Dental Ultrasonic Cleaner for Dental Clinics in British Columbia: Sizes, Specs and What to Order
A dental surgery in British Columbia that adds a second chair discovers the tank problem on a Monday morning: two loads of instruments, one tank, and a hygienist waiting. The fix is choosing between three sizes that look close on paper and behave differently in use.
The CliniEco CD-4862 dental ultrasonic cleaner is the 6 L unit, sized so a standard instrument cassette fits in one cycle, with five fixed temperature presets between 40 °C and 60 °C and a 1 to 30 minute timer. The presets matter: the number set is the number recorded.
Which tank size does a dental clinic actually need?
The choice turns on the load, not the litre badge.
| Unit | Tank | Working volume | Frequency | Power |
|---|---|---|---|---|
| CD-4862 | 6 L | 6,000 ml | 35 kHz, two transducers | 260 W |
| CD-4875 | 7.5 L | 6,000 ml | 35 kHz | 380 W |
| CS8.0 | 8 L | 7,000 ml, 3,600 ml minimum fill | 49 kHz | 450 W |

The 6 L class is the size at which one cassette fits in one cycle with the lid closed; the tank opening of 32.5 × 20.4 × 9.9 cm takes an instrument up to 34 cm long. The 7.5 L unit keeps the same 6,000 ml of working volume and adds shell: longer trays fit and splashing stays inside, but it does not buy a second cassette. The 8 L CS8.0 is the one that changes the load: 7,000 ml of working volume holds two chairs of instruments in one cycle.
What is the difference between nominal and working volume?
Nominal volume is the shell; working volume is the liquid you can use without the basket sitting proud of the surface. Between 6 L and 7.5 L the nominal figure moves by a litre and a half while the working figure does not move at all, which is exactly the detail a purchase order gets wrong when it is written from a brochure.
Read the working volume row first, then the minimum fill. An 8 L tank run at 3,600 ml is not doing 8 L of work, and filling a large tank to the brim to "use the capacity" heats water no instrument touches.

What are the CD-4862 specifications?
The 6 L unit runs at 35 kHz from two industrial-grade transducers, draws 260 W on a 100 to 120 V, 60 Hz supply and fits a North American plug. The timer covers the full 1 to 30 minute range rather than a set of fixed cycles, and the five presets sit at 40, 45, 50, 55 and 60 °C.
Those presets are the difference between this unit and a tank with a rotary thermostat: a dial is read approximately and a preset is read exactly, so a set-point recorded per cycle can be compared week to week.
Does an ultrasonic cleaner replace anything else in the workflow?
No, and this is where catalogue copy and clinical practice part company. The cleaner removes soil, including cement residue, polishing paste and dried blood in hinges and threads, as one step in instrument reprocessing. It makes no microbicidal claim and replaces no later step.
ISO 15883-1 treats cleaning equipment as something whose performance is defined and tested rather than assumed, and the same logic applies at the chair: the instrument manufacturer's instructions for use, not the cleaner's sheet, decide what happens after the tank.
Equipping a dental practice? See our dental practice supplies, and the ultrasonic cleaners collection lists the units held in stock.
Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
References
- ISO 15883-1:2024, washer-disinfectors, general requirements (checked 26 November 2026)
- Medical devices, Health Canada regulatory overview (checked 26 November 2026)
- Medical Devices Regulations, SOR/98-282 (checked 26 November 2026)
Related Reading
- Choosing an Ultrasonic Cleaner Tank Size for a Canadian Dental Clinic
- Benchtop Ultrasonic Cleaner vs Washer-Disinfector: When to Upgrade
- Dental Instruments in the Ultrasonic Basket: Hinged Positioning
Frequently Asked Questions
What is the difference between nominal and working volume?
Nominal is the tank shell, working volume is the liquid you can actually use. The 7.5 L unit holds 7,500 ml nominally but 6,000 ml of working volume, which is the same usable load as the 6 L class.
Does a bigger tank hold more instruments?
Not by itself. Two cassettes need the working volume and the tank opening for two; a 7.5 L shell with 6,000 ml of working volume buys headroom, not a second cassette.
Which frequency is easier on hinged instruments?
Higher frequency makes smaller bubbles, which reach threads and hinges more gently. A single 49 kHz unit is the easier choice for plated and hinged work; a 35 kHz dual-transducer unit moves heavier soil faster.
Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).