Sterile Petri Dish 100 × 15 mm — Polystyrene, 500/Case
Ships to Canada only
Specifications
| SKU | CLI-PETRI-100 |
|---|---|
| Brand | CliniEco Medical |
| Category | Laboratory Consumables |
| Availability | In stock |
| Ships from | Toronto, ON |
Pricing
| Order | Unit price |
|---|---|
| 1 unit | $114.00 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 15 sections · specs, use, compliance
Case of 500, supplied sterile and empty, so each lab pours the medium it has already validated. Once a plate has been read it leaves as biohazard waste, which is why the bench set-up usually includes red 30-gallon biohazard waste bags, 5 per pack alongside the dish itself.
What is a 100 × 15 mm sterile petri dish used for?
A 100 × 15 mm petri dish is a round, shallow polystyrene dish measuring 100 mm across and 15 mm deep, supplied sterile and empty so that the laboratory pours a medium it has already validated. The format is two pieces: a base and a loose lid. That is what makes it workable on an open bench — the lid shields the agar surface while the plate is carried and read, and it can be lifted for inoculation without the dish being handled by the agar.
Three kinds of work account for most of the volume a laboratory buys. Colony counts come first: in a pour plate or a spread plate each visible colony is read as one colony-forming unit from the dilution that was plated, so the useful thing about the dish is that it presents a flat, uniformly deep layer of medium that can be counted without parallax. Streak plates for isolation come second: the 100 mm surface divides into enough sectors that a loop can be drawn through successive quadrants and single colonies recovered from the last one. Air and surface sampling come third: a settle plate is left open for a fixed time in a room, and a contact plate is pressed onto a bench or a surface, and both are then incubated and counted the same way as any other plate.
The 100 mm diameter is the general-purpose size. It fits the stage or carousel of most automatic colony counters, it sits flat inside standard incubator racks and plate towers without overhanging the shelf, and it is the format that the largest number of written procedures name. For a laboratory that runs more than one method, that means one diameter on the shelf instead of several bought for occasional work.
Two limits are worth stating plainly, because they decide whether this is the right dish at all. It is polystyrene, so it is single use: polystyrene deforms at autoclave temperatures, and glass is the reusable option where a workflow is heat based. And it is sold empty — the medium, the additives and the pouring step belong to the laboratory's own procedure, not to the dish.
What does one 100 × 15 mm plate cost in a case of 500?
A case is $102.39 for 500 dishes, so one plate lands at about 20 cents: 102.39 divided by 500 is 0.20478. That is the number a plant or water laboratory needs when it costs a sampling programme, because a plate count series consumes dishes by the dozen before any incubation time is booked. The case price is the current price on this listing; the per-plate figure is arithmetic on it rather than a second price schedule, and it holds for every method that uses the same 100 × 15 mm format.
Parameter: Detail
Dimensions: 100 mm diameter × 15 mm height
Material: Polystyrene, optically clear
Lid: Vented, for gas exchange
Sterility state: Sterile, single use
Stacking: Not designed for stacking (vented lid)
| Parameter | Detail |
|---|---|
| Dimensions | 100 mm diameter × 15 mm height |
| Material | Polystyrene, optically clear |
| Lid | Vented, for gas exchange |
| Sterility state | Sterile, single use |
| Stacking | Not designed for stacking (vented lid) |
| Case configuration | 500 dishes per case |
| Intended use | Microbiological culture work |
| SKU | CLI-PETRI-100 |
| Case price | $102.39, about 20 cents a plate |
Standard 100 x 15 mm petri dishes in optically clear polystyrene, supplied sterile in cases of 500. The shallow profile and uniform wall thickness make colony counting and plate photography repeatable between operators.
Sold as empty, sterile dishes — agar and media are not included. That keeps the plate suitable for whichever prepared medium your lab already validates, and avoids the shipment and shelf-life problems that come with pre-poured plates.
