53mm · sterile · 10 resealable bagsconfiguration
10configuration options
CLI-TPIP-X-E9500-20sku
Laboratory Consumablescategory
Configuration · 10 options
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping over $99 in Ontario · $199 rest of Canada

Specifications

SKUCLI-TPIP-X-E9500-20
BrandMTC Bio
CategoryLaboratory Consumables
AvailabilityIn stock
Ships fromToronto, ON

Pricing

OrderUnit price
1 unit$3,834.65 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 8 sections · specs, use, compliance

Sterile exact volume transfer pipettes from 20 to 500 microlitre, ten fixed volumes with matched stem lengths, in resealable bags of 1,000 to 5,000, shipped from North American stock.

An exact volume transfer pipette has a bulb moulded to one volume, so the draw stops at that volume and the operator does not have to watch a graduation. This range runs from 20 microlitre at 53 mm to 500 microlitre at 120 mm, with the stem length matched to the volume, so a lab can hold one tool per volume instead of one pipette with a printed scale. All configurations are sterile and bagged in resealable bags.

What is in a bag of exact volume pipettes?

The 20 microlitre configuration holds 5,000 pipettes in 10 resealable bags, so 500 per bag across a 10-bag case. The 50, 80, 100, 150, 200 and 250 microlitre configurations hold 2,500 in five bags, and the 300, 400 and 500 microlitre configurations hold 1,000 in two bags.

Volume decides the bag count because the bulb grows with the volume: a 500 microlitre bulb takes roughly ten times the shelf space of a 20 microlitre one, so the case is smaller for the larger volumes.

How do you pick the volume, and when is exact volume worth it?

Exact volume earns its price where a step depends on a repeatable small volume and a pipettor is either unavailable or slower than the task: adding a fixed reagent to a strip, inoculating a fixed volume into broth, transferring a stain. The 20 to 100 microlitre range covers most of those steps, and the 150 to 500 microlitre range covers bulk reagent additions.

Stem length tracks volume: 53 mm for 20 microlitre, 72 mm for 50, 96 to 100 mm through 80 to 200, and 113 to 120 mm for 250 to 500. A short stem on a large volume gives the bulb a shorter drop, which is what keeps a 500 microlitre transfer controllable.

What are the specifications?

Every configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.

Configuration Manufacturer reference Pack Case
Exact Volume Transfer Pipette · 20uL · 53mm · sterile · 10 resealable E9500-20 5,000 per pack 50,000 per case
Exact Volume Transfer Pipette · 50uL · 72mm · sterile · 5 resealable b E9500-50 2,500 per pack 12,500 per case
Exact Volume Transfer Pipette · 80uL · 96mm · sterile · 5 resealable b E9500-80 2,500 per pack 12,500 per case
Exact Volume Transfer Pipette · 100uL · 86mm · sterile · 5 resealable E9500-100 2,500 per pack 12,500 per case
Exact Volume Transfer Pipette · 150uL · 100mm · sterile · 5 resealable E9500-150 2,500 per pack 12,500 per case
Exact Volume Transfer Pipette · 200uL · 100mm · sterile · 5 resealable E9500-200 2,500 per pack 12,500 per case
Exact Volume Transfer Pipette · 250uL · 113mm · sterile · 5 resealable E9500-250 2,500 per pack 12,500 per case
Exact Volume Transfer Pipette · 300uL · 113mm · sterile · 2 resealable E9500-300 1,000 per pack 2,000 per case
Exact Volume Transfer Pipette · 400uL · 115mm · sterile · 2 resealable E9500-400 1,000 per pack 2,000 per case
Exact Volume Transfer Pipette · 500uL · 120mm · sterile · 2 resealable E9500-500 1,000 per pack 2,000 per case

How many exact volume pipettes does a bench use?

A bench doing 40 fixed additions a day uses 40 pipettes, about 850 a month, so a 2,500-pipette case of one volume lasts three months. Where a protocol uses three volumes, the consumption splits across three cases, and the reorder point should be set per volume rather than for pipettes as a class.

Because these are single-volume tools, a bench that changes protocol often ends up with several part-used cases; label each bag with the volume on the outside so a bag is not opened twice for the same step.

Working pattern Used per month Case covers
One bench, light use about 300 pieces roughly 8 months
One bench, full shift about 2,000 pieces roughly 2 months
Two benches about 4,000 pieces under one month

Counts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.

How is it shipped, and how should it be stored?

Pipettes ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. Each resealable bag carries the manufacturer reference and lot.

Reseal the bag after each use and store flat: a bulb that has been compressed under a carton will not return to its moulded volume, and a pipette that is off volume is worse than no pipette at all.

What we do not claim

Single-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. The volume is a nominal moulded value rather than a calibration; sterility is the manufacturer's stated value per configuration.

What we cannot do is certify the delivered drop of a moulded bulb: if a step needs a tolerance tighter than the moulded volume, send us the tolerance and we will say whether this range fits.

Frequently asked questions

How many pipettes per case?

20 microlitre holds 5,000 in 10 bags of 500; 50 to 250 microlitre hold 2,500 in five bags; 300 to 500 microlitre hold 1,000 in two bags.

Is the volume exact?

The bulb is moulded to the stated volume so the draw stops there; it is a nominal value rather than a calibration, and delivered volume depends on how the pipette is held.

Are these pipettes sterile?

Yes, all configurations on this page are sterile and packed in resealable bags with the lot on the bag.

Which volume should a general bench keep?

20, 100 and 200 microlitre cover most fixed additions; add 500 microlitre only if a bulk reagent step needs it.

Can an exact volume pipette replace a pipettor?

For a fixed volume, often yes; for variable volumes or for a measured transfer into a calibrated vessel, a pipettor or a graduated pipette remains the right tool.

Choosing the right option

Related products in the same laboratory line:

Background reading before you order:

Laboratory consumables

Common questions

How many pipettes per case?

20 microlitre holds 5,000 in 10 bags of 500; 50 to 250 microlitre hold 2,500 in five bags; 300 to 500 microlitre hold 1,000 in two bags.

Is the volume exact?

The bulb is moulded to the stated volume so the draw stops there; it is a nominal value rather than a calibration, and delivered volume depends on how the pipette is held.

Are these pipettes sterile?

Yes, all configurations on this page are sterile and packed in resealable bags with the lot on the bag.

Which volume should a general bench keep?

20, 100 and 200 microlitre cover most fixed additions; add 500 microlitre only if a bulk reagent step needs it.

Can an exact volume pipette replace a pipettor?

For a fixed volume, often yes; for variable volumes or for a measured transfer into a calibrated vessel, a pipettor or a graduated pipette remains the right tool.