Which Mouth Mirrors and Periodontal Probes Should a Quebec Dental Clinic Buy? Selection Checklist
A Quebec operatory ran short of probes on a Tuesday. The cassette came back from the sterilizer holding three mirrors and a single probe, and the afternoon was a perio maintenance list that needed pocket depths at every site.
What belongs in a diagnostic cassette before the order is placed?
The cassette is what gets ordered and what gets reprocessed, so it is the right unit to count. A working diagnostic set is a mirror, an explorer, a probe and a pair of tweezers, and a room with two of each never stops the schedule to wait for the sterilizer.
None of those instruments is a CliniEco line. What travels with them is the packaging they return in, and that is what a practice reorders in volume: the CliniEco sterilization pouches — Class 4 self-sealing, dual indicator, 200 per box for single instruments, plus the CliniEco autoclave indicator tape — three-roll set for cassettes and wrapped trays.
Which mirror should the order line name?

Three things go into the wording of a mirror order line. Head size, numbered small to large, with size 4 carrying routine adult work and the smaller heads going to children and narrow arches. The reflective surface, because a front-surface rhodium mirror gives one image while standard glass can show a second image from the glass beneath. And the mount, because a cone socket mirror needs a cone socket handle.
Coating is where the purchase decides the running cost. Steam reaches the edge of the reflective layer, and once moisture creeps under it the mirror clouds. The coating, not the backing metal, sets how many cycles a mirror survives.
Which probe marking scheme should a practice standardise on?
A probe is bought by its markings, and a practice with three schemes gets three readings of the same site. Pick one for charting.

| Scheme | What the markings are | Where it earns its place |
|---|---|---|
| UNC-15 | Millimetre marks to 15, with 5, 10 and 15 emphasised | Full-mouth charting |
| Williams | Marks at 1, 2, 3, 5, 7, 8, 9, 10 | Posterior pockets |
| Marquis | Colour bands at 3, 6, 9 and 12 mm | Fast screening |
| WHO / CPITN | 0.5 mm ball tip, bands at 3.5, 5.5, 8.5, 11.5 mm | Screening rounds |
| Naber | Curved shank with millimetre marks | Furcation |
Why do two probes with different tip diameters disagree?
ISO 21672-1:2012 sets the general requirements for periodontal probes and ISO 21672-2:2012 covers the designation of working ends; both were confirmed in 2023 and both are current. The standard makes visible that a probe is defined by its working end, not only by its markings. A blunt tip of about 0.4 mm reads the coronal edge of the junctional epithelium, while a thinner tip travels further into the same sulcus and returns a larger number. Neither reading is wrong, which is why one design per practice belongs in the chart.
How many mirrors and probes does an operatory need?

Three mirrors and two probes per chair is the working rule, and it comes from the cycle rather than the drawer. One mirror is in a hand, one is in the sterilizer, one is the spare that keeps the schedule moving. Probes follow the same arithmetic with one less spare.
How does ODQ guidance set the record in Quebec?
The Ordre des dentistes du Québec publishes the province's reprocessing expectations in its lignes directrices, revised in February 2026. Each sterilizer needs a process challenge device with a biological indicator and a Type 5 chemical indicator, recommended daily and required weekly for every cycle type in use, packaged and unwrapped counted separately. The air removal test is daily, applies to Class B only, and cannot run in the same cycle as the other test.
Mirrors and probes carry coatings and hinges, so their manufacturer's instructions — written to ISO 17664-1:2021 — decide whether they can be steam sterilized and at what temperature. The record goes into the registre du stérilisateur described in Annexe 5.
Does the paperwork have to be bilingual?
Bilingual labelling is federal and attaches to the device: medical device labels and instructions for use carry English and French under the Medical Devices Regulations. For chemistry, WHMIS adds a bilingual supplier label and safety data sheet, so an ultrasonic solution with English-only documents is an incomplete paper set.
What else goes on the same order?
The reprocessing loop around the cassette is where CliniEco sits. A diagnostic instrument needs a cleaning step before it is packed, which is the CliniEco ultrasonic cleaner — 6 L benchtop, dual frequency 32/48 kHz with the CliniEco ultrasonic multi-enzyme cleaning solution — low-foam concentrate, 1:400 in the bath, and a monitoring answer at the other end, which is the CliniEco 24-hour biological indicators — 25-pack.
Running a dental practice? See our dental practice supplies and reprocessing lines.
Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
References
- ISO 21672-1:2012 — Periodontal probes, Part 1: General requirements (checked 31 October 2026)
- ISO 21672-2:2012 — Periodontal probes, Part 2: Designation of working ends (checked 31 October 2026)
- ISO 17664-1:2021 — Processing of medical devices, Part 1 (checked 31 October 2026)
- ISO 17665:2024 — Moist heat sterilization (checked 31 October 2026)
Printable companion: the free record sheet centre prints a sterilizer log with the columns the registre du stérilisateur expects, so the week is written down as it happens.
Size the order to the chair count with the clinic supply planner, which converts operatories into a per-cycle quantity.
Not sure how this applies to your own setup? Ask a sterilization compliance specialist — you’ll get a written answer specific to your equipment and province, with the regulation or standard cited.
Related Reading
- Mouth Mirrors: Head Size, Coating and How Many Steam Cycles a Mirror Survives
- Periodontal Probes: Markings, Tip Diameter, ISO 21672
Frequently Asked Questions
Which mirror size should an adult operatory order?
Size 4 is the one routine adult work uses; smaller heads are for children and for posterior access on a tight arch. Order the handle separately, because a cone socket mirror needs a cone socket handle.
Do all periodontal probes read pocket depth the same way?
No. The markings decide how a depth is read and the working-end diameter decides how far the tip travels, so two designs can disagree by a millimetre on the same site. One scheme per practice keeps charting comparable.
Can mouth mirrors be sterilized in a steam autoclave?
Most metal-backed mirrors can, and the coating sets the service life rather than the metal. A front-surface rhodium mirror lasts longer than standard glass, where moisture works in behind the reflective layer.
Is biological monitoring weekly or daily in Quebec?
The ODQ guidance recommends a process challenge device with a biological indicator daily and requires it weekly for each cycle type actually used. Packaged and unwrapped cycles are separate types.
Last updated: October 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).