A clinic ordering exam gloves is really choosing three things at once: the wall thickness, the case build and the paperwork behind the box. Protégé sits at 4.0 mil in a case of ten dispenser boxes, and the range around it runs from a 3.2 mil examination film to a 6 mil glove that is bought for cleaning rounds rather than patient contact. Putting the cases side by side on those three axes is more useful than comparing a single headline number, because the number that decides a repeat order is usually the packing, not the film.
The reference case here is the Protégé nitrile exam gloves, 4.0 mil, 1,000 gloves per case, which is the medical-grade, chemotherapy-tested, sky-blue glove in the range, sold in a single size per case from S to XL.
Which Protégé nitrile exam glove format fits which room of a clinic?
The format follows the task, and clinics tend to run three tasks. Short examination contact, the blood pressure and the throat check, needs feel more than wall, which is where a 3.2 or 3.5 mil film earns its place. Procedural work with an instrument in hand, a matrix band, a bur, a suture pack, is where 4.0 mil is specified, and the Protégé case is the one built for it. Longer procedures that keep the glove on for a while sit one step up at 4.5 mil in the Robust nitrile exam gloves case, which is fully textured and packed the same way. Cleaning and disinfection rounds are a different purchase again, because the glove is worn for the task rather than for a patient, and that is the 6 mil case.
The distinction matters because a clinic that buys one case for everything ends up over-specifying the examination room and under-specifying the utility closet. Two or three formats on the shelf, each with its own reorder point, costs less attention than one format that is wrong half the time.
What does the mil number on an exam glove actually mean?
A mil is one thousandth of an inch, so 1 mil is 0.0254 mm. The 4.0 mil Protégé film is therefore about 0.10 mm, the 3.5 mil case is 0.089 mm as stated on its own listing, and the 6 mil heavy-duty case is 0.15 mm. Thicker film buys resistance to a snag and to a cytotoxic, and it costs feel: palpation through four thousandths of an inch is duller than through three.
Wall thickness is only one of the properties the buyer is relying on. ASTM D6319, the specification for nitrile examination gloves for medical application, current as D6319-19(2023), covers watertightness against the D5151 test, dimensions, tensile strength before and after accelerated aging, and powder residue. A case can be thick and still fail watertightness, which is why the test report matters more than the mil figure.
How do the five glove cases in this range compare?
| Case | Wall | Grade stated on the listing | Case build | Size range | Where it fits |
|---|---|---|---|---|---|
| Transform 100 | 3.2 mil | Medical grade, chemotherapy tested | 10 boxes of 100, about 4.5 kg | S to XL, one size per case | Short examination contact, high glove turnover |
| CliniEco standard | 3.5 mil (0.089 mm) | Examination glove, beaded cuff, micro-textured fingertip | 10 boxes of 100 | S to XL, one size per case | General examination work on a tighter budget |
| Protégé | 4.0 mil | Medical grade, chemotherapy tested, micro-textured | 10 boxes of 100, about 5.3 kg | S to XL, one size per case | Procedural work with an instrument in hand |
| Robust | 4.5 mil | Medical grade, fully textured | 10 boxes of 100 | S to XL, one size per case | Longer procedures where grip matters |
| CliniEco heavy duty | 6 mil (0.15 mm) | Heavy-duty nitrile, black | 10 boxes of 100, or a single 100 box | One size per case | Disinfection rounds, waste handling, cleaning shifts |
The packing is the constant: every case in the range is a thousand gloves unless the single box is bought, and every case is one size. That single-size rule is the one that catches a first order, because a clinic that wears M and L needs two cases, and no carton in this range splits sizes.
How does buying the same glove differ between Canada and the United States?
The product can be identical and the purchase is not. Health Canada's notice on medical gloves states that "medical gloves are classified as Class II devices" whether they are latex, vinyl, synthetic polymer or nitrile, and that a manufacturer must hold a medical device licence before a case can be imported or sold here. In the United States the same object is described at 21 CFR 880.6250 as a disposable device worn on the examiner's hand or finger to prevent contamination, and it sits in Class I, where the premarket exemption written into the section is limited to finger cots subject to the limitations in section 880.9.
The practical consequence for a Canadian clinic is label and language rather than performance. Subsection 23(1) of the Medical Devices Regulations sets the minimum for a professional purchase at either English or French, while subsection 23(3) requires both official languages for information on a device sold to the general public, and paragraph 21(1)(c) requires the device identifier on the label. A case that carries a United States catalogue number, an English-only panel and no Canadian licence reference is a case that has to be relabelled before it can be sold here.
| Item | Canada | United States |
|---|---|---|
| Risk class | Class II | Class I under 21 CFR 880.6250 |
| Who holds the authorisation | Manufacturer holds the medical device licence | Manufacturer holds the clearance file; the codified exemption covers finger cots |
| Label language | English or French minimum; both official languages for general public sale | English |
| Device identifier | Required by paragraph 21(1)(c) | Required under the unique device identification rule |
| Expiry date on the label | Required if the device has one | Set by the manufacturer, not required by the section |
Is an exam glove tested the same way in Canada and the United States?
Both markets lean on the same ASTM test methods, and the difference sits in what each regulator does with the report. A Canadian buyer is relying on the manufacturer's licence, which Health Canada issues only after verifying safety and effectiveness and the quality management system, while a United States buyer relies on a premarket file and on the product code listed in the FDA classification database.
