CliniEco 24-hour biological indicator, 50 PACK — six indicators shown; 1 pack = 50 sterile indicators
+6more

CliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50 Tests

SKU CLI-STER-BI-50 · CliniEco Medical
$79.00
In stock · ships from Toronto, ON
Self-contained biological indicatortype
24 hoursreadout time
50 testspack quantity
Steam autoclave sterilization monitoringuse
Pack sizeSingle configuration Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping across Canada — included

Specifications

TypeSelf-contained biological indicator
Readout time24 hours
Pack quantity50 tests
UseSteam autoclave sterilization monitoring
Result indicationColour change
SKUCLI-STER-BI-50
BrandCliniEco Medical

Pricing

OrderUnit price
1 unit$79.00 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 27 sections · specs, use, compliance

CliniEco Medical supplies 24-hour biological indicators from Toronto, Ontario, and ships across Canada.

Each box contains 50 self-contained spore strips for steam sterilization, read out in 24 hours.

Each lot is manufactured to ISO 11138-3 and ISO 11138-1, and carries Health Canada MDEL #35334.

Lot-level CoA and D-value reports are available on request, and orders ship from stock in Toronto.

Proof for this lot — D-value report (steam, 121 °C) · lot-level CoA on request · Health Canada MDEL #35334. How we verify sterilization monitoring →

How many test days does a 50-pack of 24-hour indicators cover?

Fifty vials is fifty test days for one sterilizer, because the daily routine takes one indicator per unit on every day the unit is used. A room that runs its autoclave on 22 to 25 days a month therefore works through a box in roughly two months on a single unit, and in roughly one month once a second sterilizer is added and takes its own vial on each of those days. That arithmetic is what the three box sizes are for: the 25-vial box suits a light single-unit schedule, fifty sits between the two, and the 100-vial box is the two-unit, most-days-of-the-month format.

Which packing suits a two-sterilizer room better — two 50-packs or one 100-pack?

Both put 100 vials on the shelf, so the decision is about how the stock is opened rather than how much arrives. Two 50-vial boxes let one box stay sealed while the working box runs dry, which keeps an untouched lot intact until the first box is finished; one 100-vial box means both sterilizers draw from the same opened container from day one. If the second unit is new, or runs on an irregular schedule, the two-box route mirrors the way its use days actually accumulate. Read the lot code on the box against the certificate that travels with it either way, because the record is per lot and not per box size.

What does the 24-hour readout change about releasing a load?

It moves the decision into the next working day instead of the day after. The vial is incubated at 56–60 °C (58 ± 2 °C) in a dry-block incubator and read at 24 hours: purple means no spore growth and the load releases, yellow means the spores survived and everything in that load goes back for re-sterilization and a repeat test. One unexposed indicator from the same lot runs as a positive control on each day of testing — if the control does not turn yellow, the run itself is not valid and the day's result cannot be read as a pass.

24-hour self-contained biological indicators: what the 50-vial box carries as listed
Item As listed on this page
Indicators per box 50 self-contained vials
Challenge organism Geobacillus stearothermophilus ATCC 7953
Spore load ≥1.0 × 10⁶ CFU per vial, typical 1.0–1.2 × 10⁶ as stated on each lot CoA
Readout 24-hour visual colour change, no reader or UV lamp
Incubation 56–60 °C (58 ± 2 °C) dry-block incubator
Cycles covered 121 °C gravity-displacement and 132–135 °C vacuum-assisted steam
Format Self-contained vial with growth medium, no transfer step
Testing frequency Every day of use per Ontario dental guidance; at least weekly as the CDC / AAMI ST79 floor
Distribution CliniEco MDEL #35334

CliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack

A test day only counts if it is written down: the printable spore-test log sheet carries the date, sterilizer, lot and result, and the same page holds the sterilization log generator for the cycle record behind it. Documentation questions about what to keep, and for how long, go to the compliance documentation desk.

Cultures and consumables reach Canadian clinics from CliniEco Medical under MDEL #35334.

CliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack

Daily biological monitoring for Canadian dental clinics — 24-hour results, with the per-test figure taken from the box amount on this page

In-office monitoring — incubate and read on site; no need to send vials to an outside lab.

G. stearothermophilus ATCC 7953 · ISO 11138-3

Daily spore testing — 24-hour results

50 self-contained biological indicators in the box, priced on this page — the per-test figure is that amount divided by fifty. Each vial contains Geobacillus stearothermophilus ATCC 7953 spores (≥1.0 × 106 CFU per vial, typical 1.0–1.2 × 106, as stated on each lot CoA), the standard challenge organism for steam sterilization, in a self-contained vial with growth medium for a rapid visual readout in 24 hours instead of 48. In Ontario, the RCDSO requires a biological indicator for each sterilizer on every day that it is used — daily monitoring, not weekly. The weekly baseline is the CDC / AAMI ST79 standard in most US states. Each monitoring day uses two indicators — one test plus one unexposed positive control — so a 50-pack gives about 25 monitoring days.

🛡️ Where Your BIs Come From — Traceability You Can Verify

🏭 Factory Documentation on Request

Every lot ships with full manufacturer documentation available on request — the same supply chain used by established sterilization brands.

🧪 Standard Challenge Organism

Geobacillus stearothermophilus ATCC 7953 — the internationally accepted steam sterilization challenge organism, ≥1.0 × 106 CFU per vial (typical 1.0–1.2 × 106), verified per ISO 11138-1.

📋 Batch Traceability

Every pack carries lot-level traceability. Batch D-value and spore-count documentation available — ask us for the certificate of analysis for your lot.

🇨🇦 Canadian Import & Distribution

Imported and distributed by CliniEco Medical (MDEL #35334) — with English/French labeling and Toronto-based support.

📦 Importer & Regulatory Information

Imported and distributed by: CliniEco Medical (Ecology Source New Energy Technology Co., Ltd.)
255 Duncan Mill Road, Suite 512, Toronto, ON M3B 3H9, Canada
Storage: 15–30°C, away from direct sunlight and moisture. Shelf life: 24 months from manufacture; EXP printed on every vial. For professional use only. Do not use if damaged or expired.
Conforms to EN ISO 11138-3 (moist heat) and EN ISO 11138-1 — third-party test report XDX522601161208BST (BST Testing, EN ISO 11138-1:2017 and -3:2017) available on request. For steam sterilization only — not for dry heat, chemical vapour, ethylene oxide (EO) or other low-temperature processes.

Have a question about your own facility? Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. Ask your compliance question.

✅ ISO 11138-3 Compliant ✅ ATCC 7953 Challenge Organism ✅ Batch Traceability

When the 50-Pack Fits Better Than the 25 or the 100

A test day takes two indicators from the same lot — the vial that runs through the cycle and the unexposed control that must turn yellow for the run to be valid. Work out the year as test days multiplied by two, then pick the box that lands closest to it without leaving you short mid-quarter.

Test days a year Indicators a year 50-packs a year Cost in 50-packs, $109.99 each The same year bought as 25-packs, $69.99 each
25 50 1 $109.99 2 boxes — $139.98
30 60 2 $219.98 3 boxes — $209.97
35 70 2 $219.98 3 boxes — $209.97
40 80 2 $219.98 4 boxes — $279.96
49 98 2 $219.98 4 boxes — $279.96

This box sits between the entry pack and the yearly box. Choose it when your test calendar is real but not daily, or when you want the ordering rhythm to be quarterly instead of monthly.

Two situations this box is built for

  • Two sterilizers on alternating days. Each unit is tested on the days it actually runs, so the test days roughly double and the box empties at twice the pace. Buying two 25-packs a month for that rhythm costs more than one 50-pack a quarter.
  • A two-month to three-month restock cycle. A practice that runs two or three days a week gets about two to three months of cover from this box, which means four deliveries a year and a single lot number per quarter — easier to file and easier to trace back if a lot is ever questioned.
  • One sterilizer plus a backup unit. If the backup is run only on weeks when the main unit is serviced, the extra test days land in bursts; the 50-pack absorbs the burst without a special order.

