How Many Class 5 Chemical Integrators Does a Diagnostic Laboratory in Ontario Use per Month, and How Many 200 per Pack Boxes Is That?

CliniEco Class 5 steam chemical integrator, 200-strip pack, with an ACCEPT and REJECT read window

A diagnostic laboratory in Ontario that runs about four autoclave loads a day uses roughly 84 Class 5 chemical integrators a month, which makes a 200-strip pack a two-and-a-half-month supply and a case of five packs a full year. The count follows loads, not specimens, and the reason a laboratory uses Class 5 integrators at all is the one thing a Class 1 tape cannot do: support the release of a load when the biological result is not back yet.

The integrator in this arithmetic is the CliniEco steam chemical integrator, a Class 5, ISO 11140-1 Type 5 strip packed 200 to a pack, with five packs to a case. It carries an ACCEPT and REJECT window rather than a simple colour change, which is what makes it a load-release document and not a decoration.

Quick facts on Class 5 integrator consumption, diagnostic laboratory

  • One integrator per load is the working rule, because the integrator is a load-level indicator placed in the most difficult position.
  • Four loads a day over 21 working days is 84 integrators a month, so a 200-strip pack lasts about two and a half months.
  • A case of five 200-strip packs is 1,000 strips, or about twelve months at that rate.
  • The integrator is read against an ACCEPT and REJECT reference, which is what distinguishes a Class 5 from a Class 1 process indicator.
  • Provincial guidance allows a Class 5 or 6 chemical indicator, together with the cycle physical parameters, to justify releasing a load where quarantine until the biological result is not possible.

CliniEco Class 5 steam chemical integrator, 200-strip pack, with an ACCEPT and REJECT read window

How many loads does a diagnostic laboratory decontaminate in a month?

The loads that matter here are the ones going through an autoclave, which in a community diagnostic laboratory are mostly waste loads, media preparation and the occasional instrument cycle. Specimen processing itself does not generate autoclave loads; what generates them is the requirement to decontaminate what leaves the bench.

Autoclave load type Loads per day Integrators per month (21 days) Notes
Waste decontamination 2 42 One integrator in the load, positioned in the least favourable spot
Media and reagent preparation 1 21 Cycle type differs from the waste cycle
Glassware and reusable items 0.5 10.5 Often grouped with media loads
Repeat or test loads 0.5 10.5 Bowie-Dick or commissioning cycles
Total 4 84 Plan on 84, buy on 100

Two factors move the monthly figure. The first is the number of cycle types: an integrator follows the cycle, so a laboratory running a gravity cycle for glassware and a pre-vacuum cycle for waste is running two monitoring lines even when the load counts are the same. The second is the waste volume, which in a laboratory that receives a high proportion of Category B specimens can push the waste loads from two a day to four, doubling the monthly total without changing the staff count.

How many 200-per-pack boxes is that in a year?

Integrators per month Per year 200-strip packs per year One pack lasts A case of five packs lasts
42 504 2.5, so 3 Five months About two years
84 1,008 5.04, so 6 Two and a half months About a year
126 1,512 7.6, so 8 Under two months About eight months
210 2,520 12.6, so 13 About a month Under five months

Read the case column as the stocking decision. A laboratory at four loads a day buys one case a year, which is a single purchase order and a single storage location, and a laboratory at ten loads a day buys two and a half cases a year. The pack size is generous for a small laboratory, which is why the pack, not the case, is the unit most labs reorder.

Why does a laboratory use Class 5 rather than tape or a Class 1 indicator?

Because the integrator answers a different question. A Class 1 process indicator, such as the tape on a wrapped package, shows that the package was exposed to a process. A Class 5 integrating indicator is designed to respond to all the critical variables of the cycle in an integrated way, and is read against a defined endpoint, so it can stand in for the question "did this load get the conditions it needed" in a way a colour change cannot.

That is exactly how provincial guidance uses it. Public Health Ontario's provincial document on cleaning, disinfection and sterilization describes quarantine of non-implantable items in processed loads pending the biological result, and adds that where load quarantine is not possible, evaluation of a Class 5 or Class 6 chemical indicator together with the specific cycle physical parameters may be used to justify the release of loads. For a laboratory that cannot hold a waste load for 24 hours waiting for a spore result, that sentence is the operating basis for the integrator.

It does not replace the biological indicator. A laboratory still runs biological monitoring of its autoclaves, and the integrator and the biological indicator answer at different times rather than one instead of the other: the integrator releases the load, the biological indicator verifies the process.

