Ultrasonic Cleaner Brands Sold in Canada: Specifications, Models and Ordering

CliniEco CS6.2 six litre benchtop ultrasonic cleaner with lid and basket

A clinic buying an ultrasonic cleaner in Canada is usually choosing between two very different things: a brand it has heard of, and a specification it can actually check. The brand tells you who will answer the phone in three years. The specification tells you whether a cassette fits, whether the cycle can be repeated by whoever is on shift, and whether the record you write at the end of the day will survive an inspection.

This article separates those two questions. It lists the six benchtop models a Canadian clinic can order today, with the numbers that decide fit, and it sets them beside three brands that appear in Canadian dental distribution, quoting each manufacturer's own published figures. A 6 L unit is the size at which a full instrument cassette fits in one cycle, and it is the CS6.2 dual-frequency 6 L unit in this range; the 4 L, 7.5 L, 8 L and 20 L units below cover the other rooms a practice actually has.

Which ultrasonic cleaner models can a Canadian clinic order today?

Six benchtop models are stocked for Canadian delivery, and the range sits together in the ultrasonic cleaners collection. They are not variants of one machine: they differ in tank size, in inside dimensions, in frequency, in how temperature is set, and in what arrives in the box. The first table is the one to measure against a cassette; the second covers the operating details that decide whether the unit fits the workflow.

Model Tank capacity Inside dimensions (cm) Frequency
CS4.0 4 L (4,000 ml) Not stated in the supplied specification Dual — 32 / 48 kHz
CD-4862 6 L (6,000 ml) Tank opening 32.5 × 20.4 × 9.9 (accepts instruments up to 34 cm) 35 kHz
CS6.2 6 L class 31.1 × 17.2 × 11.6, SUS304 stainless Dual — 32 / 48 kHz
CD-4875 7.5 L nominal; 6,000 ml working volume Not stated in the supplied specification 35 kHz
CS8.0 8 L nominal; 7,000 ml working volume; 3,600 ml minimum fill Basket 31.15 × 21.15 × 5.5 49 kHz
CS20 20 L (5.3 US gal) Chamber 42 × 26 × 20 35 kHz
Model Temperature control Basket Drain List price (CAD)
CS4.0 Controlled heating, set-point shown in °C and °F; range not stated in the supplied specification Stainless basket available as an accessory Drain valve fitted $449.00
CD-4862 Five presets — 40 / 45 / 50 / 55 / 60 °C Basket available as an accessory Not stated in the supplied specification $649.00
CS6.2 40–60 °C selectable on two ceramic heaters; 120 s degas cycle SB01 stainless basket included Not stated in the supplied specification $699.00
CD-4875 Five presets — 40 / 45 / 50 / 55 / 60 °C Basket available as an accessory Drain valve fitted $849.00
CS8.0 Heater fitted; set-point range not stated in the supplied specification Basket available as an accessory Drain valve fitted $999.00
CS20 Heating fitted with electronic control; range not stated in the supplied specification Basket available as an accessory Electric drain valve $1,199.00

Several cells say "not stated", and that is deliberate: a specification sheet that omits the inside dimensions of a 4 L tank is telling you to ask before the order is signed, not inviting you to assume the missing number. Every figure above is taken from the product record as currently listed; prices are listed figures at the time of writing, so confirm them on the product page before raising a PO.

Why do nominal capacity and working volume not match?

Capacity is a marketing number derived from the shell; working volume is what you can actually fill and still load. The gap is not small: an 8 L tank holds 7,000 ml of working liquid with a 3,600 ml minimum fill, and a 7.5 L tank holds 6,000 ml — the same usable load as the 6 L class. Buying the larger shell in that pair buys headroom for longer trays and less splashing, not a second cassette.

The same distinction appears in manufacturer literature for other brands. The Coltene BioSonic UC150 is published as a 6.6 L tank with 5.7 L of usable capacity, and L&R publishes the SweepZone 310R at 12.3 L (3.25 gallons) — a recessed unit built to sit in a counter rather than on it.

