DLAB HB105-S1 dry bath incubator - 20-well block for 24-hour biological indicators, 56-60 C

Biological Indicator Incubator - DLAB HB105-S1 Dry Bath, 20-Well, 56-60 C, 24-Hour Readout

SKU DLAB-HB105-S1 · DLAB
$474.00
In stock · ships from Toronto, ON
Dry-block incubatortype
HB105-S1model
Room temperature +5 to 105 °Ctemperature range
±0.3 °C (25-90 °C); ±0.6 °C (90-105 °C)temperature accuracy
Pack sizeSingle configuration Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping across Canada — included

Specifications

TypeDry-block incubator
ModelHB105-S1
Temperature rangeRoom temperature +5 to 105 °C
Temperature accuracy±0.3 °C (25-90 °C); ±0.6 °C (90-105 °C)
Temperature uniformity±0.2 °C at 37 °C
Timer0 min to 99 h 59 min
Voltage115 V AC, 50/60 Hz

Pricing

OrderUnit price
1 unit$474.00 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 17 sections · specs, use, compliance

FOR STERILITY ASSURANCE PROGRAMMES

DLAB HB105-S1 Dry Bath Incubator with Lid — 20-Well, 24-Hour Biological Indicator Incubation

Laboratory-grade dry-block incubation, built for the audit rather than the brochure.

Holds self-contained biological indicators at 56–60 °C for the full 24-hour readout, with control accuracy of ±0.3 °C from 25 °C to 90 °C and ±0.6 °C from 90 °C to 105 °C, and no water bath to fill, change or contaminate.

Launch offer — 50 biological indicators included

Every incubator in this launch batch ships with 50 × 24-hour biological indicators (the 50-pack is listed at $109.99). At two indicators per sterilisation cycle that covers 25 cycles — enough to run a full spore-testing month while the machine is new.

  • 25–90 °C: ±0.3 °C, 90–105 °C: ±0.6 °C control accuracy; ±0.2 °C uniformity at 37 °C — the temperature stability a sterility assurance file depends on.
  • One block, 20 wells at 11 mm — sized for standard self-contained vials (8 mm body, 10 mm cap) to ISO 11138-3, not a general-purpose dry bath.
  • Supplied with a 20-well block for 8.8 mm tubes.
  • cTUVus certified — TÜV Rheinland certificate CU 72205506 0001, tested to UL 61010-1 and CAN/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B and ICES-001 registrations on file.
What an auditor asks What this unit answers
Was the indicator held at the required temperature for the whole readout? 56–60 °C held for 24 h, within ±0.3 °C, checked against an optional PT1000 reference probe.
Is the indicator itself traceable? Every BI lot ships with a certificate of analysis stating the measured spore population and D-value.
Can you produce the electrical safety documentation? cTUVus certificate number, standards tested to, and FCC/ICES registrations — supplied as documents, not as claims.
Where is the temperature record kept? On your own load sheet. The display holds temperature and time, and this unit does not log or export data — we would rather tell you that here than have you find it after delivery.

This is a dry-block incubator, not a reader and not a data logger. The result is read visually on the indicator — purple passes, yellow fails.

Model: DLAB HB105-S1 dry bath incubator with transparent lid

Capacity: one block, 20 wells (5 × 4), 11 mm well diameter

Temperature range: room temperature +5 °C to 105 °C, 0.1 °C display resolution

Accuracy: 25–90 °C: ±0.3 °C, 90–105 °C: ±0.6 °C; uniformity ±0.2 °C at 37 °C; PT1000 external probe supported

Timer: 0 min to 99 h 59 min

Weight: 3.2 kg with the block fitted

Note: this page previously covered the HB120-S (no lid). It now ships as the HB105-S1 with a transparent lid — same programme, same bundle, now 20 wells. Existing orders and links are unaffected.

🎁 Buy This Incubator — Get a Free 50-Pack of BIs

Order the incubator today and we'll include 50 spore tests (a $109.99 value) at no charge — start your daily monitoring from day one.

Add incubator + free 50-pack

This button puts both items in your cart — the 50-pack shows at $0 and you pay only for the incubator. If you prefer, add the 50-pack yourself: the discount applies automatically to one 50-pack per order.

DLAB HB105-S1 LED Dry Bath Incubator with Lid — for 24-hour biological indicator incubation

A dry-block incubator built for sterility assurance programmes: hold self-contained biological indicator vials at 56–60 °C for the 24-hour readout, with no water bath and no separate reader to buy.

