Proving Impression-Disinfecting Competency at an Ontario Audiology Clinic Without a Training Binder

Aurelia Protégé nitrile exam gloves, 4.0 mil, 100 per box, the glove worn while disinfecting impression trays

Proving Impression-Disinfecting Competency at an Ontario Audiology Clinic Without a Training Binder

A clinician takes an ear impression, wipes the tray, notes the time and calls the next patient. Two years later a complaint reaches the college and somebody asks for proof that whoever did that wipe-down knew the contact time. There is no certificate on the wall and no course roster to hand over. In a small Ontario audiology clinic that is ordinary, and it is not a compliance failure — it is a documentation gap that closes with one page.

Why is there no training binder to produce?

Ontario's personal service settings regulation, O. Reg. 136/18, does set a disinfection record rule and a retention clock. It excludes, in s. 2 (2) (d), "a setting where the personal services are primarily provided by a member of a health profession set out in Schedule 1 to the Regulated Health Professions Act, 1991 who is engaged in the practice of his or her profession." Audiologists register under the Audiology and Speech-Language Pathology Act, 1991, a Schedule 1 statute, so the settings-based rule never attaches to their rooms. The college's records regulation governs the paper instead.

The clinic is not missing a form the province invented; it is missing its own written account. The consumables behind that account ride the ordinary supply order — CliniEco Medical Alcohol Prep Pads — 70% Isopropyl, 200 per Box, Aurelia PerOxy Disinfecting Wipes — 0.5% Hydrogen Peroxide, 160 per Pack and Aurelia Protégé Nitrile Exam Gloves — 4.0 mil, 100 per Box.

CliniEco Medical alcohol prep pads, 70% isopropyl, box of 200, laid out for wiping an ear impression tray

Which document replaces the certificate?

Nothing replaces it one for one. Four small documents do the same work, and three already exist in most clinics.

Evidence What it proves Where it lives
Manufacturer's instruction Contact time belongs to the maker Product file
One observed disinfection The task was done once, on this equipment Competency page
Log line: date, solution, concentration, contact time, initials Who did what, with which product Disinfection log
Policy naming two clinicians and a deputy The clinic decided who may do it Clinic manual

Aurelia Protégé nitrile exam gloves, 4.0 mil, 100 per box, the glove worn while disinfecting impression trays

What belongs on an impression log line?

The field list in O. Reg. 136/18 s. 14 (1) 2 works as a template even though it does not bind an audiology clinic: disinfectant name, concentration, the date the solution was prepared, the date it must be discarded. Add the case identifier, the material, the contact time used and two sets of initials.

Who signs when the regular clinician is away?

A named deputy, written into the policy before the absence. The record standard asks for entries that are complete, dated and signed, and a signature from someone never designated is what a reviewer cannot reconcile. Put the position beside the initials — audiologist, hearing instrument practitioner, clinical assistant — so the page answers who may as well as who did.

How long should the impression record stay in the file?

Ten years is the working figure: the college's records regulation sets a ten-year minimum for a patient's health record and for the equipment service record kept under s. 34. An impression line is equipment evidence, so it belongs with that record. Where the patient was under 18 at last contact, the clock runs from the day that patient turned 18.

See primary care clinic supplies for the consumables beside the impression bench. Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. Ontario Regulation 136/18, Personal Service Settings, s. 2 (2) (d) and s. 14 (checked 23 November 2026)
  2. Ontario Regulation 21/12 (General), Part II Records, s. 32 (6) and s. 34, made under the Audiology and Speech-Language Pathology Act, 1991 (records provisions as substituted by O. Reg. 164/15) (checked 23 November 2026)
  3. College of Audiologists and Speech-Language Pathologists of Ontario — Documentation Standards (checked 23 November 2026)

Printable companion: the equipment and maintenance log sheets print the same columns as an impression-disinfection entry — date, solution, contact time, initials — so the page matches the rest of the binder.

Want the columns already set out rather than a blank page? The clinic supply planner and log templates carry the room-by-room sheets, with the review dates built in.

Related Reading

Frequently Asked Questions

Is there a certificate that proves a clinician can disinfect an impression tray?

None is issued for the task. What a reviewer can read is the manufacturer's contact time, one disinfection performed under observation, and signed log lines that name the tray, the solution and the person.

Does Ontario's two-year record rule for personal service settings reach an audiology clinic?

No. Section 2 (2) (d) of O. Reg. 136/18 excludes settings where personal services are primarily provided by a Schedule 1 health profession, so the clinic follows its college's records regulation instead.

What if the clinic has never written a competency policy?

Write one page now and date it. Name who may disinfect impressions, name a deputy, and attach the manufacturer's contact time; entries made after that date are then checkable against a rule that existed when they were written.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.