Brand and model Published tank capacity Published working or fill volume Inside dimensions (cm)
CliniEco CS8.0 8 L nominal 7,000 ml working, 3,600 ml minimum fill Basket 31.15 × 21.15 × 5.5
CliniEco CD-4875 7.5 L nominal 6,000 ml working Not stated
Coltene BioSonic UC150 6.6 L (1.75 US gal) 5.7 L (1.5 US gal) Tank 28.7 × 16.0 × 17.8
L&R SweepZone 310R 12.3 L (3.25 US gal) Not stated 39.4 × 22.9 × 15.2
SharperTek XPD360-8L 8 L (2.1 US gal) Not stated 29.8 × 24.1 × 10.2

The practical rule: compare working volume when the question is "how many instruments", and compare inside dimensions when the question is "does my cassette fit". A tank can be large in litres and still be too shallow for a cassette that is 2 cm taller than the wall.

What does the frequency number change about the load?

Frequency sets the size of the bubbles the transducer creates, and bubble size sets what the tank is good at. Lower frequencies produce larger bubbles with more energy per collapse, which is what strips set cement and heavy soil; higher frequencies produce smaller, denser bubbles that reach into threads, box joints and hinged areas without the same impact on plated surfaces. That is why the dual-frequency units in this range carry 32 kHz and 48 kHz on one generator: 32 kHz for the heavier soil, 48 kHz for fine crevices, one unit covering the whole load.

The single-frequency units make a different trade. The CS8.0 runs 49 kHz only, chosen for small-bubble cavitation into threads and hinges; it will not strip heavy cement as quickly as a 32 kHz setting, and the honest answer for crown-and-bridge work with cement residue is to wipe the instrument before it goes in the tank rather than to extend the cycle. The CD-4862 and CD-4875 run 35 kHz, which sits between the two — closer in behaviour to the low-frequency end than to 49 kHz.

Other manufacturers publish comparable figures, so the number travels across brands even when the marketing language does not. L&R publishes 43 kHz ±2 kHz with an 83 Hz sweep rate on the SweepZone 310R — the sweep keeps moving the frequency so the cavitation field does not settle into a standing-wave pattern with dead spots. Coltene publishes the UC150 at 45–47.5 kHz, and SharperTek publishes the XPD360-8L at 40 kHz. None of these is better in the abstract; each is a choice about which soil the tank is built to remove.

Which brands are listed in Canadian dental channels?

Three brands appear in Canadian dental distribution with published specifications: L&R, Coltene and SharperTek. The table quotes manufacturer literature for each, and marks what the literature does not state rather than filling it in.

Brand and model Tank Inside dimensions (cm) Frequency Heat and drain as published Canadian channel checked
L&R SweepZone 310R 12.3 L (3.25 US gal) 39.4 × 22.9 × 15.2 43 kHz ±2 kHz, 83 Hz sweep Timer and drain standard; recessed unit Henry Schein Canada lists SweepZone 310 (AG910)
Coltene BioSonic UC150 6.6 L tank, 5.7 L fill 28.7 × 16.0 × 17.8 45–47.5 kHz Code 60021987 is listed without heat, drain fitted; heating is an optional code-activated feature Henry Schein Canada lists the UC150 unit
SharperTek XPD360-8L 8 L (2.1 US gal) 29.8 × 24.1 × 10.2 40 kHz Digital temperature-controlled heating, side drain pipe, two-year warranty No Canadian distributor listing verified; manufacturer page showed the model out of stock when checked

Three points about that table. First, these are specifications, not performance claims: none of the three publishes comparative cleaning-efficacy data against the others, and no independent comparison was found in the sources checked. Second, availability moves — the SharperTek reference is a US manufacturer page, so a Canadian buyer would need to confirm distribution, lead time and the mark on the unit itself. Third, a brand listed in a Canadian catalogue is sold through a distributor, so warranty and service route through that distributor rather than through CliniEco. We list these rows so a buyer can compare, not because we handle them.

Does a clinic need heat, a drain and a basket?

