CliniEco Medical Steam Chemical Integrator — Class 5, ISO 11140-1 Type 5 | 200 & 1,000 Strip Packs
Specifications
| Type | Chemical integrator |
|---|---|
| Class | Class 5 |
| Standard | ISO 11140-1 Type 5 |
| Pack quantity | 200 or 1,000 strips |
| Available formats | 200/pack · Case of 5 × 200 · 1,000 |
| Use | Steam sterilization monitoring |
| SKU | CLI-STER-CI-100-CASE10 |
Pricing
| Order | Unit price |
|---|---|
| 1 box | $79.00 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 16 sections · specs, use, compliance
CliniEco Medical Steam Chemical Integrator — Class 5, ISO 11140-1 Type 5
ISO 11140-1 Type 5 integrating indicator for steam sterilization — 200 or 1,000 strips per pack, 121–135 °C, yellow-to-black read. An integrating indicator responds to time, temperature and saturated steam in a single pass/fail window, so every pouch, bag or tray carries its own in-pack check and a load can be released the same day without waiting on an incubation result. It supplements — and does not replace — the biological indicator used in your daily spore test. Supplied by CliniEco Medical, Health Canada licensed importer and distributor (MDEL #35334), with a lot-level CoA available on request.
Class 5 Indicators for Sterilization. If that is the search that brought you here, this is the strip it refers to: a Class 5 Chemical Indicator in ISO 11140-1 Type 5 form, read inside the pack rather than printed on the outside of it, so the pass window belongs to that one pouch, bag or tray. It is supplied as a 200-strip pack, and as a case of 5 × 200 for clinics that keep a working pack on the shelf and the rest in stores.
How to use the integrator
- Place one in every pack. Put a single integrator inside each pouch, bag or tray before it is sealed. In a rigid container, place one in each corner — or at least two diagonally opposite corners — so the strip reads the path steam actually took.
- Load and run a validated steam cycle. The strip is formulated for 121–135 °C and reads gravity, pre-vacuum and immediate-use cycles; use it inside the cycle your sterilizer is validated for, not as a substitute for that validation.
- Read it straight out of the chamber. The ink front must travel into the ACCEPT window and match the black reference on the strip. A front that stops short is a reject: hold the load, do not release it, and re-run the cycle after the cause is corrected.
- Record the result before the load leaves. Enter the date, sterilizer ID, cycle number and pass/fail on the load log, and file the strip with that record — an inspector reads the log and the strips together.
- Keep the biological indicator schedule. A Type 5 strip releases the load; it does not replace the spore test. Daily (or per your provincial requirement) biological indicator monitoring continues unchanged.
CliniEco Service Promise
- Free shipping over $99 in Ontario · $199 rest of Canada (Ontario) / $199 (rest of Canada) (Ontario)
- Orders dispatched within 24h (Toronto)
- Canadian-owned company
What is an ISO 11140-1 Type 5 integrator, and how does it differ from tape or a Class 4 indicator?
ISO 11140-1 sorts chemical indicators by what they measure. Class 1 is a process indicator such as autoclave tape, which only shows that a pack went through a cycle. Class 3 responds to a single variable and Class 4 to two or more. Class 5 — Type 5 in the standard's own numbering — is the integrating indicator: time, temperature and saturated steam are read together in one window, and the strip is designed so that an accept result corresponds to the lethality a biological indicator would demonstrate in the same cycle. That is the practical difference from a Class 4: a Class 4 tells you more than one variable was present, while a Type 5 is calibrated to stand in for the outcome.
Does a Type 5 strip replace the biological indicator?
No, and treating it that way is the mistake the classification exists to prevent. An integrator is an in-pack check that can run on every load, which is what a biological indicator cannot economically do. A spore test answers a different question — did the cycle actually kill organisms — and is run on a schedule, plus for every load containing implants. If you are setting the frequency for your own sterilizers, ask a sterilization compliance specialist what your college expects rather than copying another clinic's schedule, and pair the strips with a 24-hour biological indicator for the periodic test.
How many strips does a year of loads use, and what does it cost?
| Order | Strips | Price |
|---|---|---|
| 200/pack | 200 | $17.99 |
| Case of 5 × 200 · 1,000 | 1,000 | $79.00 |
One strip per pack is the point of the product, so the count follows the pack count. Twenty packs a day over 240 working days is 4,800 strips: twenty-four packs of 200, or just under five cases of 1,000. Each of the two order formats is priced on this page, and the per-strip figure follows from each pack amount by dividing; the case works out lowest per strip, and the 200/pack sits between the two — the sensible middle for a clinic that does not want a thousand strips on the shelf at once.
Which cycles will a Type 5 strip read?
The page specifies 121°C to 135°C, covering gravity-displacement, pre-vacuum and immediate-use cycles. What changes between them is the time and the air removal, and the strip is built to respond across that band rather than to a single set point — which is why one SKU can serve a clinic with a gravity sterilizer in one room and a pre-vacuum unit in another. It does not make the strip a substitute for the daily air-removal test on the pre-vacuum machine: that is still a Bowie-Dick pack, ISO 11140-5 Type 2.
How is the strip read and written up?