  • Transparent lid for heat preservation — your vials sit in the block for a full 24 hours, and the lid keeps both the heat in and the dust out. The lid is closed by hand.
  • One heating block — 20 wells (5 rows × 4 columns), enough for a day of spore tests plus their controls in a single batch.
  • Temperature uniformity ±0.2 °C at 37 °C, control accuracy ±0.3 °C from 25 °C to 90 °C and ±0.6 °C from 90 °C to 105 °C. Runs from room temperature +5 °C up to 105 °C, with 0.1 °C display resolution.
  • Supports a PT1000 external sensor, so you can read from a reference point rather than the block.
  • Timer, 0 min to 99 h 59 min — set it and walk away.
  • cTUVus certified — cTUVus, TÜV Rheinland certificate CU 72205506 0001, tested to UL 61010-1 and CAN/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B (registration AK 50495998 0001) and ICES-001:2006 (registration AK 50496013 0001). 115 V AC, 50/60 Hz power supply (North American plug).
  • Overheating protection. Manufacturer: DLAB Scientific Co., Ltd., Beijing. Sold in Canada by CliniEco Medical, Health Canada establishment licence MDEL #35334.

For biological indicator incubation
Intended for steam-cycle biological indicators — Geobacillus stearothermophilus self-contained vials to ISO 11138-3 — incubated between 55 and 60 °C with a 24-hour readout. The 11 mm wells take vials with a body diameter of 8 mm and a cap diameter of 10 mm.

What this unit does, and does not, do
The result is read visually on the indicator itself: the medium stays purple when the cycle passes and turns yellow on a failure. This unit is an incubator, not a reader — it does not interpret fluorescent or rapid-readout indicators, which require a fluorescence reader. It does not record or export data; temperature and time are shown on the LED display and are kept on your daily record sheet.

What does spore testing cost per year with this incubator?

Item Price Cost per test
HB105-S1 dry bath incubator with lid (one-time) $499.00 —
24-hour self-contained biological indicator, 25-pack $69.99 $2.80
Daily monitoring on one sterilizer, 250 tests a year $699.90 in indicators $2.80

First-year total for a single sterilizer is $499.00 for the incubator plus $699.90 in indicators, or $1,198.90; with the launch offer at the top of this page the first 50 indicators are included at no charge, which brings the first-year figure to $1,088.91. From the second year the annual cost is the indicators alone. The 250-test line assumes one test on each day the sterilizer is used, five days a week; a site running two sterilizers doubles the indicator line.

Which biological indicators work in this incubator?

This is a dry bath held at 56 to 60 °C for the 24-hour readout, which is the incubation condition self-contained Geobacillus stearothermophilus indicators to ISO 11138-3 are designed for. The 11 mm wells take vials with a body diameter of 8 mm and a cap diameter of 10 mm. Rapid-readout indicators — 1-hour, 3-hour and 20-minute fluorescence — are not incubated here; they need their own reader.

How many indicators fit in one run, and is that enough?

Attribute Specification
Heating blocks One block, 20 wells (5 rows × 4 columns)
Well size 11 mm diameter, for 8 mm vial body / 10 mm cap
Temperature range Room temperature +5 °C to 105 °C
Control accuracy 25–90 °C: ±0.3 °C; 90–105 °C: ±0.6 °C
Uniformity ±0.2 °C at 37 °C
Timer 0 min to 99 h 59 min
External sensor PT1000 supported
Electrical AC 115 V, 50/60 Hz, North American plug
Lid Transparent, hand-closed — keeps heat in and dust out during the run
Certification cTUVus, TÜV Rheinland certificate CU 72205506 0001 (UL 61010-1, CAN/CSA-C22.2 No. 61010-1-12); FCC Part 15 Subpart B, registration AK 50495998 0001; ICES-001:2006, registration AK 50496013 0001

Twenty wells take twenty vials in one batch: ten spore tests, each paired with its matching control — the pattern daily monitoring follows on a single sterilizer. A 25-pack therefore runs as two batches, which is why the launch offer ships the 50-pack with this unit. That matters because a 24-hour readout means the block is occupied for the whole day: if the batch does not fit, the results split across two days.

Do I need a reader with this incubator?

No. A 24-hour colour-change indicator is read by eye — the medium stays purple when the cycle passes and turns yellow on a failure — and recorded on your daily log. A fluorescence reader is only needed for 1-hour, 3-hour and 20-minute rapid indicators, where the result is a machine reading. This unit does not record or export data; temperature and time are shown on the LED display and copied onto your record sheet — a printable daily log is available at the compliance log centre. For questions about which monitoring interval applies to your own sterilizers, send the question to a sterilization compliance specialist and you get a written answer that cites the standard behind it.

Documentation
English user manual included, French on request. Manufacturer warranty terms are available on request. Not for household use.