Heat is the specification most often ordered for the wrong reason. An enzyme solution has a temperature window on its label, and a tank that cannot hold that window under-performs on the same load no matter what the timer says. What matters for an audit is not the maximum temperature but whether the number you set is the number you can record: a five-preset ladder at 40, 45, 50, 55 and 60 °C gives a fixed set-point for the log, while a rotary thermostat gives a number that drifts with the hand that turned it.

A drain decides how the end of the shift feels. A drain valve on a 4 L or 8 L unit means the tank is emptied into a container or a sink without lifting it; the 20 L CS20 has an electric drain valve, which is the difference between a unit that gets changed on schedule and one that gets topped up because emptying it is a two-person job. Where the supplied specification does not state the drain arrangement — as with the CD-4862 and CS6.2 above — ask the supplier for the answer in writing before ordering, because it is not a detail you can retrofit comfortably.

Baskets are the quiet cost. The CS6.2 ships with the SB01 stainless basket included and the basket can be re-ordered on its own when it wears, so a replacement does not mean a new machine. On the other models the stainless basket is an accessory, and a clinic that adds it later pays the accessory price rather than the bundled one. Instruments also go in the basket, never flat on the tank floor: metal resting on metal blocks cavitation underneath the instrument and wears the stainless.

What electrical certification should be on the nameplate?

Canadian clinics are usually asked to show an electrical safety mark, not a cleaning certificate. The units in this range carry a cETL mark issued by Intertek, tested against UL 73 and CSA C22.2 No. 68, and the report number is the thing to quote when a technician or an inspector asks which certificate covers the unit: 220112139GZU-001 covers the CS4.0, CS8.0 and CD-4875; 210716104GZU-001 covers the CD-4862; 260210005GZU-001 covers the CS20. The CS6.2 is published as cETL by Intertek to the same two standards.

Read the mark precisely, because the assumption around it is usually wrong: an ETL mark from Intertek certifies electrical safety. It is not a UL listing, it is not CSA certification, and it says nothing about how well the tank cleans. CE, FCC and RoHS marks on low-cost imports are not electrical safety certifications either, and under the Ontario Electrical Safety Code a unit installed in a commercial setting is expected to carry a recognised certification mark.

What does an inspection look for that a specification sheet cannot answer?

Documentation. Ontario's provincial reprocessing guidance asks for "documentation and maintenance of records for each component of the cleaning, disinfection and/or sterilization process", based on the manufacturer's recommendations, and states that records "must be retained according to the facility's policy" (Public Health Ontario, provincial guidance on cleaning, disinfection and sterilization of medical equipment and devices in all health care settings, 3rd edition). No tank specification satisfies that requirement; a fill level, a set-point, a cycle length and a signature do, written the same way every day.

Canadian reprocessing practice sits on a separate standard, CSA Z314:23, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance. Health Canada's guidance on sterilization of reusable medical devices points the same way: the instrument manufacturer's instructions for use, not the cleaner's specification sheet, decide what happens to a given instrument after it comes out of the tank. An ultrasonic cycle lifts soil — cement residue, polishing paste, dried blood from hinges and threads — and it comes before pouching and the autoclave, never in place of it.

CliniEco CS6.2 six litre benchtop ultrasonic cleaner with lid and basket

What should be confirmed before signing a purchase order?

Five checks turn a brand decision into a specification decision. Each one has a place where the answer can be verified rather than remembered.

Check Why it decides the purchase Where to verify
Longest instrument you routinely clean A 4 L tank sets the length limit sooner than most buyers expect Measure the instrument; compare with the inside dimensions of the tank
Cassette dimensions, not cassette count A cassette that is 2 cm too tall does not fit any tank, whatever the litre figure says Measure the cassette; compare with inside dimensions and usable depth
Set-point range against the solution label An enzyme solution outside its temperature window under-performs on a correct cycle Solution label, then the unit's published temperature specification
Drain route and bench weight A 20 L tank is roughly 37 kg loaded on a 54 × 37 cm footprint Site visit before ordering; drain or container position
Certification mark and report number The mark that satisfies a technician is the cETL or equivalent, not CE or FCC Nameplate and the certificate report number, in writing

Clinics buying for several sites can also put the whole range on one line through wholesale and multi-site ordering, and the B2B wholesale collection lists the units stocked for institutional buyers. A purchase order that names the requirement — tank size, inside dimensions, frequency, temperature set-points, basket, drain, certification standard — survives a change of supplier. A purchase order that names only a brand transfers the decision to whoever answers the phone next year. Reselling? become a distributor.