100 × 15 mm specifications at a glance
The table below carries the numbers a method writer or a purchasing officer usually needs before choosing a plate: the diameter, the depth, the surface available for growth, and how much medium it takes to reach a working depth. The growth area and the agar volume are the arithmetic of the format rather than a supplier claim, which is why they are useful when a procedure specifies a pour volume in millilitres instead of a depth in millimetres.
| Parameter | Detail |
|---|---|
| Diameter | 100 mm |
| Height | 15 mm |
| Material | Polystyrene, optically clear |
| Sterility state | Supplied sterile, single use |
| Lid | Vented, for gas exchange |
| Growth area | About 69 cm² |
| Agar volume at 3 mm depth | About 21 mL |
| Typical pour volume | 15–20 mL |
| Case configuration | 500 dishes per case |
| Stacking | Not designed for stacking (vented lid) |
| Intended use | Microbiological culture work |
| Item code | CLI-PETRI-100 |
How much agar goes into a 100 × 15 mm dish?
The working rule is depth, not volume: a plate is poured to roughly 3 mm of medium, which is deep enough that colonies have room to develop their full shape and shallow enough that light still passes through for counting on a bright background. For a 100 × 15 mm dish the growth surface is about 69 cm², and 69 cm² at 3 mm works out to about 21 mL. In practice most methods pour somewhere between 15 mL and 20 mL, and the plate still reads correctly as long as the layer is even across the whole surface.
Why the thickness matters more than it sounds. A plate poured too thin dries at the edges during a long incubation, and colonies near the rim stop developing or merge into the drying front, which changes a count without anything being wrong with the sample. A plate poured too thick takes longer to set, holds more condensation under the lid, and puts the colonies further from the surface a counter or a camera is focused on — which matters when two operators read the same plate and are supposed to get the same number.
The figure is also the easiest way to cost a programme. If a method pours 20 mL per plate, a case of 500 dishes takes about ten litres of prepared medium, and that number belongs in the media-preparation plan next to the plate order rather than being discovered on the day.
What the dish does not decide is the medium. Whether the lab pours a general nutrient agar, a selective medium, or a chromogenic one, and what supplements go in, is set by the method being followed and validated; the dish only has to present it at a consistent depth. Plates should be left to set flat on a level surface, and the surface dried to whatever degree the procedure requires before inoculation.
Which plate format do routine colony counts actually expect?
100 × 15 mm is the general-purpose format that most validated methods name for pour plates, spread plates and streak plates: the diameter gives a countable surface without crowding colonies, and the depth leaves room for a poured medium layer. Smaller formats exist for specific methods, so the rule is to match whatever the written procedure specifies rather than substituting. The vented lid allows gas exchange during incubation; keep the dish flat — a vented lid is not designed for stacking, so plates should not be stacked during incubation.
100 mm vs 90 mm vs 60 mm: which size should a lab order?
Three diameters cover almost everything a Canadian laboratory buys. The 60 mm (6 cm) dish is the small format: about 23 cm² of growth area, and a pour of roughly 7 mL at 3 mm. It is used where the plate itself is the sample — contact plates and small screening plates — and where the medium is the expensive part of the test, because a small plate spends a fraction of what a full-size plate spends per test. The 90 mm dish is the classic clinical and water laboratory format: about 57 cm² and roughly 17 mL, and the size most established methods were written around. The 100 × 15 mm dish is the larger general-purpose format: about 69 cm² and roughly 21 mL, with the extra surface and depth that routine plate counts and multi-sector streak plates benefit from.
The decision sequence that saves the most rework is: read the written method first, and order the diameter it names — a procedure validated on one size is not automatically equivalent on another. Then check the physical fit. If the laboratory counts on an automated instrument, the dish has to sit in that instrument's carrier, and the counter's calibration belongs to one diameter. If the incubator is full, stack height and shelf footprint decide how many plates a run can hold, and the difference between a 90 mm and a 100 mm footprint multiplied across a few hundred plates is real shelf space.
After that, compare the arithmetic of the test rather than the price of the case. A larger plate carries more medium per test; a smaller plate carries less. Where a sample series needs a countable plate at each dilution, the size that lands the count inside the readable range with the fewest plates per sample is the cheaper one to run, whatever the case costs.
| Format | Growth area | Agar at 3 mm depth | Typical use |
|---|---|---|---|
| 60 mm (6 cm) | About 23 cm² | About 7 mL | Contact and screening plates, teaching, methods where the medium is the main cost |
| 90 mm | About 57 cm² | About 17 mL | Established clinical and water methods written around this size |
| 100 × 15 mm | About 69 cm² | About 21 mL | Routine plate counts, multi-sector streak plates, environmental sampling |
One practical note on mixing formats: if a laboratory keeps two diameters, the incubator, the counter and the media plan all have to handle both, and the labels have to say which is which. Standardising on one diameter for the routine work and buying the other only for the specific method it belongs to is usually the cheaper arrangement.