Choosing the right option for your clinic

Before you order, the decisions that actually change the result are well count, temperature band, calibration evidence, and what an incubator you cannot defend costs at audit. The full buyer's guide covers them step by step: How to Choose a Biological Indicator Incubator for a Canadian Clinic.

Related supplies for the same workflow

24-hour self-contained biological indicators

Related articles

How does a 24-hour incubation run actually work, hour by hour?

The run is shorter to describe than it is to get wrong. After the sterilization cycle, each indicator is activated according to the manufacturer's instructions for use, labelled so it can be matched to the sterilizer and the load, stood in the block, and left at incubation temperature for the full readout period. With a 24-hour self-contained indicator that means the block is occupied for a working day, the lid stays on, and the result is read the following day against the unexposed control that was incubated alongside it.

Stage What happens at the unit What is written down
Load Vials stand in the 20 wells (5 rows × 4 columns, Ø 11 mm), which take an 8 mm vial body with a 10 mm cap Date, sterilizer, cycle type and lot code against each position
Set the temperature The block is set into the 56–60 °C band for steam indicators; the display reads to 0.1 °C Set point, and whether a reference probe was used
Run The timer counts through the readout period — 0 min to 99 h 59 min on this unit — with the transparent lid closed by hand Start time
Read Purple means no growth and the load releases; yellow means spores survived Result, read time, and the control's result
On a fail The load goes back for re-sterilization and the sterilizer is re-tested before anything in it is released The fail itself, the corrective step and the re-test result

Two things about that sequence are worth stating plainly, because they are where an inspection usually lands. The lid is closed by hand and there is nothing that closes it for you, so a run started in a hurry with the lid left off is a run at the wrong temperature. And the block only holds, it does not read: the colour change on the vial is the result, and this unit is not a reader.

How many vials fit in one run, and when does a result slide to the next day?

Twenty wells hold twenty vials, and a monitoring day needs two vials per sterilizer — the test and its matching control. That is ten sterilizer-days per batch, which is exactly one sterilizer over ten test days, or two sterilizers over five. A 25-pack therefore takes two batches, because twenty vials fit and five are left over; that leftover is why the 50-pack is the size that ships with this unit rather than the 25.

Sterilizers tested per day Vials needed per day Days one 20-well batch covers What that means for ordering
1 2 10 test days A 25-pack runs as two batches; a 50-pack as five
2 4 5 test days One week of daily monitoring per batch
3 6 3 test days Plan the week around the block rather than the block around the week
4 and up 8 and up 2 test days or fewer Time to ask whether one block is the right equipment for the room

Why this matters more than it sounds: a 24-hour readout occupies the well for the whole period, so a batch that does not fit does not run late — it splits across two days, and the second day's results are a day behind. A room that tests two sterilizers daily should be loading the whole week's worth of work into one batch, not discovering on Thursday that the block has been full since Tuesday.

What does the certification cover, and what goes in the file?

The electrical documentation is the part of a benchtop incubator that auditors ask for and that most listings do not print. This unit carries cTUVus certification from TÜV Rheinland under certificate CU 72205506 0001, tested to UL 61010-1 and CAN/CSA-C22.2 No. 61010-1-12, with the EMC registrations below held on file.

Item Reference What it covers
Electrical safety certification cTUVus, TÜV Rheinland certificate CU 72205506 0001 UL 61010-1 and CAN/CSA-C22.2 No. 61010-1-12
EMC, United States FCC Part 15 Subpart B, registration AK 50495998 0001 Emissions compliance for the US market
EMC, Canada ICES-001:2006, registration AK 50496013 0001 Emissions compliance for the Canadian market
Supply 115 V AC, 50/60 Hz, North American plug The building supply the unit is rated for
Manufacturer DLAB Scientific Co., Ltd., Beijing Who built the unit and issues the manual
Importer CliniEco Medical, Health Canada MDEL #35334 Who is accountable for it in Canada

Ask for the certificate and the two registration numbers as documents, not as claims on a listing page — that is the whole point of printing the numbers. The instruction manual ships in English with the unit and in French on request, and the manufacturer's warranty terms are available on request.

How is the incubation temperature set, and how is it checked?

The block runs from room temperature +5 °C up to 105 °C, and steam biological indicators are incubated in the 56–60 °C band, so the set point is a band rather than a single number. The display reads to 0.1 °C and the timer runs to 99 h 59 min, which covers a 24-hour readout with room to spare. The unit also supports a PT1000 external probe, which is the useful part: it lets a practice read from a reference point in the block rather than trusting the set point alone.

What the unit does not do is record. There is no logging and no export — the numbers on the LED display are copied onto your own record sheet, which is why the printable logs at the compliance log centre are worth printing before the incubator arrives rather than after. A practice that wants a temperature trace has to keep one; this unit holds the temperature, it does not document it.

