Sterilization compliance kit A for pre-vacuum Class B - 24-hour BI 50-pack, 6 BD packs

Sterilization Compliance Kit — A — For Pre-Vacuum (Class B) Sterilizers

SKU CLI-STER-KIT-PREVAC · CliniEco Medical
$178.00

Ships to Canada only

In stock · ships from Toronto, ON
CLI-STER-KIT-PREVACsku
Sterilization Monitoringcategory
CliniEco Medicalbrand
In stockavailability
Pack sizeSingle configuration Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping across Canada — included

Specifications

SKUCLI-STER-KIT-PREVAC
BrandCliniEco Medical
CategorySterilization Monitoring
AvailabilityIn stock
Ships fromToronto, ON

Pricing

OrderUnit price
1 unit$178.00 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 14 sections · specs, use, compliance

A — For pre-vacuum (Class B) sterilizers

Everything one sterilizer needs to keep its monitoring in order for a month — with 10% spare, so a busy week never leaves you short.

Kit A is sized for one Class B (pre-vacuum) sterilizer and about a month of monitoring — with the 10% spare already built in. The daily spore test is the 24-hour self-contained 50-pack; the rest of the box is what a vacuum cycle needs around it: Bowie-Dick packs, a Class 5 integrator, pouches and indicator tape.

Sterilization Compliance Kit — A — For Pre-Vacuum (Class B) Sterilizers

Which parts of the kit are used on every sterilization day, and which only occasionally?

Three things are daily: one biological indicator, its control, and — on a pre-vacuum sterilizer — a Bowie-Dick test on the first cycle of the day. The Class 5 integrator travels with the work, inside every tray and large pack, so it is consumed by load shape rather than by calendar. Pouches and indicator tape run out at their own pace: the kit holds 800 pouches and a three-roll tape set, counted on a 3–4 chair practice using 400–750 pouches a month, so an empty drawer is not the reason a tray waits.

Does the kit replace the daily record a dental practice has to keep?

No — it supplies the articles the record describes. The record itself is your practice's daily sterilization log, and the obligation to complete it stays with the practice whatever it buys. What we can take out is the friction: the printable daily record on our compliance log centre is free, needs no account, and has fields for the date, the cycle, the sterilizer, the vial lot number and the result. Copy the lot number off the box and the entry writes itself. Where your provincial requirement reads differently from the numbers below, tell us — we would rather correct the kit than have you rely on the wrong count.

How many biological indicators does one Class B sterilizer need in a month, and what does the kit cost per sterilization day?

Fifty, on the pattern of a test plus a control each day the sterilizer runs: two vials a day, so a 50-vial box covers 25 sterilization days — a month with spare, not a second month. The kit lists at $249.00, which is about $9.96 per sterilization day across those 25 days, and that figure already includes the Bowie-Dick packs, the integrator, the pouches and the tape. Kit B, for gravity and non-vacuum sterilizers, lists at $189.00 and leaves out the Bowie-Dick packs, because that test measures air removal and only means something on a pre-vacuum machine.

Kit A contents — pack size, quantity in the box and how long each part covers (pre-vacuum / Class B)
Item in the kit Pack size Quantity in the box How long it covers
Biological indicator, 24-hour readout 50-pack 1 25 sterilization days at test plus control
Bowie-Dick test pack, ISO 11140-5 Type 2 6-pack 4 first cycle of each day, 24 test days
Steam chemical integrator, Class 5 100-pack 1 inside every tray and large pack
Sterilization pouch, Class 4 dual indicator 200 per box 4 800 pouches, sized on 400–750 a month
Autoclave indicator tape 3-roll set 1 sealing and labelling the packs
Kit A, complete — the five lines above $249.00, about one month for one sterilizer

What you reorder, and what you buy once. The kit is the monthly line. The constant-heat pouch sealer sits outside it because it lasts, and the clinic supply planner sits outside it because sizing a second sterilizer is arithmetic, not a purchase. A question about your own setup goes to the compliance desk, which answers in writing with the standard cited. CliniEco Medical imports this kit under MDEL #35334.

