CliniEco CD-4875 ultrasonic cleaner - 7.5 L benchtop tank, dual frequency 32/48 kHz, stainless basket

CliniEco Dental Ultrasonic Cleaner — CD-4875, 7.5 L Benchtop with Heating

SKU CLI-ULTRA-CLEAN-CD4875 · CliniEco Medical
$604.00

Ships to Canada only

In stock · ships from Toronto, ON
7.5 L nominal (7,500 ml, 2.0 US gal) — 6,000 ml working volumetank capacity
35 kHzfrequency
380 W, AC 100–120 V, 60 Hz, North American plugpower
CLI-ULTRA-CLEAN-CD4875sku
Pack sizeSingle configuration Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping across Canada — included

Specifications

Tank capacity7.5 L nominal (7,500 ml, 2.0 US gal) — 6,000 ml working volume
Frequency35 kHz
Power380 W, AC 100–120 V, 60 Hz, North American plug
SKUCLI-ULTRA-CLEAN-CD4875
BrandCliniEco Medical
CategorySterilization & Cleaning Equipment
AvailabilityIn stock

Pricing

OrderUnit price
1 unit$604.00 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 9 sections · specs, use, compliance

Quick answer: 7.5 L nominal, 6,000 ml working volume, 35 kHz and 380 W, with the same five temperature presets as the 6 L unit — more room in the tank, the same size of usable load.

This is the awkward row in any ultrasonic range, and it is worth being precise about why. A 7.5 L tank (7,500 ml, or 2.0 US gallons) has a 6,000 ml working volume, which is the same usable load as the 6 L class. What the extra shell buys is headroom: longer trays fit, splashing stays inside the tank, and the unit does not have to be filled to its limit. It does not buy a second cassette.

Scope of use. This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The Health Canada guidance on reprocessing information is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.

What are the CD-4875 specifications?

Read the working volume row before the capacity row. Between 6 L and 7.5 L the nominal figure moves and the usable figure does not, which is exactly the sort of detail that decides a purchase.

Tank capacity: 7.5 L nominal (7,500 ml, 2.0 US gal) — 6,000 ml working volume

Frequency: 35 kHz

Power: 380 W, AC 100–120 V, 60 Hz, North American plug

Timer: 1 to 30 minutes

Heating: Five presets: 40 / 45 / 50 / 55 / 60 °C

Safety features: Dual heating protection, moisture-resistant PCB, detachable power cord

CD-4875 — 7.5 L benchtop ultrasonic cleaner, specifications as supplied
Field Specification
Tank capacity 7.5 L nominal (7,500 ml, 2.0 US gal) — 6,000 ml working volume
Tank dimensions 33.1 × 23.8 × 10.5 cm (length × width × depth), SUS304 stainless steel tank
Frequency 35 kHz
Power 380 W, AC 100–120 V, 60 Hz, North American plug
Timer 1 to 30 minutes
Heating Five presets: 40 / 45 / 50 / 55 / 60 °C
Safety features Dual heating protection, moisture-resistant PCB, detachable power cord
Drain Drain valve fitted
Electrical certification cETL — Intertek report 220112139GZU-001, to UL 73 and CSA C22.2 No. 68
Included Unit, one-year manufacturer warranty; stainless basket available as an accessory
List price CAD $849.00

Does this unit log cleaning cycles?

No. The CD-4875 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.

What the CD-4875 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.

Five fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.

Which tank size in the range fits your room?

If a cassette is the unit of work in your practice, the choice is 6 L or 20 L, and this size sits between them for a different reason: it gives the same 6,000 ml working load with more freeboard in the tank.

Model range as listed — tank, frequency and the load each size is built for
Model Tank Frequency Built for List price (CAD)
CS4.0 4 L 32 / 48 kHz Single chair, loose instruments $449.00
CD-4862 6 L 35 kHz Full cassette, five temperature presets $649.00
CS6.2 6 L 32 / 48 kHz Full cassette, dual frequency $699.00
CD-4875 7.5 L 35 kHz Larger trays, five temperature presets $849.00
CS8.0 8 L 49 kHz Two chairs into one cycle $999.00
CS20 20 L 35 kHz Several chairs or batch work $1,199.00

The practical case for this size is a bench where trays rather than cassettes are loaded — implant trays, orthodontic pliers laid out in a line, a row of handpieces that do not fit a cassette. Measure the tray first; if it fits with 2 cm to spare, this is the tank that stops the splashing.

Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed

How do you run a repeatable cleaning cycle on the CD-4875?

With more freeboard than the 6 L unit, this tank tolerates a tray that sits proud of the liquid line better than a brim-full smaller tank — but not a tray that is only half submerged. Load, then check the level.

Cycle set-up step by step
Step Setting Why it matters
1. Fill To 6,000 ml working volume with solution at the label dilution The 7.5 L figure is the shell, not the dose
2. Preset 40, 45, 50, 55 or 60 °C — matched to the solution label Enzymes have a working window; the preset keeps you inside it
3. Load Tray or basket, items separated, hollow instruments flooded Trapped air is the most common reason a lumen does not clean
4. Time 1 to 30 minutes, set to the interval your protocol names A number on the log, not an approximation
5. Drain, dry, record Empty through the valve, dry the chamber, log the cycle The record is the deliverable an inspection asks for

Because the usable volume is 6,000 ml whatever the shell says, the dose of solution is the same as a 6 L unit. Buying the larger tank does not mean buying more concentrate per cycle, and a log that records a larger dose than the label ratio is the kind of small inconsistency an auditor notices.

