CliniEco CS8.0 ultrasonic cleaner - 8 L nominal, 7,000 ml working volume, 49 kHz and 450 W with heater

CliniEco Dental Ultrasonic Cleaner — 8 L Benchtop, CS8.0 49 kHz with Heater

SKU CLI-ULTRA-CLEAN-80 · CliniEco Medical
$711.00

Ships to Canada only

In stock · ships from Toronto, ON
8 L nominal (8,000 ml) — 7,000 ml working volume, 3,600 ml minimum filltank capacity
49 kHz, single frequencyfrequency
450 Wpower
CLI-ULTRA-CLEAN-80sku
Pack sizeSingle configuration Single configuration
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping across Canada — included

Specifications

Tank capacity8 L nominal (8,000 ml) — 7,000 ml working volume, 3,600 ml minimum fill
Frequency49 kHz, single frequency
Power450 W
SKUCLI-ULTRA-CLEAN-80
BrandCliniEco Medical
CategorySterilization & Cleaning Equipment
AvailabilityIn stock

Pricing

OrderUnit price
1 unit$711.00 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 9 sections · specs, use, compliance

Quick answer: 8 L nominal, 7,000 ml of usable working volume, single frequency at 49 kHz — the size that takes two chairs' instruments in one cycle and the frequency that is easiest on hinged and plated instruments.

Two chairs into one cycle is the argument for an 8 L tank. The morning load runs once instead of twice, and the person doing it is not standing over a tank at 9:15 with patients already seated. The CS8.0 is also the only single-frequency unit in this range: 49 kHz, chosen for small-bubble cavitation into threads and hinges rather than for stripping heavy cement. If most of your soil is heavy, the dual-frequency 6 L is the better fit.

Scope of use. This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The Health Canada guidance on reprocessing information is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.

What are the CS8.0 specifications?

The distinction that matters most here is nominal against working volume. An 8 L tank is not 8,000 ml of usable liquid, and the working figure is what decides how many instruments go in.

Tank capacity: 8 L nominal (8,000 ml) — 7,000 ml working volume, 3,600 ml minimum fill

Frequency: 49 kHz, single frequency

Power: 450 W

Supply: AC 100–120 V, 60 Hz, North American plug

Drain: Drain valve fitted for emptying between sessions

Basket: Stainless basket available as an accessory; internal basket dimensions 31.15 × 21.15 × 5.5 cm

CS8.0 — 8 L benchtop ultrasonic cleaner, specifications as supplied
Field Specification
Tank capacity 8 L nominal (8,000 ml) — 7,000 ml working volume, 3,600 ml minimum fill
Tank dimensions 33.1 × 23.8 × 11.6 cm (length × width × depth), SUS304 stainless steel tank
Frequency 49 kHz, single frequency
Power 450 W
Supply AC 100–120 V, 60 Hz, North American plug
Drain Drain valve fitted for emptying between sessions
Basket Stainless basket available as an accessory; internal basket dimensions 31.15 × 21.15 × 5.5 cm
Electrical certification cETL — Intertek report 220112139GZU-001, to UL 73 and CSA C22.2 No. 68
Included Unit, one-year manufacturer warranty, Canadian warranty support from our Toronto warehouse
List price CAD $999.00

Does this unit log cleaning cycles?

No. The CS8.0 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.

What the CS8.0 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.

Five fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.

Which tank size in the range fits your room?

At this size the decision is usually between the 8 L and the 6 L: same family, similar footprint, different frequency and different usable volume. The 6 L is the cassette-size unit; the 8 L is the unit for two chairs' loads or for anyone who wants 49 kHz.

Model range as listed — tank, frequency and the load each size is built for
Model Tank Frequency Built for List price (CAD)
CS4.0 4 L 32 / 48 kHz Single chair, loose instruments $449.00
CD-4862 6 L 35 kHz Full cassette, five temperature presets $649.00
CS6.2 6 L 32 / 48 kHz Full cassette, dual frequency $699.00
CD-4875 7.5 L 35 kHz Larger trays, five temperature presets $849.00
CS8.0 8 L 49 kHz Two chairs into one cycle $999.00
CS20 20 L 35 kHz Several chairs or batch work $1,199.00

If you run more than eight or ten loads a day, neither of these is the answer — that is the point at which a 20 L tank with eight transducers starts to pay for itself. Below that threshold the 8 L removes the second run without turning the bench into a wet room.

Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed

How do you run a repeatable cleaning cycle on the CS8.0?

The 49 kHz setting is quieter and less aggressive than a 32 kHz tank, which changes how you load it rather than how long you run it. Fewer, better-spaced instruments clean better than a packed basket.

Cycle set-up step by step
Step Setting Why it matters
1. Fill 7,000 ml working volume — not the 8,000 ml the tank is named for Over-filling to the brim leaves no room for displacement and spills at the seam
2. Heat Bring the solution to the temperature printed on the solution label Enzyme activity has a temperature window; a cold tank under-performs on the same load
3. Load Basket only, instruments not touching each other Cavitation is blocked where two surfaces meet
4. Run One full cycle per load, timed from the panel A repeatable interval is what makes the log meaningful
5. Drain, dry, record Empty through the valve, dry the chamber, write the entry The record is what an inspection reads

Because 49 kHz works with smaller bubbles, it reaches into threads and box joints that larger bubbles miss, but it also gives up some stripping power on set cement. If you routinely clean crown-and-bridge work with cement residue, pre-wipe the instrument before it goes in the tank rather than extending the cycle.