When the 50-pack is the wrong box

  • More than 49 test days a year: step to the 100-pack, because a hundred vials spread the box amount further and the per-test gap compounds across a year.
  • Under 25 test days a year, or a new routine you have not yet proven: the 25-pack at $69.99 covers twelve test days and keeps the exposure small.
  • Storage that runs warm or damp: indicator vials belong in a dry place at room temperature, and a box that sits for a year in a utility room is a risk you do not need to take for a few dollars a box.

What one box covers, week by week

Fifty indicators is 25 test days. At five test days a week that is five weeks; at three days a week, about eight weeks; at two days a week, about twelve. Write your own test days a week into that line before ordering — if the answer is over fourteen weeks, the box will outlast your patience before it outlasts the shelf, and the 25-pack is the better rhythm.

The same year, priced against the neighbours

Test days a year Indicators Bought as 50-packs Bought as 25-packs Bought as 100-packs
25 50 1 box — $109.99 2 boxes — $139.98 1 box — $189.00
40 80 2 boxes — $219.98 4 boxes — $279.96 1 box — $189.00

That last row is the honest one: at 80 indicators a year a single 100-pack is cheaper than two 50-packs, but it leaves twenty vials on the shelf. If your test days are steady and the lot date allows it, the larger box wins on price; if the routine is still settling, pay the small premium and keep the shelf light.

How to Read Your 24-Hour Result

Negative — pass The medium stays purple after 24 hours at 56–60 °C (58 ± 2 °C): no spore growth. Release the load.
Positive — fail The medium turns yellow: spores survived the cycle. Re-sterilize everything in that load and re-test before releasing instruments.
Incubation 56–60 °C (58 ± 2 °C) dry-block incubator; read at 24 hours (this indicator is rated for a 24-hour readout, not 48 hours).
Positive control Run one unexposed indicator from the same lot as a control on each day you test; it must turn yellow. If the control does not grow, the test run is not valid.
Reading is visual No reader or UV lamp is needed.
Source Manufacturer's instructions for use supplied with each lot.

Product Specifications

Brand CliniEco Medical
Organism Geobacillus stearothermophilus ATCC 7953 — ≥1.0 × 106 CFU per vial (typical 1.0–1.2 × 106)
Readout 24-hour rapid visual readout (color change)
Cycles 121°C gravity & 132–135°C vacuum-assisted steam sterilization
Format Self-contained vial with growth medium — no transfer steps
Pack Size 50 indicators per pack; monitoring log template included
Frequency Daily per sterilizer in Ontario (RCDSO); at least weekly in most US states (CDC / AAMI ST79)
D-value / Z-value Reported for every lot on the CoA — current lot: 2.0 min at 121 °C, Z-value 11.3 °C
Distribution CliniEco MDEL #35334
Certificate of analysis for the 24-hour steam biological indicator (lot sample)

Sample CoA from a production lot — the certificate issued with your shipment carries your lot number and the manufacturer's details.

Features

  • ✓ G. stearothermophilus ATCC 7953 — the accepted steam sterilization challenge organism
  • ✓ 24-hour result — results a day sooner than 48-hour vials
  • ✓ Self-contained (SCBI) — ampoule and medium in one vial
  • ✓ Monitoring record log template included — supports RCDSO daily documentation and CDC / AAMI ST79

Compliance

  • RCDSO (Ontario): a biological indicator for each sterilizer on every day that it is used — daily, per RCDSO IPAC standard 03/24_5542
  • CDC and AAMI ST79: spore test at least weekly per sterilizer (US baseline)
  • Test organism: Geobacillus stearothermophilus ATCC 7953 (steam)
  • Distributed by CliniEco Medical under MDEL #35334
  • Manufactured to EN ISO 11138-3 and EN ISO 11138-1 — documentation available on request

Hardware is sold separately — buy only what you need

We do not bundle hardware into a plan. Prices:

  • 24-Hour Dry-Block Incubator — $379
  • Rapid Reader, 4-well fluorescence — $1,499 (3-hour results)

Both include free printable record sheets. No lock-in — our BIs work in any standard 56–60 °C (58 ± 2 °C) incubator.

