What makes the electrolysis probe record defensible if an inspector questions it at an Ontario medical aesthetics clinic?

Boxes of black nitrile examination gloves stacked beside an open dispenser

What makes the electrolysis probe record defensible if an inspector questions it at an Ontario medical aesthetics clinic?

An inspector asks for the electrolysis file and gets a sheet of ticks with the words "wiped between clients". That sheet is not a record of anything: no product, no concentration, no date of preparation, and nothing connecting a needle to a client.

The defensible version is built from two documents that already exist in a compliant treatment room, joined at the client line.

What makes an electrolysis probe record defensible?

Four properties: the right fields, the right instrument, a traceable signature, and a storage location that survives staff turnover.

Electrolysis is named in the Act itself: subsection 1 (1) of the Health Protection and Promotion Act lists it among the services covered where there is a risk of exposure to blood or body fluids, so the regulation applies to an electrolysis room in full.

A canister of hydrogen peroxide disinfecting wipes with the label facing forward

Which two records does an inspector read together?

The disinfection record and the invasive procedure record. Section 14 (1) of O. Reg. 136/18 requires the first to carry the name of the disinfectant, its concentration, the date it was prepared where applicable, and the date by which the solution must be discarded. The second has to carry the procedure and the part of the body, the client's name and contact information, the provider's name and contact, the dates, and the lot numbers and expiry dates of the pre-packaged sterile equipment used.

Read together, they answer the only question that matters: was the needle sterile and traceable, and was the holder disinfected with a product still inside its usable life.

Record Legal hook Fields that have to be there
Disinfection entry s. 14 (1) 2 Product name, concentration, date prepared, discard date
Needle entry s. 14 (1) 3 vi Lot number and expiry of the sterile needle
Client line s. 14 (1) 3 i to iii Procedure, body area, client contact, provider contact
Product number s. 11 (2) Disinfectant carries a DIN or NPN

Boxes of black nitrile examination gloves stacked beside an open dispenser

What has to be written for a reusable probe holder?

The holder is reusable equipment that is not introduced into the body, so section 10 (4) gives two routes: clean and disinfect it between each use, or cover it with a single-use disposable cover intended to prevent infection and discard the cover after each use. Whichever route the clinic takes, the record has to show it: a cover log without the cover change is as thin as a disinfection log without the discard date.

The needle side is less forgiving: section 10 (6) requires sharps used for invasive procedures to be sterile and single use, from packaging not previously opened, damaged or compromised. A needle drawn from an open tray cannot be recorded as compliant.

How long does the record have to stay retrievable?

Section 14 (2) sets a two-stage clock. The records are stored at the setting, in a secure location, for one year or until the setting ceases to operate, whichever comes first, and then retained and kept readily available for at least two years after that period ends. In practice three years of retrievability, with the first year on site.

The common failure is not a missing log but a complete one that cannot be produced, because it lived in a binder that left with the last manager. Disinfectant selection for a treatment room sits in cleaning and disinfecting, and the inspection-facing route for an aesthetics practice is the medical aesthetics supply line.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. O. Reg. 136/18, Personal Service Settings, under the Health Protection and Promotion Act (checked 26 November 2026)
  2. Health Protection and Promotion Act, R.S.O. 1990, c. H.7, subsection 1 (1) definition of personal service setting (checked 26 November 2026)
  3. R.R.O. 1990, Regulation 562, Food Premises, revoked 1 July 2018 by O. Reg. 493/17, section 48 (checked 26 November 2026)
Printable companion: the compliance log library includes a disinfection record sheet with product, concentration, prepared date and discard date columns. Building the whole file rather than one page? The clinic supply planner maps the records a treatment room needs against the products that generate them.

Related Reading

Frequently Asked Questions

Is the electrolysis needle part of the probe record?

Yes. The needle is a sharp used for an invasive procedure, so the record carries its lot and expiry, and its packaging has to have been unopened.

Does the clinic have to keep the record on paper?

No format is prescribed, only where it is kept, that it is secure, and that it can be produced for a medical officer of health or public health inspector on request.

Was this ever covered by R.R.O. 1990, Reg. 562?

No. Regulation 562 under the Health Protection and Promotion Act is the Food Premises regulation, revoked on 1 July 2018 by O. Reg. 493/17. Personal service settings are governed by O. Reg. 136/18.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).