DLAB HB105-S1 Dry Bath Incubator with Lid for Hospital Sterile Processing Departments in Alberta: Sizes, Specs and What to Order

DLAB dry bath incubator with the heating block fitted and the transparent lid closed

DLAB HB105-S1 Dry Bath Incubator with Lid for Hospital Sterile Processing Departments in Alberta: Sizes, Specs and What to Order

What does a 20-well dry block give an Alberta department?

Well count is the first thing a department outgrows. A single sterilizer monitored daily needs one well per test plus a control, and a second sterilizer doubles that on the same morning. The DLAB HB105-S1 dry bath incubator runs a single heating block with 20 wells, so a 25-vial monitoring set is split across two loads: 20 wells in the first run, then five wells plus the control.

Which specifications decide the purchase?

Five numbers matter, and three of them are printed on the data plate. Temperature uniformity at the working setpoint, control accuracy across the range, the run range and the display resolution decide whether the unit can hold 56 to 60 °C honestly. The other two are the well diameter and the well depth, which decide whether your vials fit at all.

Specification HB105-S1 Why it matters
Wells 20 in a single block Two loads per 25-vial set, one control well
Block well size 11 mm diameter Takes 8 mm body, 10 mm cap vials
Uniformity ±0.2 °C at 37 °C Holds the incubation band
Control accuracy ±0.3 °C (25–90 °C), ±0.6 °C (90–105 °C) Setpoint trust across the range
Range Room +5 °C to 105 °C Covers 56–60 °C with margin
Lid Transparent, hand-closed Heat retention, dust exclusion
Certification cTUVus (CU 72205506 0001), tested to UL 61010-1 and CAN/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B:2019 (AK 50495998 0001); ICES-001:2006 (AK 50496013 0001) Approvals for the Canadian and US markets

Why do the lid and the sensor matter?

A dry block without a lid loses heat at the upper end of the wells, and the upper part of a vial sits cooler than the block. Over a 24-hour readout that difference is not academic: the vial has to be held inside 55 to 60 °C for the whole period, and the lid is what makes the upper part of the well behave like the lower.

The PT1000 probe answers the audit question rather than the operating question. A department can show the setpoint and the display; showing that the vial well was at temperature needs a reference measurement, and the probe is how that gets recorded on the daily log.

What should be on the order?

Product image, not a photograph: DLAB HB105-S1 dry bath incubator with transparent lid

Four lines: the incubator, the external probe, the spare block for the vial format you actually use, and the indicators. The blocks are the line most often missed, because the unit ships with its block fitted for one vial size and a department that changes indicator format later needs a second unit rather than a block swap.

Order the indicators against the same arithmetic as the incubator. One test per sterilizer per monitoring day, five days a week, is about 250 tests a year; a 24-hour self-contained biological indicator, 25 per pack covers five weeks on a single sterilizer, so two sterilizers consume roughly two packs a month.

The load side of the same purchase is usually ordered together, which is why departments add Class 4 dual-indicator sterilization pouches, 3.5 × 9 inch and the matching autoclave tape to the same requisition.

Where does an Alberta department place the order?

Departments, health authorities and clinic groups order on account. Wholesale and multi-site ordering covers case pricing and purchase-order billing, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

Equipping a reprocessing bench? Clinic consumables gathers the incubator, indicators and records that surround them.

Print the free sterilization log sheet for the temperature and result, run the sterilization self-check before an inspection, or ask a sterilization compliance specialist to review how the record is kept.

References

  1. ISO 11138-3 — biological indicators for moist heat sterilization (checked 18 October 2026)
  2. ISO 11140-1 — chemical indicators for sterilization processes (checked 18 October 2026)
  3. ISO 17665:2024 — moist heat sterilization of health care products (checked 4 November 2026; supersedes ISO 17665-1:2006, withdrawn 1 March 2024)

Related Reading

Frequently Asked Questions

How many wells does a sterile processing department need?

Enough for one monitoring batch plus a control, with room for a second sterilizer on the same morning. A 20-well unit carries a 25-vial set as two loads rather than one, which is why a department running several sterilizers plans the run order instead of buying a wider block it cannot fill.

Why does the unit need an external sensor?

The internal sensor reads the block, and the block is what you control. A PT1000 probe reads a reference point of your choosing, so you can show that the well holding the vial is at 56 to 60 °C rather than trusting the setpoint on the display.

Does the incubator interpret the result?

No. It holds the vials at temperature for the readout period, and the technician reads the colour change on the vial: purple stays purple on a pass, the medium turns yellow on a failure. Fluorescent rapid-readout formats need a separate reader.

What comes in the box?

The unit, the manual and the fitted blocks, with the electrical certification document. Indicators, the external probe and spare blocks are separate lines, and a department that forgets the probe has no way to document well temperature.