Start BI Plan — Reserve Your Free Device →

CliniEco Service Promise

  • Free shipping on this 50-pack — anywhere in Canada
  • Ships from our next production lot — dispatch date confirmed by email within one business day
  • Canadian-owned company
  • Batch documentation available — CoA, D-value and spore count on request

Technical Documents

Everything below is on file for this product. Download what you need; the two documents we send individually are requested by batch so that what you receive matches the box in front of you.

Product Data Sheet (PDS) — full specifications, test organism, D-value, storage and stated limitations. Download PDF →
Third-Party Verification Summary — report number, issuing laboratory, standards applied, result. Download PDF →
D-Value Report — measured D-value at 121 °C. Download PDF →
24-Month Stability Study — real-time stability data behind the stated shelf life. Download PDF →
Certificate of Analysis — issued for every batch we ship. Request by batch number →
Full third-party laboratory report (12 pages) — request

Manufactured by Chengdu QAMED Co., Ltd. (No.80 & 82 Jiangling Road, Xindu District, Chengdu, China; ISO 13485 certificate 280012038605752, valid to 7 March 2029). Imported and distributed in Canada under Health Canada MDEL #35334.

All technical documents →

Clinic & Volume Pricing

Contact us for volume pricing — email alina@clinieco.ca.

  • Volume pricing for clinics, dental practices, LTC homes and distributors
  • Free shipping on this item — anywhere in Canada

Why Buy CliniEco?

  • 24-hour results, with the per-test figure shown on this page — a lower per-test figure than our 25-pack
  • Compliance built in — the monitoring record log template supports RCDSO daily documentation and CDC / AAMI ST79 expectations
  • Complete reprocessing line — pairs with CliniEco pouches, rolls, tape and cleaning solution
  • Full traceability — factory documentation, batch CoA, Canadian import

Related tests in this BI line

Related articles

How does daily monitoring in Canada compare with the weekly baseline in the United States?

The interval is set where the clinic is, not by the indicator. In Ontario the requirement is a biological indicator for each sterilizer on every day that sterilizer is used, which is the RCDSO IPAC standard 03/24_5542 wording; in most US states the floor is the CDC and AAMI ST79 baseline of at least weekly per sterilizer. The same 50-vial box covers a different length of calendar depending on which of those two regimes the room is under, so the frequency is the first question to settle before choosing a pack size.

Item Canada (Ontario) United States
Testing interval A biological indicator for each sterilizer on every day it is used — daily At least weekly per sterilizer — the CDC / AAMI ST79 baseline
Where the rule comes from RCDSO IPAC standard 03/24_5542 CDC guidance and AAMI ST79
Indicators per test day One test vial plus one unexposed control from the same lot One test vial plus a control run on the day the test is done
What 50 vials covers About 25 monitoring days — roughly one month of daily testing for one sterilizer About 25 monitoring days — closer to six months at a weekly interval
Effect on pack size The 50-pack sits between the 25 and the 100 because daily testing burns through stock A 25-pack often covers a quarter or more, so the 50 and 100 packs suit multi-sterilizer rooms
Record kept Date, sterilizer, lot and result on the daily log Same fields; the retention period follows the facility's own policy

Two notes on that table, because a pack-size decision built on the wrong one costs a year of stock. First, Ontario is the province whose rule is quoted here; other provinces set their own monitoring intervals through their dental colleges, and a clinic outside Ontario should read the requirement it is actually inspected against. Second, the weekly interval is a floor and not a ceiling: an office that has had a failed test, a new sterilizer or a repaired unit will test more often for a period, and the box has to absorb that.

What has to be in place before the first test day?

A 50-pack on a shelf is not a monitoring programme. Three things sit around it, and a practice that buys the box without them ends up with a lot of vials and no usable record.