What an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for documentation and maintenance of records for each component of the cleaning, disinfection and/or sterilization process, based on the manufacturer’s recommendations, and repeats that records must be retained according to the facility’s policy (Public Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.

What does the cETL mark cover, and what does it not?

The CD-4875 is covered by Intertek report 220112139GZU-001 — the same report family as the CS units — rather than the 210716104GZU-001 report that covers the 6 L CD-4862. The mark on the unit is an ETL mark issued by Intertek, tested against UL 73 and CSA C22.2 No. 68. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, CSA Z314:23, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.

What the electrical certificate covers, and what it does not
Covers Does not cover
Electrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68 Cleaning performance on your instruments, on your water hardness, or at your solution concentration
The specific unit family named on Intertek report 220112139GZU-001 The condition of an individual unit after a drop, a repair, or a modification
Compliance of the supply, plug and cord assembly for the North American market Any clinical outcome, or any claim that the unit removes or inactivates micro-organisms
The identity of the certificate holder and the factory it was issued to Your own reprocessing records, which are yours to keep and produce

What is in the box, and what should be ordered with it?

One cleaner, 7.5 L, 110 V with a North American plug and the manufacturer warranty. Basket as an accessory. The detachable cord and the drain valve are the two features that make end-of-day cleaning quick.

Multi-enzyme ultrasonic cleaning solution is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The 6 L CS6.2 is the unit to look at if your load grows into full cassettes. Read how to choose a tank size and what to record on the cleaning log before you commit to a size.

What does one tank fill cost in cleaning solution?

The 7.5 L unit sits between the cassette tank and the 8 L bench unit, and the difference shows up in the fill arithmetic: roughly 19 mL of concentrate per full tank at 1:400, and just over fifty fills from a 1 L bottle. Clinics that run longer trays and change the bath once a day will see a pail pay for itself in handling time long before it pays for itself in chemistry.

CD-4875 — concentrate per full tank and pack yield at the two label dilutions
Dilution on the label Concentrate per full tank (7.5 L nominal capacity) Fills from a 1 L bottle Fills from a 5 L pail
1:400 — heavier soil ≈ 18.8 mL 53 fills 266 fills
1:600 — light soil ≈ 12.5 mL 80 fills 400 fills

Cost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 53 fills is roughly 11 working weeks from one bottle.

Which cleaning solution goes in this tank, and when should it be changed?

The tank is dosed with the multi-enzyme ultrasonic cleaning concentrate, packed as 1 L or 5 L, diluted 1:400 to 1:600 in water. Low-foam formulation, working temperature 20–50 °C, cycle 2 to 10 minutes, 24 months sealed shelf life and 90 days after opening — all of it printed on the label that comes with the pack.

The cleaner does not decide when the bath is spent; the label and your protocol do. What this unit adds is a drain valve, so the bath is emptied through the valve instead of being lifted out, and the change goes into the record in the same minute. Ontario guidance asks for documentation and maintenance of records for each component of the cleaning, disinfection and/or sterilization process, retained according to the facility’s policy (Public Health Ontario, 3rd edition, checked 2026-11-07).

What is the lead time, and what maintenance does the unit need?

This unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.

CD-4875 — routine maintenance and why each item is on the list
Task Interval Why it matters
Drain and refill At the interval the solution label and your protocol set Soil load accumulates in the bath whatever the instruments look like when they come out
Run a fresh fill before the first load Every refill Dissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in
Rinse tank and basket Every change Residue left on stainless carries soil into the next fill and films the tank over time
Wipe lid and check cord, plug and drain valve Weekly The three parts a drop or a wipe-down damages first
Keep the level above the working minimum Every cycle Running dry is the one failure mode that ends a tank’s service life early

Longer trays mean more shielding between instruments, so load discipline matters as much as chemistry: joints open, instruments not stacked, and the tray not resting directly on the tank floor where the transducer field is strongest and least even.

Related reading

CliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our sterilization desk.

Built to order. Allow 3–4 weeks — we confirm the dispatch date before the unit ships.

Common questions

What does the 7.5 L nominal, 6,000 ml working volume actually mean?

The 7,500 ml is the tank shell; 6,000 ml is the usable liquid when a loaded tray or basket is in place. Practically, this unit carries the same load as a 6 L tank, with more freeboard so a loaded tray is less likely to spill or sit proud of the liquid.

How many gallons is the 7.5 L tank?

2.0 US gallons nominal. If a supplier or a colleague quotes the tank in gallons, check whether they mean the shell or the working volume before comparing it with another unit.

What timer and temperature range does it have?

A 1 to 30 minute timer across the full range, and five heating presets at 40, 45, 50, 55 and 60 °C. Both are fixed numbers, which is what makes the cycle recordable.

Is the wire basket included?

No, it is an accessory on this model. Order it with the unit: instruments laid directly on the stainless floor wear the tank and block cavitation underneath them.

Would this unit take two cassettes in one cycle?

No. The working volume is 6,000 ml, which is a single-cassette load in this class. Two cassettes at once is 20 L tank territory, where the chamber is 42 × 26 × 20 cm.