Vented or non-vented: which lid for which work?
A vented lid has small gaps or raised ribs that let air move between the inside of the dish and the incubator, and that single feature decides most of the choice. Gas exchange keeps the atmosphere in the dish close to the atmosphere in the incubator, and it lets condensation escape instead of pooling on the lid and dripping onto the agar when the plate is moved or inverted.
A non-vented lid closes that exchange down. That is what a slow-growing organism or a long incubation wants, because the plate does not dry out at the same rate, and it is what a sealed or wrapped plate needs when the point is to hold a modified atmosphere. It is also the safer choice whenever a plate leaves the building, because a plate in transit is a plate that can leak.
| Situation | Lid | Why |
|---|---|---|
| Short incubation with daily reading | Vented | Gas exchange, less condensation on the lid, plates can be read without wiping |
| Long incubation or slow-growing organisms | Non-vented, or vented and sealed once inoculated | Slows drying, holds humidity across the run |
| Transport or send-out to another site | Non-vented, bagged | Containment in transit, no leaking through vents |
| Shared incubator used by several people | Vented, as the procedure states | Consistent atmosphere for every plate in the run, and the usual arrangement where plates are opened during reading |
| Work that needs a modified atmosphere | Non-vented, sealed with a gas-generating system | The seal is what keeps the atmosphere in place |
The dish on this listing has a vented lid, which is the arrangement routine plate counts and streak plates are normally run with. Where a method calls for a sealed plate, the seal is applied after inoculation and the vent then stops mattering — the plate behaves as a closed vessel from that point on.
How do you keep plates sterile in storage, and how are they disposed of?
Keep the sleeve closed until the plate is needed, work from one sleeve at a time, and never return an opened plate to the sleeve — a lid that has been off on a bench is no longer sterile, and the medium will show it. These dishes are polystyrene and single use: they deform in an autoclave, so glass is the reusable option if the workflow is heat-based. After reading, plates go into the biohazard waste stream rather than general refuse, sealed in the bag the waste carrier accepts.
Plate and consumable volumes for a sampling programme can be modelled on the sampling programme planner; culture and media-preparation templates print from the compliance log centre, which also carries the sterilization log generator for the reusable glassware side. Laboratory and multi-site volumes are quoted at our clinic ordering desk, and method or documentation questions can be raised with the compliance desk.
CliniEco Medical brings this dish into Canada under MDEL #35334, and lot documentation is available with the case.
How should plates be labelled, stored and incubated?
Label the base, not the lid. Lids get swapped between plates on a busy bench, and a plate whose identity lives on the lid is a plate that can be counted against the wrong sample. A workable minimum is the date poured, the medium, the sample identifier and dilution, and the initials of the person who poured or plated it — written on the base with a marker that survives the incubator and, if the plate is stored, the fridge.
Prepared plates are stored inverted at 2–8 °C, in their sleeve or a sealed bag, and brought back to room temperature before use so that condensation does not form on the agar when the lid comes off. Inverting them in storage keeps any condensation that does form on the lid rather than on the medium. First in, first out: the oldest sleeve is used first, and the date on the base is what decides which one that is.
Incubation is inverted as well, for the same reason — a plate that sits lid-up collects water on the inside of the lid, and when it is moved to a counter that water lands on the agar and smears colonies together. The temperature is whatever the method names; clinical work is commonly run near body temperature, environmental and food work at lower temperatures over a longer period, and the number in the procedure is the one that applies rather than a general figure.
Reading and recording: count from the underside against a suitable background, note the dilution, and record anything that made the plate hard to read — a drying edge, a spreading colony, an obvious contaminant. Plates with contamination are recorded rather than quietly discarded, because a run of contaminated plates is a signal about technique or about the incubator. After reading, the plate is biohazard waste: it goes into the waste stream the receiving carrier accepts, sealed, not into general refuse.
