Which single-use laboratory supplies does a Canadian fertility clinic need for an IVF cycle?
Which single-use laboratory supplies does an IVF cycle consume?
The clinical side of an IVF cycle gets the attention; the laboratory side is where the single-use volume actually sits. One patient cycle passes through four stages, and each stage opens its own consumables: monitoring and preparation, the retrieval itself, fertilisation and culture, and the transfer appointment afterwards.
The list that follows is the laboratory-bench list, not the procedure-room list. The sterile 100 by 15 mm polystyrene petri dishes, 500 per case and the sterile 15 mL centrifuge tubes, 500 per case are the two lines an embryology bench reorders most often, because both are opened at more than one stage of the same cycle.
Where does each consumable sit in the cycle?
| Stage | What is opened | Single-use item | Pack size we stock | What the record needs |
|---|---|---|---|---|
| Monitoring and preparation | Semen collection container, gloves, wipes | Sterile specimen cup | 600 cups per case | Date, patient identifier, collection time |
| Retrieval | Follicle aspirate handling, wash steps | Sterile centrifuge tubes 15 mL and 50 mL | 500 per case | Lot number, tube count |
| Fertilisation and culture | Holding and fertilisation dishes, ICSI dishes | Sterile petri dish 100 x 15 mm | 500 per case | Lot number, dish count |
| Media handling | Media transfer, aliquoting | Serological pipettes and parafilm | Case of mixed sizes | Lot number per media batch |
| Transfer | Preparation bench and documentation | Sterile specimen containers, filtered tips | 200 per case, racked | Lot number per transfer day |
A single retrieval usually opens between six and a dozen dishes once wash, fertilisation check and culture are counted, and a similar number of tubes. That is the figure to use when a clinic converts a monthly cycle count into a case order, rather than the number of patients.

Which items are usually missed on the order form?
Three, in our experience. The first is the collection container: clinics order culture dishes carefully and then use whatever sterile cup is in the cupboard, without checking whether the lot documentation travels with it. The graduated 90 mL specimen cups, 600 per case are a sterile option for that step. The second is the second tube size. A laboratory that stocks only 15 mL tubes will improvise when a protocol calls for 50 mL, and improvised handling is where labelling gaps start.
The third is the pipette tip class. Media work and sperm preparation both draw small volumes, and a filtered tip used for handling is a different purchase decision from a non-filtered tip at the same volume. If the laboratory has not separated those two lines, the filter tends to be used where it is not needed and missing where it is.
What changes when a clinic handles donor gametes?
The consumables stay the same; the obligations change. The Safety of Sperm and Ova Regulations (SOR/2019-192) set out donor suitability assessment, labelling and record requirements for donated sperm and ova in Canada, and those obligations attach to the donation rather than to the disposable item. In practice the laboratory feels it as extra labelling on stored samples and a longer record trail, not as a different dish.

Autologous cycles sit outside that regulation but not outside the clinic's own procedures. The practical question for the buyer is whether the laboratory's SOP names the consumable at each step at all. When a deviation is reviewed later, an SOP that says "culture dish" without a lot number leaves nothing to check.
How do you keep lot records per patient cycle?
Enter the lot number at the point of use, not at the end of the day. The case label carries the lot, the expiry date where one applies, and the sterility statement; photograph or transcribe it when the case is opened and write the number into the patient cycle record. Two clinics can use the same case and need the same lot number in two different files, and only the bench record links them.
The second half of the discipline is the store itself. A case that has been opened and returned to the shelf without a date on it is a lot record you can no longer trust, which is why the printable sheets in the link above carry a date field next to the lot field.
Where to buy laboratory consumables in Canada
The culture and dish lines sit in the inoculation and culture collection, tubes and freezing consumables in the centrifuge tube and freezing collection, and pipetting supplies in the pipetting and transfer collection. Laboratory buyers comparing formats across a clinic group can see the wider range on the laboratory consumables page.
Ordering for a fertility clinic, a network of satellite sites or a hospital-based laboratory? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
References
- Safety of Sperm and Ova Regulations, SOR/2019-192, Department of Justice Canada (checked 23 November 2026)
Printable companion: the lot and receipt templates give each case a field for the lot number and the date it entered the laboratory store.
Working out how many cases a year the laboratory needs? The clinic supply planner converts cycles per month into dishes, tubes and pipette cases.
Related Reading
- Fertility Care Supplies: Disposable Consumables for IVF Clinics
- How Should a Fertility Clinic Segregate Biomedical Waste in Canada?
- Which Pipette Tips Does a Canadian Research Laboratory Reorder Monthly?
Frequently Asked Questions
Are general-purpose sterile dishes acceptable in an embryology laboratory?
Only if the manufacturer supplies an embryo toxicity statement for the lot. Dishes sold as sterile laboratory consumables are not automatically embryo-tested, and the lot documentation is what a laboratory quality reviewer asks to see.
How do the supplies differ between a stimulated cycle and a natural cycle?
A stimulated cycle opens more monitoring consumables and more culture vessels because there are more oocytes to handle. The single-use list itself does not change, but the quantities per patient roughly follow the number of oocytes collected.
Do donor gametes change the supplies a clinic needs?
The consumables are the same, but the paperwork is not. Donor sperm and ova bring the Safety of Sperm and Ova Regulations into play, which adds donor suitability assessment and labelling and record obligations to the cycle.
How long should a laboratory keep the lot record for a cycle?
Keep it at least as long as the patient record it supports. Because the cycle record can be reviewed long after the delivery, the lot number stamped on each case should be entered into the patient file at the time of use rather than reconstructed later.
Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).