What this incubator is not

Four exclusions, each of which sends a buyer somewhere else, and it is quicker to say them here than to discover them after delivery. It is not a reader: 1-hour, 3-hour and 20-minute fluorescence indicators need their own reader and are not incubated here. It is not a data logger. It is not a water bath, so there is nothing to fill, change or spill, and nothing that grows in a tank between runs. And it is not a general-purpose dry bath — the block is drilled for standard self-contained vials to ISO 11138-3, not for tubes of arbitrary size.

The direct consequence of the first exclusion is the one to plan for: a practice that wants same-shift release needs a rapid-readout system, and a practice that tests daily and releases the next morning is the one this unit is built for.

Who this incubator suits, and who it does not

Setting Fits? Reason
Solo or small practice, one sterilizer, daily testing Yes Two vials a day occupies a tenth of the block; the 50-pack ships with the unit for exactly this rhythm
Practice with two sterilizers tested daily Yes Four vials a day, twenty wells, a week of work per batch
Multi-site group standardising across rooms Yes, one per room The unit is a small benchtop box; a shared incubator between rooms means carrying activated vials down a corridor
Clinic using rapid-readout fluorescence indicators No Those need a reader; this block does not interpret them
Clinic wanting an automated temperature record No No logging or export — the record is written by hand

Where it does fit, the first-year cost is one capital line and one consumable line: the incubator once, the indicators every time the box runs out. Spread across a daily-monitoring year the unit is the smaller of the two numbers, which is worth knowing before a practice decides to keep spore-testing by hand and ordering the box that actually documents it later.

Where should the incubator sit in the reprocessing room?

It is a benchtop box of 3.2 kg with the block fitted, and it runs from a standard 115 V AC outlet with a North American plug, so the siting question is about workflow rather than services. Put it where the indicators are activated and where the record is written. A block that lives at the far end of the room from the log sheet is a block whose results get copied down from memory at four o'clock, which is the failure mode a paper record is supposed to prevent.

Siting question What the unit needs Why
Bench space Room for the footprint plus the hand-closed lid to open and close The lid is operated by hand at the start and end of every run
Power 115 V AC, 50/60 Hz, North American plug The unit is supplied as the North American build
Where the log is kept Beside the block, not across the room Result, time and lot code are copied off the vials and the display at the end of the run
Where vials are activated The same bench, or the bench next to it Activated vials go straight into the block rather than travelling
Traffic Off the walkway between the sink and the autoclave An incubator is bumped once a month in a busy room, and a knocked block is a lost batch

There is nothing to plumb and nothing to drain, which is the practical advantage of a dry block over a water bath: a bench, a socket and a log sheet are the whole installation.

What to check on arrival

Check What good looks like
Model and nameplate HB105-S1 with the transparent lid, matching the certificate number quoted on this page
Block One block, 20 wells in 5 rows of 4, Ø 11 mm, seated squarely in the unit
Lid Closes by hand, sits flush, and does not foul the vial caps
First run Set the block into the 56–60 °C band and confirm the display holds it before the first real batch
Documents Manual in the carton, certificate and EMC registrations on request, importer details on the label

Common questions

What temperature do I incubate a biological indicator at?

Steam biological indicators are incubated in the 56-60 degrees C range. The HB105-S1 holds room temperature +5 °C to 105 °C, with a control accuracy of ±0.3 °C between 25 and 90 °C and ±0.6 °C above that, so the incubation temperature is set and held for the full 24-hour readout period.

Do I need a reader with this incubator?

No. Self-contained 24-hour biological indicators are read visually by colour change after incubation. A fluorescence reader is only needed if you use the 1-hour or 3-hour rapid-readout indicators.

Does this incubator record or export data?

No. It is a dry-block incubator: it holds the incubation temperature and does not log or export data. Sterilization records are kept on our free printable log sheets.

Will my existing self-contained BIs fit the block?

The block takes standard self-contained biological indicator ampoules. Tell us the brand and model you use and we will confirm the fit before you order.

Is this the 115 V AC North American build?

Yes. It is the 115 V AC, 50/60 Hz North American build and is cTUVus certified for Canada and the United States.

The earlier incubator is gone - what replaced it?

This model replaced it. The DLAB HB105-S1 with lid is the incubator we currently stock and ship; the earlier model is no longer available.

What is the warranty, and who services it in Canada?

Manufacturer warranty terms are available on request.

What are the key specifications?

A dry-block incubator built for sterility assurance programmes: hold self-contained biological indicator vials at 56–60 °C for the 24-hour readout, with no water bath and no separate reader to buy.