Which MTC Bio 200 and 300 microlitre Pipette Tips, Sterile Racked, and Gel-Loading Tips Do Research Laboratories in Vancouver Order? Sizes and Case Formats

Standard and gel loading 200 microlitre pipette tips side by side

Which MTC Bio 200 and 300 microlitre Pipette Tips, Sterile Racked, and Gel-Loading Tips Do Research Laboratories in Vancouver Order? Sizes and Case Formats

A plate run starts before the pipette is picked up. It starts with the rack that is already open on the bench, and in a Vancouver research laboratory the question is rarely whether to use a 200 microlitre tip; it is which format of that tip belongs in the cupboard, because sterile racked tips are ordered by the case and this case does not hold a round thousand.

The MTC Bio 200 and 300 microlitre sterile racked pipette tips are packed 960 tips to a pack, ten racks of 96, and five packs to a case, which is 4,800 tips across 50 racks. The 0.7 mm gel-loading version is packed the same way, so a bench keeps one rack stand and changes only what sits in it.

What is in a case of 200 and 300 microlitre tips?

The arithmetic is the part that goes wrong on a purchase order. A buyer who is used to 1,000-tip cases from other lines budgets four cases for 4,800 tips and ends up with 19,200. Here the bench unit and the order unit are different things, and both belong on the stock record.

Format Racks Tips Opens as
Single rack 1 96 a refill for a stand
Pack 10 960 one sleeve, sealed
Case 50 4,800 five sealed sleeves

Racked sterile 200 and 300 microlitre pipette tips in a 96 position box

Fifty racks is also a storage figure rather than only a count: a shelf that takes one 96-position box takes the whole case, so the tip supply does not need a cupboard of its own.

When does a bench want the 0.7 mm gel-loading tip?

A gel-loading tip exists for one job. It passes between the glass plates of a polyacrylamide assembly and deposits the sample into a well without puncturing the gel, and a 0.7 mm orifice is what makes that possible.

The two are not interchangeable in either direction. A standard tip will not enter a 1 mm well cleanly, and a gel-loading tip is too narrow for routine liquid handling, so a laboratory that runs both a plate assay and a gel keeps the two racks on the same bench rather than choosing between them. Because the gel-loading pack follows the standard 960 and 4,800 counts, it is easy to hold without a second ordering rule. Where aerosol carry-over matters instead of gel loading, the filtered 200 and 300 microlitre tips put a barrier in the same rack footprint.

Standard and gel loading 200 microlitre pipette tips side by side

Which case format suits a laboratory that runs one plate a day?

One plate a day consumes about one rack a day at 96 wells, so a pack of ten racks covers ten working days and a case covers fifty, which is ten working weeks at a five-day week. A bench that runs two plates a day halves that, and the reorder point moves with it.

The practical check is the sleeve, not the case. When the last sealed sleeve is broken the bench has around two weeks of supply left at one plate a day, which is early enough to raise a purchase order without borrowing a rack from the next bench.

What decides whether a tip leaks, and what has to be recorded?

Seating depth decides it. A tip that sits too high on the shaft draws air at the start of the stroke, and one that sits too low pushes the pipette barrel toward the plate. The same fitment question decides whether a wide-bore 200 microlitre tip is the right substitute for a shear-sensitive sample. ISO 8655-2 treats the pipette and its tip as a measuring system rather than as separate parts, which is why one rack should be tested on the actual pipettor before a bench commits to a case, and why the pipette brand belongs in the procedure note rather than in a memory.

The record side is separate. Tips are consumables that leave the bench, and the Canadian Biosafety Standard handles that under decontamination and waste management, where a load is defined by amount, size or weight rather than by a count of items; verification is done on the kind of load that actually runs. A rack count on a stock card is an ordering figure, not a decontamination record, and the two should not be filed in the same place.

Running a research or diagnostic laboratory? See our laboratory consumables and specimen handling supplies, and the lab pipette tips collection lists the racked lines held in stock.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. Canadian Biosafety Standard, third edition — Public Health Agency of Canada (checked 26 November 2026)
  2. Medical Devices Regulations, SOR/98-282 (checked 26 November 2026)
  3. ISO 8655-2:2022, piston-operated volumetric apparatus, pipettes (checked 26 November 2026)
Printable companion: the lab log and record library prints a dated one-page sheet from the fields you type, so a rack that leaves the bench carries a line in the record. Sizing a standing order rather than a one-off? The clinic supply planner works through racks per bench per week before a case count is fixed.

Related Reading

Frequently Asked Questions

How many tips are in a case of MTC Bio 200 microlitre tips?

4,800. One pack is 960 tips in ten racks of 96, and a case holds five packs, so a case is 50 racks. The gel-loading configuration follows the same pack and case count.

Can a gel-loading tip replace the standard tip for routine work?

Not comfortably. A 0.7 mm orifice is built to pass between glass plates and deliver into a well without puncturing the gel; routine reagent transfer at 20 to 300 microlitres wants the standard orifice, so most benches keep both racks out.

When is a wide-bore tip the right choice instead of a standard 200 microlitre tip?

When the liquid resists the narrow bore: viscous reagents, glycerol mixes and cell suspensions shear or foam in a standard tip, and a wide-bore tip moves the same volume through a larger opening at a lower shear rate.

Can the standard and gel-loading tips share one rack stand?

Yes. Both configurations use the same rack footprint, so a bench swaps the rack rather than the hardware, and a case arrives as five sealed sleeves of ten racks so one sleeve can go to the bench without breaking the seal on the rest.