What par level of 95 kPa specimen bags should a Canadian clinic hold?

CliniEco 6 x 9 inch 3-wall specimen transport bag, 1,000 bags per case

What par level of 95 kPa specimen bags should a Canadian clinic hold?

A four-physician clinic in Brampton sends 60 specimens to the laboratory every weekday, and roughly half of them are urine. The bags are the smallest line on the purchase order and the one that stops a shipment when the shelf is empty, so the par level is worth an hour once a year.

Most clinics standardise on the UN3373 specimen transport bag in 6 × 9, 7 × 11, 8 × 10 and 12 × 15 inch formats, with a document pouch and an absorbent pad built in. The question is how many of each.

How many bags does one accession consume?

One bag per accession, plus a resend allowance. The allowance is your measured rejection rate. A clinic rejecting four specimens in a hundred runs a factor of 1.04; one that runs at fifteen in a hundred runs 1.15. Multiply accessions per day by that factor and you have bags per day.

For the Brampton clinic: 60 accessions × 1.15 = 69 bags a day, 345 a week on a five-day collection schedule.

What does 95 kPa actually describe?

Specimen transport bag printed 95kPa with biohazard label, peel-and-seal strip and closing instructions

It describes the completed package, not one sheet of film. The pressure differential test in Packing Instruction 650 is applied to primary receptacle, absorbent and secondary bag together, along with a drop test, and the whole assembly is what gets documented. A bag printed 95 kPa has been tested in that role, which is why the printed closing procedure matters: specimens and absorbent go through the slit, the bag is folded on the lines, and the folded requisition goes in the rear pouch.

That last step is the one clinics skip. A requisition taped to the outside is not inside the package, and it does not travel as part of it.

Which size should the par cover?

Size mix empties a shelf, not total count.

Size What it usually carries Where it fits
6 × 9 in two to four blood tubes, swabs highest count, daily draws
7 × 11 in one urine container with a tube the working size in most clinics
8 × 10 in paired samples and larger containers panels sent together
12 × 15 in several containers from one patient batch pickups, low count

CliniEco 6 x 9 inch 3-wall specimen transport bag, 1,000 bags per case

Stocking only 7 × 11 means double-bagging the 12 × 15 jobs and running out of the middle size.

How do you turn daily volume into a reorder point?

Two weeks of cover minus lead time. At 345 bags a week, two weeks is 690; with a five-day supplier lead time, the reorder point sits near 500 bags, and a case of 1,000 covers roughly three weeks of the mixed sizes. Order the size mix in the same proportion you actually use it, or the largest format becomes shelving.

What changes the number?

Collection days, not patient volume. A clinic that collects five days and ships three needs a week of buffer on the shelf; one with a daily courier pickup can run thinner. Holiday weeks are the real test: a Thursday pickup moved to Monday turns into four days of samples and one full shelf.

Ground shipments from a clinic usually travel in the 6 × 9 inch three-wall leak-resistant specimen bag, with the 95 kPa format reserved for anything that flies. Both take the same 90 mL graduated sample cups, so the par sheet lists them together.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

Running a family practice? See our family practice clinic supplies.

References

  1. Guidance on regulations for the transport of infectious substances 2021-2022, World Health Organization (checked 12 November 2026)
  2. Transportation of Dangerous Goods Regulations, SOR/2001-286 (consolidated text) (checked 12 November 2026)

Printable companion: the free specimen rejection log is the other half of the par level: every rejected bag is a bag to replace.

Want the arithmetic done for your own accession count? The clinic supply and cost planner takes collections per day and returns packs per month.

Related Reading

Frequently Asked Questions

Do I need 95 kPa bags if a courier drives the specimens to the lab?

The 95 kPa test belongs to air transport of Category B specimens. Ground movement in Canada is governed by the dangerous goods rules for packaging, where a three-wall leak-resistant bag with an absorbent pad is the common clinic format. If any part of the journey may fly, stock the 95 kPa format.

Can two patients' specimens travel in one bag?

No. One accession per bag keeps the rejection log readable and stops one leaking container from taking a second patient's sample with it.

Is a 95 kPa bag reused between patients?

No. The bag is secondary packaging and is discarded with the shipment. Reuse also destroys the seal the closing procedure depends on.

Do I count bags per patient or per test?

Count per accession, which is usually per container. A patient with a blood draw and a urine sample leaves the clinic as two bags, not one.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.