Why buy this kit from us

Sterilization compliance for clinics is all we do. So the kit comes with the parts most suppliers leave out:

  • Quantities we can show you the working for — built on the RCDSO's daily testing rule, with spare so a busy week never leaves you short. No guessing at how much you actually use.
  • The record sheet your province asks for — ready to print, free, no account, nothing to buy.
  • A named person who can look up your lot number — email alina@clinieco.ca. Not a ticket queue.
  • Any compliance question, any time — ask us; even if you never buy anything from us, we're glad to talk it through.

What it does not do: it won't tell you whether a cycle passed. That depends on how the sterilizer is loaded and run — that part stays with your team. We supply the monitoring and the guidance around it, not a guarantee of outcomes.

Questions clinics ask before buying

Do I need an incubator?

Yes. These indicators have to be incubated at 58 ± 2 °C before you can read them. A self-contained indicator does not need a reader, but it does need an incubator. If your clinic doesn't have one, we stock one — or email us and we'll help you sort it out rather than send you something you can't use.

How do I know this is the right kit for my sterilizer?

Kit A is for pre-vacuum (Class B) sterilizers — the ones with a vacuum pump that need a daily Bowie-Dick test. Kit B is for gravity / non-vacuum sterilizers, which don't. If you're not sure which yours is, Kit B explains the difference, or email us and we'll tell you.

How long does one kit last?

About a month for a clinic running one sterilizer on a normal schedule. The 50 biological indicators are sized on the RCDSO requirement of a test plus a control each day the sterilizer runs, with spare for the busier weeks.

Why does Kit A include Bowie-Dick tests and Kit B doesn't?

Bowie-Dick is a test of air removal in the chamber. It is only meaningful on pre-vacuum (Class B) sterilizers, so it isn't part of Kit B.

Why is there a Class 5 integrator in both kits?

It goes inside trays and large packs where the pouch indicator can't reach. That applies to both sterilizer types, so both kits include it.

Can I buy the items separately?

Yes — every item in the kit is sold on its own. The kit is for clinics that would rather not work out the quantities, not a way to lock you into a bundle.

What if I run more than one sterilizer, or more than 2 chairs?

Email us before ordering and we'll size it for your volume. The kit is built for a 1–2 chair clinic running one autoclave — it is not meant for 6+ chairs.

Where these numbers come from

  • Biological indicator every day the sterilizer runs, plus a control test — RCDSO Standard 5542, p. 8 (and 5539, p. 23). That is the basis for 50 indicators a month, not 25.
  • Bowie-Dick: pre-vacuum / Class B only, first cycle of each day — RCDSO 5542, p. 7; Public Health Ontario 7.18. A gravity sterilizer does not require it, which is why it is in Kit A only.
  • Pouch count is based on a 3–4 chair practice running 400–750 pouches a month; we round up so you don't run short.

Verified 2026-10-08. If your provincial requirements differ, tell us — we'd rather correct the kit than have you rely on the wrong number.

What's in the kit

  • Biological Indicator — 24-Hour Readout, 50-Pack × 1
  • Bowie-Dick Test Pack — ISO 11140-5 Type 2, 6-pack × 4
  • Steam Chemical Integrator — Class 5, 100-Pack × 1 (for your trays and large packs)
  • Sterilization Pouch — Class 4 Dual Indicator, 200-pack box × 4
  • Autoclave Tape — Sterilization Indicator Tape, 3-Roll Set × 1

Designed for: 1–2 chairs · one Class B (pre-vacuum) sterilizer · no dedicated infection-control staff

Not for: 6+ chairs (larger volume — ask us) · sterilizers other than steam

Covers — products, guidance, records, a specialist who can see your lot number

Does not cover — whether a cycle passes. That depends on how the sterilizer is operated and loaded — that part stays with your team.

Running a gravity / non-vacuum sterilizer? That is Kit B.

Related articles

Common questions

What sizes or formats does Sterilization Compliance Kit come in?

The 50 biological indicators are sized on the RCDSO requirement of a test plus a control each day the sterilizer runs, with spare for.