Free Sterilization Compliance Self-Check (by Province)
Sterilization Compliance Self-Check
Request my free 5-pack of biological indicators →
Start here — the spore testing is free
A self-check tells you what an inspector looks for. The other half of the record is spore testing: clinics in Canada can get a free 5-pack of 24-hour biological indicators — postage covered, no account needed.
Questions on frequency or records? Ask a compliance specialist.
See what a provincial inspector typically looks for in your sterilization records — and where your current routine may fall short.
A 2-minute check. No account, no sign-up, no email required. You get the full result on screen, and you can print it.
Choose your setting
We only show a verified checklist once we have mapped that setting field by field against its own regulator's published requirements. So far we have completed this for dental (Ontario).
You have answered 0 of 14 items
A · Biological monitoring
-
A1 Do you run biological indicator (BI) testing?
Evidence & risk
Evidence: RCDSO IPAC Standard of Practice (v3)
Chemical indicators show a cycle ran; only a BI directly verifies sterilization was achieved.
What to do next
Get your free 5-pack of 24-hour BIs → /pages/bi-sample-request
-
A2 How often do you run a BI test?
Evidence & risk
Evidence: RCDSO IPAC Self Audit Review Form (v2) — a biological indicator plus a control, once daily for each type of cycle.
🔴 Your current cadence is below the Ontario requirement. Following a weekly spore-testing routine is a common finding during an inspection.
What to do next
Print your daily BI record sheet → /pages/compliance-log-center
Ask a compliance specialist → /pages/sterilization-compliance-consultation
-
A3 When you run a BI, do you also run a control?
Evidence & risk
Evidence: The same RCDSO form — "a biological indicator plus a control".
Without a control, a positive result cannot be attributed to the sterilizer rather than the indicator itself.
What to do next
BI product page (with control)
-
A4 If a BI comes back positive, do you know what to do next?
Evidence & risk
Evidence: RCDSO — take the sterilizer out of service, then review the physical and chemical indicator records since the last negative result.
With no protocol, instruments may be released from a failed load — this is the highest-risk gap on this list.
What to do next
Positive-result protocol (on-site, linked)
B · Sterilization load records
-
B1 Do you keep a record for every sterilization load or cycle?
Evidence & risk
Evidence: RCDSO IPAC Self Audit Review Form (v2) — record group 1.
With no record, you cannot show an inspector that the cycle was run or checked.
What to do next
Log sheet generator → /pages/compliance-log-center
-
B2 Does your record contain all nine fields?
date · sterilizer number · load number · load contents · cycle · sterilization time · temperature · pressure · person responsible
Evidence & risk
Evidence: RCDSO IPAC Self Audit Review Form (v2) — mapped field by field.
A missing field counts as an incomplete record during an inspection.
What to do next
Log sheet generator (built on the 9 required fields) → /pages/compliance-log-center
-
B3 Even if your sterilizer prints a chart, do you still record time, temperature and pressure?
Evidence & risk
Evidence: RCDSO — where a sterilizer has a recording device, the physical parameters are checked at the end of the cycle and documented; without one, they are checked during the cycle and documented, and cannot be filled in afterwards from memory.
"The chart covers it" leaves three of the nine fields blank.
What to do next
Log sheet generator → /pages/compliance-log-center
C · Maintenance and malfunction
-
C1 Do you keep a service and maintenance log (date, who did it, what was done)?
Evidence & risk
Evidence: RCDSO IPAC Self Audit Review Form (v2) — record group 2.
Equipment drift can cause sterilization failure without an error showing.
What to do next
Record sheet (covers this record group)
-
C2 Do you keep a malfunction log, with the action taken?
Evidence & risk
Evidence: RCDSO IPAC Self Audit Review Form (v2) — record group 3.
Without it, you cannot trace which instruments came from a suspect cycle.
What to do next
Record sheet (covers this record group)
D · Package labels
-
D1 Does every sterilized package carry the required label information?
Evidence & risk
Evidence: RCDSO IPAC Self Audit Review Form (v2) — record group 4, "package label set".
Without traceable labels you cannot scope a recall to the right loads.
What to do next
Label generator → /pages/compliance-log-center
E · Retention
-
E1 How long do you keep your sterilization records?