CliniEco CD-4862 six litre ultrasonic cleaner with preset temperature display

Recording the cycles you already run? The compliance log centre carries a printable blank load sheet and a browser-based log generator that fill the date, solution and set-point rows for each station, and neither needs an account.

Have a question about your own reprocessing room? Send the tank size, the cassette and the solution you use, and you will get a written answer specific to your setup, with the standard or regulation it rests on cited. Ask your compliance question.

Related reading

Frequently Asked Questions

What is the difference between the CS6.2 and the CD-4862, both 6 L?

Same tank class, different machines. The CS6.2 puts 32 kHz and 48 kHz on one generator and includes the SB01 basket; the CD-4862 runs 35 kHz, fixes temperature in five presets from 40 to 60 °C, and has an opening of 32.5 × 20.4 × 9.9 cm that takes instruments up to 34 cm. If your protocol names a temperature, the preset ladder is easier to audit; if the soil varies across the load, the dual-frequency unit covers both ends.

Is 6 L enough to take a full instrument cassette?

Yes, and it is the size break the class is built around: a standard dental instrument cassette does not fit a 4 L tank and does fit a 6 L tank with inside dimensions of 31.1 × 17.2 × 11.6 cm. Below 6 L you are either unpacking instruments or running two cycles. Confirm with the cassette you actually use, because cassette designs vary.

Does a higher frequency clean better?

No — it cleans differently. Higher frequencies give smaller bubbles that reach threads, hinges and box joints and are gentler on plated surfaces; lower frequencies give larger bubbles with more energy per collapse, which is what strips set cement. That is why 32 kHz and 48 kHz sit on one generator rather than being two products.

Do I need a heated tank?

If your solution label specifies a working temperature, yes — an enzyme solution outside its window under-performs even on a correct cycle. The second question is how the temperature is set. A five-preset ladder at 40, 45, 50, 55 and 60 °C gives a fixed set-point that can be written into a log; a dial gives a number that depends on who turned it.

Is a CE or FCC mark enough for a clinic in Canada?

No. CE, FCC and RoHS are not electrical safety certifications. The units in this range carry a cETL mark from Intertek, tested against UL 73 and CSA C22.2 No. 68, and a unit installed in a commercial setting is expected to carry a recognised certification mark under the Ontario Electrical Safety Code. Ask for the report number, not the logo.

Can a benchtop ultrasonic cleaner sterilise instruments?

No. It cleans. The cycle lifts soil — cement residue, polishing paste, dried blood from hinges and threads — and that step comes before pouching and the autoclave, never in place of it. Public Health Ontario states the point directly: indicators and cleaning steps do not verify sterility, they allow detection of failures in the process that does.

Which model fits a two-chair practice?

The 8 L CS8.0, at 49 kHz, is the size built for two chairs' instruments in one cycle — the morning load runs once instead of twice. It is a single-frequency unit, so heavy cement is better handled by pre-wiping than by extending the cycle. A single-chair practice running loose instruments is served by the 4 L CS4.0; several chairs or batch work is the point at which the 20 L CS20 starts to pay for itself.

Are the brands in this article sold by CliniEco?

No. L&R, Coltene and SharperTek are listed here because they appear in Canadian dental distribution and publish specifications a buyer can check; they are not part of the CliniEco range and we do not supply them. CliniEco Medical is a Canadian distributor operating under Health Canada MDEL #35334, and the six models in the first two tables are the units we stock.

Specifications and prices are as published at the time of writing and can change; confirm them on the current product page before ordering. This article describes equipment selection and documentation practice for information and is not legal advice.

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.