None of the above replaces local procedure. Handling, storage limits and record retention are set by the laboratory's own standard operating procedure and by provincial requirements, and those take precedence over any general guidance on a product page.
What documentation should come with a case?
Traceability starts with the lot number. The case and its inner sleeves carry a lot reference from the manufacturer, and that reference is what links a plate on a bench back to the batch it came from — which is the question that gets asked when a count looks wrong, or when an auditor wants to know what was used on a given date. Record the lot number when the case is opened and keep it with the plate records rather than leaving it on the carton.
For the batch documentation itself — the sterilization information and the lot record issued for that batch — ask us and we will pass on what the manufacturer provides for the lot you received. That is a request per batch, not a certificate that ships inside every case, so if your quality system requires a document on file before use, raise it when the order is placed and keep the reply with the batch record.
On arrival, three checks are worth doing before the case goes on the shelf: the number of cases and sleeves against the packing document, the condition of the cartons and of the sleeve seals, and whether the lot reference on the cartons matches the lot reference on the sleeves inside. A damaged sleeve is a plate that is no longer sterile; it should be set aside and reported rather than pushed to the back of the shelf.
Where a laboratory is accredited or audited, the plate supplier is part of the record: the item code, the lot, and the date received are the three fields an auditor is most likely to ask for, and all three are on the carton when it arrives.
Who it is for
- Food and beverage plant microbiology labs running routine plate counts
- Environmental and water testing laboratories
- School, college and university teaching labs
- Compounding pharmacies and clinics performing sterility checks
How many cases should a lab order at a time?
Work from weekly usage, not from the case size. One case holds 500 dishes, so a laboratory that plates 100 dishes a week is holding about five weeks of supply in a single case; at 250 a week the same case lasts a little over one week. That arithmetic is the whole calculation, and it is worth doing once because the answer decides both how often the order is placed and how much shelf space the plates occupy.
Two things pull in opposite directions. Ordering too little means a run is delayed for want of a plate, which is the failure mode that costs the most because the sample is already in hand. Ordering too much means sleeves sit at the back of a shelf for months, in a stack that gets moved and squeezed every time something is taken out — and polystyrene sleeves that have been handled repeatedly are not the ones to trust for a critical count. A stock level of roughly four to six weeks of use, reviewed against actual usage rather than the original estimate, is the usual compromise.
Storage is part of the same decision: plates are kept in their original sleeves, in a dry place, off the floor, and rotated so the oldest sleeve is used first. Where the laboratory runs more than one method, the case count per method should be sized separately, because the methods rarely consume plates at the same rate.
For laboratories and multi-site groups placing standing orders, the case size is also the unit that makes the paperwork simple: 500 per case means quantities are whole cases rather than part sleeves, and a purchase order can be written in the same unit the shelf is stocked in.
Ordering and compliance notes
Pair with inoculating loops, spreaders and colony counters for a complete bench set-up. If your workflow uses pre-poured or pre-prepared plates with agar, that is a separate product family with its own supply and regulatory treatment.
Related reading
- Food plant microbiology lab: starter supply checklist
- USP 71 sterility testing explained
- Microbiology lab: sampling, verification and record-keeping
- Sterile petri dishes: handling, labelling and incubation basics
- Petri dish sizes for Canadian labs: bulk ordering and case counts
- Vented vs non-vented petri dishes for clinic laboratories
Buying for a clinic, lab or care home? Order the case size online, or request a B2B quote for volume pricing, standing orders and purchase-order terms at CliniEco bulk quote.
Related articles
Common questions
What sizes does it come in, and how do I choose?
100 x 15 mm petri dishes in optically clear polystyrene, supplied sterile in cases of 500.
What size is a standard petri dish?
100 x 15 mm is the standard general-purpose size for plate counts and streak plates. Smaller 60 mm and 90 mm formats exist for specific methods; match whatever your validated procedure names.
Are these dishes sterile?
Yes, the case is supplied sterile and single use. Keep the sleeve closed until the plate is needed and discard after use.
Can I autoclave polystyrene dishes?
No. Polystyrene is a single-use plastic and will deform in an autoclave. Sterile dishes are used once; glass dishes are the reusable alternative for heat-based workflows.
Do you sell pre-poured agar plates?
Not currently. Our listing is for empty sterile dishes, which lets each lab use the medium it has already validated.