MTC Bio DeepDip 1500 microlitre Filtered Tips — P4331

MTC Bio DeepDip 1500 microlitre Filtered Tips, Extra Length 130 mm — Sold by the Case

SKU CLI-TIP-X-STD-F-P4331 · MTC Bio
$91.90$101.99
In stock · ships from Toronto, ON
DeepDip™ Pipette Tips · 1500µL Capacity · Extra Length · 130mm · Filtered,configuration
CLI-TIP-X-STD-F-P4331sku
Laboratory Consumablescategory
MTC Biobrand
Pack sizeDeepDip™ Pipette Tips · 1500µL Capacity · Extra Length · 130mm · Filtered, Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping over $99 in Ontario · $199 rest of Canada

Specifications

SKUCLI-TIP-X-STD-F-P4331
BrandMTC Bio
CategoryLaboratory Consumables
AvailabilityIn stock
Ships fromToronto, ON

Pricing

OrderUnit price
1 unit$91.90 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 8 sections · specs, use, compliance

DeepDip 1500 microlitre extra-length filtered tips at 130 mm with a hydrophobic barrier, 480 tips per pack, shipped from North American stock.

The filtered version of the DeepDip tip exists for the case where reach and carryover both matter: taking a sample from the bottom of a 50 mL tube in a workflow where aerosol must not reach the pipette barrel. The 130 mm length solves the reach problem, the filter solves the carryover problem, and both are needed when the sample is a clinical or a molecular one.

What is in a pack of filtered DeepDip tips?

480 tips per pack, 1500 microlitre capacity, 130 mm length, with a hydrophobic filter at the collar. The pack is the working unit, because the format is used for a specific step rather than for general pipetting.

Because the filter adds a component, the tip is the highest-cost format on this part of the range; a lab that only needs reach can use the non-filtered version instead.

The pack also carries the lot on the outside, which is the reference a quality file needs when the step is part of a validated method.

A single pack is also the right first order for a lab that has not used the format before.

When is the filter necessary with an extra-length tip?

When the sample is taken from depth and could splash or aerosolise: a resuspension at the bottom of a tube, a sample that has been vortexed, a viscous material that releases droplets when the tip is withdrawn. A long tip puts the orifice close to the material, which is exactly where aerosol forms.

When the sample is clean and the vessel is simply deep, reach is the only requirement and the non-filtered tip is adequate. The decision is about what happens at the moment of aspiration, not about the length.

A practical check before a validated run: draw a sample of water from the bottom of a tube and watch for bubbles at the collar. Bubbles mean the filter or the seal is not seated, and a run started with that tip will show a low volume.

Because the tip reaches further than the pipette shaft, the operator holds the pipette more upright than with a standard tip, and a bench should practise this on water before a validated sample.

What are the specifications?

Every configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.

Configuration Manufacturer reference Pack Case
DeepDip™ Pipette Tips · 1500µL Capacity · Extra Length · 130mm · Filte P4331 480 per pack 480 per case

How many filtered DeepDip tips does a bench use?

A bench taking 20 samples a day from deep tubes uses 20 tips, about 420 a month, so a 480-tip pack lasts about five weeks. Where the step runs twice a week, one pack lasts a quarter.

Keep this pack next to the instrument that needs the reach, and keep a note of the pack count on the bench: a substituted standard tip will not reach, and the operator will notice only when the pipette shaft touches the tube.

Where a bench uses the format daily, a case of packs is the sensible order; where it uses it monthly, a single pack is enough and the money is better spent on the standard tip that carries the bulk of the work.

A bench that runs the step weekly should keep one pack and reorder at half a pack: a full case is a storage decision, and this format is used by the step rather than by the day.

Working pattern Used per month Case covers
One bench, light use about 300 pieces roughly 8 months
One bench, full shift about 2,000 pieces roughly 2 months
Two benches about 4,000 pieces under one month

Counts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.

How is it shipped, and what should you check first?

Tips ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses, with the reference and lot on the pack.

Check that the filter is seated at the collar and that the tip is straight: at 130 mm a bent tip is visible, and a bent tip will not reach the bottom of a narrow tube.

Keep the pack closed between sessions: at 130 mm the tips protrude from a rack, and a protruding tip collects dust on the outside of the shaft, which then enters the vessel.

If a tip is dropped, discard it: at 130 mm the fall is enough to bend the shaft, and a bent tip will not reach the bottom of a narrow tube.

What we do not claim

Single-use laboratory consumables for pipetting. Not sold as medical devices for patient treatment. Length, filter presence and sterility are the manufacturer's stated values; the tip is not a calibrated measuring device.

What we cannot do is certify the filter against a specific aerosol requirement: send the requirement and we will check the manufacturer documentation.

Frequently asked questions

What is the difference from the non-filtered DeepDip?

The filter: the non-filtered version gives reach only, the filtered version gives reach plus a barrier against aerosol reaching the pipette barrel.

How long is the tip?

130 mm, with a 1500 microlitre capacity.

How many tips per pack?

480 tips per pack, which is the working unit for a step used once or twice a week.

Will it fit a 1000 microlitre pipette?

It fits pipettes that accept the 1000 microlitre tip family; confirm the model, because the extra length changes how the tip sits.

Can I substitute a standard filtered tip?

Only if the standard tip reaches your vessel; where reach is the reason for the format, a substitution will leave sample behind.

Choosing the right option

Related products in the same laboratory line:

Background reading before you order:

Laboratory consumables

Product line: MTC Bio DeepDip 1500 microlitre Filtered Tips, Extra Length 130 mm
Manufacturer reference: CLI-TIP-X-STD-F-P4331
Ships from: North American stock
Sold by: the case

Common questions

What is the difference from the non-filtered DeepDip?

The filter: the non-filtered version gives reach only, the filtered version gives reach plus a barrier against aerosol reaching the pipette barrel.

How long is the tip?

130 mm, with a 1500 microlitre capacity.

How many tips per pack?

480 tips per pack, which is the working unit for a step used once or twice a week.

Will it fit a 1000 microlitre pipette?

It fits pipettes that accept the 1000 microlitre tip family; confirm the model, because the extra length changes how the tip sits.

Can I substitute a standard filtered tip?

Only if the standard tip reaches your vessel; where reach is the reason for the format, a substitution will leave sample behind.