What an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for documentation and maintenance of records for each component of the cleaning, disinfection and/or sterilization process, based on the manufacturer’s recommendations, and repeats that records must be retained according to the facility’s policy (Public Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.

What does the cETL mark cover, and what does it not?

The CS8.0 carries a cETL mark from Intertek under report 220112139GZU-001, the same report that covers the 4 L unit. The mark on the unit is an ETL mark issued by Intertek, tested against UL 73 and CSA C22.2 No. 68. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, CSA Z314:23, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.

What the electrical certificate covers, and what it does not
Covers Does not cover
Electrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68 Cleaning performance on your instruments, on your water hardness, or at your solution concentration
The specific unit family named on Intertek report 220112139GZU-001 The condition of an individual unit after a drop, a repair, or a modification
Compliance of the supply, plug and cord assembly for the North American market Any clinical outcome, or any claim that the unit removes or inactivates micro-organisms
The identity of the certificate holder and the factory it was issued to Your own reprocessing records, which are yours to keep and produce

What is in the box, and what should be ordered with it?

One cleaner, 8 L, 110 V with a North American plug and the manufacturer warranty. The stainless basket is an accessory, so ask for it explicitly if you want it shipped in the same box. No plumbing or drain pump is required.

Multi-enzyme ultrasonic cleaning solution is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The 6 L CS6.2 is the unit to look at if your load grows into full cassettes. Read how to choose a tank size and what to record on the cleaning log before you commit to a size.

What does one tank fill cost in cleaning solution?

An 8 L bath is usually bought for two chairs feeding one cycle, and that doubles the chemistry per fill against the 4 L unit while halving the number of fills a bottle gives. The arithmetic below uses this page’s own nominal capacity, so the millilitres are the ones your staff will actually measure at the bench.

CS8.0 — concentrate per full tank and pack yield at the two label dilutions
Dilution on the label Concentrate per full tank (8 L nominal capacity) Fills from a 1 L bottle Fills from a 5 L pail
1:400 — heavier soil ≈ 20 mL 50 fills 250 fills
1:600 — light soil ≈ 13.3 mL 75 fills 375 fills

Cost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 50 fills is roughly 10 working weeks from one bottle.

Which cleaning solution goes in this tank, and when should it be changed?

The tank takes the multi-enzyme ultrasonic cleaning concentrate in 1 L bottles or 5 L pails, diluted 1:400 to 1:600. Low-foam matters more as the tank gets bigger: the larger the free surface, the more foam a foaming product would build, and foam is cavitation energy that never reaches the instruments. Working window on the label is 20–50 °C over 2 to 10 minutes; sealed shelf life is 24 months, 90 days after opening.

How often the bath is changed belongs to the solution label and your facility protocol. The drain valve on this unit is what makes that a short job: empty, rinse, refill, and write the date on the log in the same line as the temperature and the operator. That record is what an inspection reconstructs the step from — Ontario guidance asks for documentation and maintenance of records for each component of the cleaning, disinfection and/or sterilization process, retained according to the facility’s policy (Public Health Ontario, 3rd edition, checked 2026-11-07).

What is the lead time, and what maintenance does the unit need?

This unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.

CS8.0 — routine maintenance and why each item is on the list
Task Interval Why it matters
Drain and refill At the interval the solution label and your protocol set Soil load accumulates in the bath whatever the instruments look like when they come out
Run a fresh fill before the first load Every refill Dissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in
Rinse tank and basket Every change Residue left on stainless carries soil into the next fill and films the tank over time
Wipe lid and check cord, plug and drain valve Weekly The three parts a drop or a wipe-down damages first
Keep the level above the working minimum Every cycle Running dry is the one failure mode that ends a tank’s service life early

Fill to the marked working volume rather than to the rim: the 8 L tank has a 7,000 ml working volume and a 3,600 ml minimum fill, and running near the minimum shortens the bath’s useful life in a busy room because the soil load builds faster.

Related reading

CliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our sterilization desk.

Built to order. Allow 3–4 weeks — we confirm the dispatch date before the unit ships.

Common questions

What is the real working volume of the 8 L tank?

7,000 ml of usable liquid, with a 3,600 ml minimum fill. The 8,000 ml figure is the nominal tank size; filling it to the brim removes the freeboard that keeps liquid off the housing seam when instruments go in.

Why is this unit 49 kHz when the 6 L unit is dual frequency?

49 kHz produces smaller bubbles, which is what you want for threads, hinges and fine tips. It is a single-frequency choice rather than an omission: the trade-off is less stripping power on heavy set cement, which is why the 6 L dual-frequency unit exists next to it.

Will 49 kHz damage hinged or plated instruments?

Frequency alone does not determine damage; the instrument manufacturer's instructions for use decide whether a given instrument may go into an ultrasonic bath at all, and at what temperature. Follow that document first, then set the tank.

Is 8 L enough for a two-chair practice?

For two chairs' hand instruments in one morning cycle, yes. If both chairs also produce full cassettes, the cassettes are the load that decides the tank, and a cassette-size unit or a 20 L tank is the more honest answer.

Is the basket included with the 8 L unit?

It is an accessory on this model rather than a line item, so request it on the order. Running instruments loose on the tank floor shortens their life and shadows the cavitation field.