Case of five 200-strip Class 5 integrator packs, 1,000 strips in total

What governs a laboratory autoclave in Ontario, and what changes in the United States?

Item Canada (Ontario) United States
Laboratory licensing A laboratory operating under the Laboratory and Specimen Collection Centre Licensing Act, R.S.O. 1990, c. L.2, with the attendant quality requirements Clinical laboratory certification under the Clinical Laboratory Improvement Amendments, with accreditation layered over it
Sterilization guidance CSA Z314 series and Public Health Ontario's provincial reprocessing document CDC reprocessing guidance and AAMI standards
Waste leaving the site Ontario Regulation 347 for waste management, with the provincial biomedical waste requirements applied to the segregated stream State medical waste rules, with 49 CFR 173.199 for Category B infectious substances in transport
Integrator classification Sold as a medical device through a licensed distributor, classified as a Class 5 indicator under ISO 11140-1 Class II device under 21 CFR 880.2800, requiring 510(k) notification
Worker protection Occupational Health and Safety Act, R.S.O. 1990, c. O.1, with the regulation for health care and residential facilities 29 CFR 1910.1030 bloodborne pathogens standard

The first row is the one that surprises laboratories new to Ontario. The licence attaches to the laboratory and its quality system rather than to the autoclave, so the autoclave's monitoring programme is evidence that the laboratory's own procedures are being followed, not a separate regulatory track. That is why the integrator record matters as much as the strip: an integrator in a drawer with no cycle record is an indicator that proves nothing.

How should a diagnostic laboratory stock and record integrators?

Stock one pack in use and one in reserve, and record the integrator against the load. At four loads a day that is two packs on the shelf, which is five months of buffer at the reserve rate and enough to absorb a delivery delay without changing practice. At ten loads a day the same two packs are two months, and the reorder point moves to "when the reserve pack is opened".

The record is where a laboratory earns the release decision. For each load, record the cycle number, the cycle type, the integrator lot and result against the ACCEPT and REJECT reference, and the physical parameters the cycle printed. Keep failed integrators and the action taken, because a record of passes only is not a monitoring programme. Two smaller habits are worth adding: store the strips in their sealed pack away from heat and light, and never use a strip from an opened pack that has been sitting in a warm room for a year, because an integrator's ink ages like any other chemical indicator.

Three steps are worth taking now. The clinic can print a monthly consumable count and reorder sheet from the compliance log centre, which is also where the sterilization log generator sits for any sterilizer on site. Where the numbers need to be checked against the clinic's own records, the sterilization and infection control consultation page is the route in, and multi-site groups can price a year of supply through the institutional account enquiry page. Reselling? become a distributor.

Related Reading

References

Frequently Asked Questions

How many Class 5 integrators does a laboratory use in a year?

About 1,000 at four loads a day, which is five 200-strip packs. A laboratory running ten loads a day uses about 2,500, or thirteen packs, and should be buying in cases rather than packs.

Can a Class 5 integrator release a load without a biological result?

Provincial guidance allows a Class 5 or Class 6 chemical indicator, together with the cycle's physical parameters, to justify releasing a load where quarantine until the biological result is not possible. It is a release decision, not a substitute for biological monitoring.

Where should the integrator go in the load?

In the position that is least favourable to steam penetration, which is normally the centre of the densest part of the load or the tray that is hardest to reach. An integrator placed on the outside of a package tests the chamber, not the load.

Is a Class 5 integrator the same as autoclave tape?

No. Tape is a Class 1 process indicator that shows exposure to a process. A Class 5 integrating indicator responds to the critical variables of the cycle and is read against a defined endpoint, which is why it can support a load release decision.

How should integrators be stored?

In the sealed pack, flat, away from heat and light, and used within the shelf life printed on the pack. An opened pack left in a warm room ages, and an aged indicator can read ambiguously.

Does an Ontario laboratory need to keep integrator records?

Yes, as part of the quality system behind the laboratory's licence and accreditation. The useful record pairs each integrator with its cycle number, cycle type, lot, result and the cycle's physical parameters.

Consumption figures in this article are planning assumptions built from named inputs and are not clinical, legal or regulatory advice. Requirements quoted here were published as described at the time of writing and are amended from time to time, so confirm them against the instruments in force for your jurisdiction. Load counts vary with the laboratory's specimen mix and waste volume; the four-load model is a planning assumption, not a measurement of a named laboratory. CliniEco Medical distributes medical consumables under MDEL #35334.