Two test claims need their own evidence. Watertightness is tested to D5151 under the D6319 specification, and a chemotherapy claim, which this range states on the Transform 100 and Protégé listings, rests on a cytotoxic permeation protocol of which ASTM D6978 is the standard reference. Asking which report sits behind a chemotherapy claim is a fair question to put to any supplier, and the answer should name the laboratory and the date.
Do Ontario and Quebec clinics order gloves in the same way?
The order mechanics are the same and the language surface is not. Ontario clinics work from Public Health Ontario's routine practices guidance and its clinical office practice guidance, which treat gloves as task-specific and single use and ask staff not to re-use or wash them; the employer duty behind that sits in section 25(2)(h) of the Occupational Health and Safety Act.
Quebec clinics work from provincial prevention references such as the provincial infection prevention and control guide and the standards and good practices document from the CIUSSS de la Capitale-Nationale, and beyond the clinical rule sits section 51 of the Charter of the French language, which requires every inscription on a product, its container or its wrapping, and on documents supplied with it including directions for use, to be drafted in French, with translations permitted but never given greater prominence.
| Item | Ontario | Quebec |
|---|---|---|
| Clinical rule for the glove | Single use for the task, discarded after the activity | Same rule in the provincial prevention references |
| Language on a clinic-made order sheet or poster | No provincial requirement beyond the federal minimum | French required, translation allowed but not more prominent |
| Recording the monthly check of stored stock | Named in the clinical office checklist | Covered by the clinic's own infection prevention and control procedures |
| Case build and sizing | One size per case everywhere in this range | Same |
How many cases should a clinic order for a year?
Thirty patient contacts a day, five days a week, forty-eight weeks a year is 7,200 contacts, and at two gloves per contact that is 14,400 gloves, or fifteen cases for the year. Split by size on a four-room clinic that runs mostly M and L, a workable annual order looks like eight cases of M, four of L, two of S and one of XL, reviewed after the first quarter because the size mix is the number clinics get wrong first.
Where the same clinic also runs cleaning rounds, the 6 mil case is a separate line and should not be blended into the examination count, because the glove leaves the shelf for a different reason and at a different rate. Buying the year in one delivery and storing it well is only sensible if the storage condition on the label can be met for the whole period; otherwise two deliveries a year cost less in spoilage than one large one.
Related reading
- How much does a year of Aurelia Transform 100 nitrile gloves cost a Manitoba long-term care home?
- What an ASTM D6319 test report tells a Canadian glove buyer
- How much does a year of examination gloves cost a two-chair Canadian dental practice?
- Which Canadian supplier will split glove orders across sizes in one shipment?
Frequently asked questions
Is 4.0 mil thicker than the glove most clinics use for examinations?
It is. A 3.2 or 3.5 mil film is the usual examination weight, and 4.0 mil adds wall for procedural work where an instrument is in hand. The Protégé case sits at that procedural point, and the thinner Transform 100 case is the same thousand-glove build one step down.
Does a chemotherapy claim mean the glove can be used with every cytotoxic?
It means the glove was tested against a cytotoxic permeation protocol, and the claim should name the report it rests on. ASTM D6978 is the standard that defines such a test. A clinic handling a specific drug should check that drug against the report rather than treating the claim as covering the whole class.
Can one case contain two sizes?
No, in this range every case is a single size. A clinic wearing M and L orders two cases, and a clinic needing a size split across one shipment should confirm that with the supplier before the order is placed rather than after the carton arrives.
Which case should a cleaning shift use?
The 6 mil heavy-duty case, because the glove is worn for the task rather than for a patient. At 0.15 mm the wall is roughly twice a standard examination film, and it is the format for disinfection rounds, waste handling and long cleaning shifts.
Does the case build change between Canada and the United States?
Not for this range, which is packed as ten boxes of 100 in both markets. What changes is the label and the authorisation behind it, because a Canadian sale depends on a medical device licence held by the manufacturer and on Canadian labelling, while the United States sale rests on its own pre-market file.
How should the cases be stored through the year?
As the storage condition on the label requires, which for a glove case means a closed cupboard away from heat and sunlight, in date order. A case that spends a summer against a window has not been stored the way its own label specifies, and the expiry date no longer describes what is on the shelf.
Which format does a laboratory bench need?
A 3.5 or 4.0 mil film is the working weight at a bench, with the thicker case where an instrument or a sharps container is handled. The specification to ask about is watertightness to D5151 under ASTM D6319, because a thin film that passes watertightness is a harder-working bench glove than a thick one that does not.
Putting the comparison on one order
The clinic supply and cost planner turns the annual case count above into a quarterly schedule, and the compliance log centre carries the free sterilization log sheet generator that clinics print alongside their glove and instrument records. For a standing order across several sites, the route is the institutional account enquiry page; where glove use has to be documented next to reprocessing practice, the sterilization compliance consultation page covers that side. Reselling? become a distributor.
CliniEco Medical distributes clinic consumables in Canada under MDEL #35334. This article compares formats listed on this site and describes requirements published by Health Canada, the Government of Ontario, the Government of Quebec and the United States federal register; the requirement that binds a specific clinic is the one in its provincial guidance, its accreditation conditions and its own written procedure.