Evidence & risk
Evidence: RCDSO IPAC Standard of Practice (v3); the same form states "Logbook kept for 10 years after last entry".
Less than 10 years leaves a gap inside the traceability window.
What to do next
Keep it here (auto-retained, with expiry reminder)
F · Pre-sterilization
-
F1 Are instruments cleaned and decontaminated before sterilization?
🟡 Not yet verified word-for-word against RCDSOEvidence & risk
Evidence: 🟡 General IPAC practice. We have not verified this specific item word-for-word against the RCDSO text, so we label it as general practice rather than quoting the regulator.
Organic residue can cause sterilization to fail.
What to do next
Cleaning consumables / ultrasonic cleaner
G · People and process
-
G1 Is the person responsible for sterilization named on the record?
Evidence & risk
Evidence: RCDSO IPAC Self Audit Review Form (v2) — one of the nine load-record fields is the name of the person responsible for sterilization.
Without a name, responsibility cannot be traced.
What to do next
The log sheet carries this field → /pages/compliance-log-center
-
G2 Does everyone follow the same written procedure?
Evidence & risk
Evidence: RCDSO 5540 — Dental Office Policy and Procedure Manual Template (v3).
Practice varies with whoever is on shift, so results are not reproducible.
What to do next
Ask a compliance specialist → /pages/sterilization-compliance-consultation
Attach a photo of your current record
Take a photo on your phone, or drop a file on your computer.
Your photo is not uploaded. Any text recognition happens inside your browser, and the image stays on your device.
Your self-check result — Dental (Ontario)
You answered 0 / 14 items
- 🔴 0 items need action (needs action)
- ⚠️ 0 items need verification (needs verification)
- ✅ 0 items already in place (already in place)
Based on: RCDSO IPAC Standard of Practice (v3) · RCDSO IPAC Self Audit Review Form (v2) · last checked 2026-10-04
This is a self-check list. It is not a compliance determination and does not replace an inspection by your regulator.
Want to keep this result and be reminded before the items above are due?
Create a free accountFrequently Asked Questions
How often must a biological indicator be run in Ontario?
In Ontario dental practice, biological monitoring is run for each sterilizer on each day it is used, and the record is kept. The frequency is tied to the sterilizer and the day of use, not to a weekly calendar. Where a facility runs more than one cycle type (for example wrapped instruments and hollow loads), each type of cycle is represented in the monitoring record.
Which autoclave type is required for pouched instruments and hollow loads?
Pouched instruments and hollow or lumened loads require air removal that gravity displacement does not reliably provide, which is why a pre-vacuum (Type B) cycle is specified for those loads. A gravity (Type N) cycle is intended for solid, unwrapped items. Using a pouched hollow load in a gravity cycle is a load-type mismatch, independent of whether the sterilizer passed its last spore test.
Which failure mode does a Bowie-Dick test pack detect?
The Bowie-Dick test detects air removal failure — residual air or a steam quality problem that prevents uniform steam penetration in pre-vacuum cycles. It is run on an empty chamber at the start of the day and is not a substitute for spore testing: it answers "did the air come out", not "did the load get sterile".
What does a spore test actually prove?
A passing spore test shows that the cycle conditions delivered enough lethality to kill a defined population of resistant spores in that specific run. It is evidence about that cycle, that load and that day. It does not certify the sterilizer for all future loads, which is why the record matters as much as the result.
How long should sterilization records be kept?
Sterilization monitoring records are retained as part of the facility's infection prevention and control documentation. Because the record is the evidence a regulator or auditor reviews, the practical rule is to keep the lot number, cycle type, result and operator together with each entry — a result without its lot reference cannot be reconciled later.
Does a self-check replace a compliance audit?
No. The self-check maps your current records against the categories a reviewer looks for (biological monitoring, load records, maintenance, packaging labels, retention, pre-sterilization, people and process). It is a gap-finder that shows where documentation is missing; the underlying log and maintenance records remain the evidence.
Related products
- 24-Hour Biological Indicators — 25-Pack — $69.99
- 24-Hour Biological Indicators — 50-Pack — $109.99
- 24-Hour Biological Indicators — 100-Pack — $189.00
Health Canada MDEL #35334