Read the moving front against the printed accept and reject zones after the cycle has finished, once the pack is cool enough to handle — the ink front is still travelling while the pack is hot, and a window read mid-move is not a reading. Then write it down: strip lot, cycle number, sterilizer ID, date and result. Print the load record sheet or build one with the log generator so the strip result and the pack contents sit on the same line. Store the box sealed and away from heat, and keep the lot number from the box for the record.
Product Specifications
| Attribute | Specification |
|---|---|
| Product | Steam Chemical Integrator (Chemical Indicator, Class 5) |
| Standard | ISO 11140-1:2014 — Type 5 integrating indicator |
| Strip Size | 2″ × 0.75″ (50 × 19 mm) standard; extended-length option available |
| Pack Size | 200 strips / pack · 1,000 strips / case (5 × 200) |
| Parameters Monitored | Time + temperature + saturated steam penetration (multi-parameter) |
| Cycle Compatibility | 121–135°C steam sterilization — gravity, pre-vacuum and immediate-use (IUSS) cycles |
| Readout | Moving-front window: ink migrates from REJECT to ACCEPT zone when all parameters are met |
| Result | Immediate pass/fail — no incubation required |
| Shelf Life | See the expiry date printed on each pack |
| Intended Use | In-pack monitoring for dental, veterinary, laboratory and medical facilities |
| Distribution | CliniEco MDEL #35334 |
Features
- ✓ A same-day, in-pack read for every load — the strip responds across 121 °C, 128 °C and 135 °C, so a load can be released or held without waiting on an incubation result. It does not replace a biological indicator: periodic spore testing still applies.
- ✓ Three critical parameters in one strip — time, temperature and saturated steam; a single ink front confirms all were met
- ✓ Unambiguous pass/fail window — dark bar must enter the ACCEPT zone; eliminates guesswork compared with single-parameter Class 1–4 indicators
- ✓ Laminated construction — plastic-coated strip resists moisture and handling damage inside the pack
- ✓ Place inside every pack or tray — use with sterilizer trays, cassettes, wrapped packs and peel pouches
- ✓ No equipment lock-in — works with any steam autoclave; no reader or incubator required
Quality & Compliance
- ISO 11140-1:2014 Type 5 (third-party tested)
- Distributed by CliniEco Medical
Clinic & Volume Pricing
- Volume pricing is available on request — contact alina@clinieco.ca.
- Free shipping over $99 in Ontario · $199 rest of Canada (Ontario) / $199 (rest of Canada)
- No minimum order — buy 1 box or a case
Why Clinics Choose CliniEco
- Lower cost per strip than 3M/Crosstex integrators at comparable Type 5 performance — confirm each supplier's current list pricing before you compare
- Factory-direct pricing — no distributor mark-ups
- One supplier for the full sterilization line — pouches, rolls, tape, indicators, biological indicators and BD test packs
Clinic & Volume Orders
Looking for 500-strip bags, private-label branding or standing monthly volume? Contact us for pallet pricing and priority restocking: Request a B2B Quote.
💡 Pair It With Your Sterilization Routine
Combine with CliniEco Sterilization Pouches, Autoclave Tape and Biological Indicators to cover every load — or explore the full Sterilization Monitoring collection.
Related articles
- ISO 15882 in Practice: Selecting, Storing and Reading Chemical Indicators
- How do I know if my autoclave is working properly?
- Chemical Indicator Strips Price in Canada: What Drives Cost per Pack
- Chemical Indicators Class 4 vs Class 5 vs Class 6: Which Do Canadian Clinics Order
A set quantity of integrators every month, with the biological indicators and Bowie-Dick tests that go with them: a fixed monthly quantity of Class 5 integrators in one pack.
Common questions
What is a Class 5 chemical integrator?
A Class 5 integrator (ISO 11140-1 Type 5) is a multi-parameter chemical indicator that responds to all critical variables of a steam sterilization cycle — temperature, time and steam quality. It's the closest chemical equivalent to a biological indicator.
How is a Class 5 integrator different from Class 4?
Class 4 indicators respond to two or more critical variables; Class 5 integrators respond to ALL critical variables. Class 5 provides a higher level of cycle verification confidence, which is why many dental offices use them for every load.
Do I still need biological indicators if I use Class 5 integrators?
Yes. Biological monitoring is required on top of chemical indicators: in Ontario the RCDSO requires a biological indicator for each sterilizer on every day it is used (daily), and the CDC / AAMI ST79 weekly baseline applies in most US states. Class 5 integrators provide per-pack, per-cycle verification in addition.
What cycles can this integrator monitor?
Steam cycles from 121°C to 135°C, including gravity displacement, pre-vacuum and IUSS (flash) cycles.
Does this need a Health Canada device licence?
Chemical indicators are Class I devices in Canada, distributed under our Medical Device Establishment Licence (MDEL #35334).
How do I read the integrator after a cycle?
After sterilization, compare the indicator strip to the reference colour. A pass means the internal indicator has changed to the 'Accept' colour, confirming all critical parameters were met.
How many integrators are in a pack?
Each box contains 200 Class 5 steam chemical integrators (a case holds 5 × 200 = 1,000), sufficient for daily monitoring in a busy dental practice for several months.
Is the integrator ISO compliant?
Manufactured and tested to ISO 11140-1 (Type 5). Manufacturer documentation available on request.