Item What it has to be Why the box alone will not do
Incubation A dry-block incubator held at 56–60 °C (58 ± 2 °C) The vial is read at 24 hours at that temperature; there is no room-temperature route to the result
Positive control One unexposed vial from the same lot on each day of testing If the control does not turn yellow, the run is not valid and the day's result cannot be read as a pass
Log Date, sterilizer, lot code and result, written on the day A test that is not written down cannot be produced at an audit
Lot record The certificate that travels with the lot, filed against the lot code on the box The D-value and spore count are per lot, not per box size
Failure route A written step for a yellow vial: quarantine the load, re-sterilize, re-test The result is only useful if the room already knows what it does with a fail

How should the vials be stored between test days?

Store the box between 15 and 30 °C at 30–65 % relative humidity, away from sterilants, direct sunlight and UV, and do not crush the packaging — a cracked vial is not a test. Shelf life is 24 months from the date of manufacture, and the expiry is printed on every vial rather than only on the carton, which is what lets a practice keep a part-used box on the shelf and still read the date off each vial it picks up.

The failure mode to design against is not heat but the utility room. A box that sits for a year next to a still-air autoclave, a chemical store or a window will be out of its stated storage band for most of that time, and the vials will look exactly the same as good ones. Keep the working box in the treatment area where the incubator is, and keep the spare box dry.

Common questions

How often should we run a spore test?

It depends on the jurisdiction. In Ontario, the RCDSO requires a biological indicator for each sterilizer on every day that it is used — daily monitoring. In most US states, the CDC and AAMI ST79 baseline is at least weekly. One 50-pack covers about one month of daily testing for one sterilizer.

How do I read the result?

After the cycle, activate the vial per the included instructions and incubate; read at 24 hours. No color change means no surviving spores (pass); a color change means failure — quarantine the load and re-test the sterilizer.

What organism is used, and why?

Geobacillus stearothermophilus ATCC 7953 — the standard biological challenge for steam because of its high heat resistance. A compact dry-block incubator is available on request.

Can I see the factory documentation?

Yes — we provide the test reports behind the standards listed above and batch certificates of analysis on request. Email alina@clinieco.ca.

Does it work with my autoclave cycle type?

This item is used with standard steam sterilization cycles; confirm the specific cycle against the manufacturer's instructions supplied with each lot.

How should it be stored, and how long does it keep?

Store between 15–30 °C at 30–65% relative humidity, keep away from sterilants, direct sunlight and UV, and do not crush the packaging. Shelf life is 24 months from the date of manufacture.

How often does a Canadian clinic need to run it?

In Ontario, the RCDSO requires a biological indicator for each sterilizer on every day that it is used — daily monitoring, not week.

Which standard does it meet?

Manufactured and tested to EN ISO 11138-1 and EN ISO 11138-3. Manufacturer documentation available on request.

How long does a 24-hour readout biological indicator take to incubate?

This is a self-contained 24-hour test: after the cycle the indicator is activated and incubated, and the readout is available at the time stated in the manufacturer's instructions for use — around 24 hours. Keep the activated indicator in the incubator for the full period before reading it, and read the result against the control.

Is a 24-hour biological indicator acceptable for RCDSO daily monitoring?

The requirement is about how often you test, not how fast the indicator reads. In Ontario the RCDSO expects a biological indicator for each sterilizer on every day the sterilizer is used — daily monitoring, not weekly — placed in a process challenge device and run for each type of cycle used that day. The weekly interval is the CDC / AAMI ST79 baseline in most US states. A 24-hour readout fits a daily schedule; where same-shift release is needed, a rapid-readout indicator is used instead.

How is this different from the 3-hour indicator and the 5-pack trial?

All three are biological indicators with the same pass-or-fail meaning; the difference is the readout time and the pack size. The 3-hour unit is a fluorescence test for same-shift release, this 24-hour unit suits a next-day schedule, and the 5-pack trial is a small pack to evaluate the routine before committing to a working size.

How many indicators does one test need, and how long should records be kept?

One indicator per sterilizer for each day it is used, plus a control. File the result in a log that matches your facility's records-retention policy, and note the sterilizer, the cycle type and the date alongside it.