Aurelia Protégé Nitrile Exam Gloves — 4.0 mil, Medical Grade, Sky Blue, 1,000 Gloves per Case (10 × 100)
Ships to the US · US$9.99 flat, free over $300
Specifications
| Thickness | 4.0 mil |
|---|---|
| Material | Nitrile, powder-free, latex-free, micro-textured |
| Box | 100 gloves |
| SKU | AUR-NG-PROT-40-S |
| Brand | Supermax Healthcare Canada (Aurelia) |
| Category | Hand Protection |
| Availability | In stock |
Pricing
| Order | Unit price |
|---|---|
| 1 unit | $75.04 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 10 sections · specs, use, compliance
These are Aurelia Protégé nitrile examination gloves at 4.0 mil, powder-free and latex-free, in sky blue, sold 1,000 gloves to a case as ten dispenser boxes of 100, and the middle-weight film is described by the manufacturer as micro-textured with the listing recording the glove as chemotherapy-tested.

What does 4.0 mil mean, and what is it measured against?
Mil is a thousandth of an inch, and glove thickness is quoted as a single-wall measurement at the palm rather than as an average across the glove. A 4.0 mil nitrile film sits between the thin 3.2 mil examination film used where feel matters and the heavier 4.5 to 6 mil films used for longer wear and rougher handling. Thickness is a handling property, not the barrier property: the barrier claim rests on the watertightness test and on the material specification, which for nitrile examination gloves is ASTM D6319.
ASTM D6319 sets minimum physical requirements for nitrile examination gloves, including tensile strength of at least 14 MPa and elongation at break of at least 500% before aging, together with a watertightness test used to detect pinholes. That matters because the failure that causes a clinic problem is not a glove that tears visibly — it is a glove with a pinhole that the wearer never notices.

What does the specification sheet on a 4.0 mil glove say?
The specification sheet for a glove is short, and every line on it is a purchasing decision: thickness sets handling, the standard sets the barrier test, the size list sets how many cases a team needs, and the packing sets storage and the reorder point.
| Specification | Detail |
|---|---|
| Material | Nitrile, powder-free, latex-free |
| Film thickness | 4.0 mil (single wall) |
| Surface | Micro-textured |
| Colour | Sky blue |
| Grade | Medical grade examination glove; the listing records chemotherapy testing |
| Sizes | S, M, L, XL |
| Box | 100 gloves |
| Case | 10 boxes — 1,000 gloves; about 5.3 kg |
How do 3.2, 4.0 and 4.5 mil gloves differ in practice?
The three weights in this range are not three grades of the same glove; they are three answers to the question "what does the task need from the film". Thin film transmits touch and is chosen where the clinician works by feel; thicker film resists snagging and holds up over longer wear. The table below is the one to keep at the ordering desk, because most over-ordering in this category comes from buying the heaviest film for every task.
| Film | What it gives you | Where it fits | Where it does not |
|---|---|---|---|
| 3.2 mil (Transform 100) | Tactile feel, fast donning, lower material use for each glove | High-volume examination, hygiene checks, short encounters | Long wet procedures, rough handling, extended wear |
| 4.0 mil (Protégé) | Balance of feel and durability, micro-textured palm | General examination, restorative dentistry, specimen handling, chemotherapy-tested tasks | Heavy chemical immersion, tasks needing maximum abrasion resistance |
| 4.5 mil (Robust) | Heavier film, fully textured for wet and dry grip | Long appointments, wet work, maintenance and cleanup | Fine tactile work where feel decides the outcome |
Is a 4.0 mil glove thick enough for chemotherapy handling?
Thickness alone does not answer that question, and it is worth being precise. Resistance to chemotherapy drug permeation is assessed by a specific practice, ASTM D6978, which measures how quickly a drug passes through the glove material rather than how thick the film is. Two gloves of the same thickness from different manufacturers can behave differently, because permeation depends on the polymer formulation, not on the calliper. This listing records the glove as chemotherapy-tested, which is the statement to match against the drug list your facility actually handles.
The published permeation literature makes two further points that a purchaser should carry into the decision. First, permeation rises with temperature and with applied force, so a glove tested on a bench does not behave identically on a warm hand under pressure. Second, double gloving has been shown to extend resistance for short periods, which is why chemotherapy protocols frequently specify two pairs rather than a thicker single pair.
Why do clinics report glove failures that the specification does not predict?
Because the specification tests new gloves, and clinics use worn ones. A prospective study that collected 1,500 consecutively used pairs of examination gloves on two intensive care units found micro-perforations in 10.3% of them using a water-tightness test, with significant differences in durability between brands that could not be predicted from the manufacturers' technical data. Only 26% of the pairs had been worn longer than 15 minutes, and the authors suggested changing gloves after about 15 minutes as a workable compromise between practicality and safety.
A laboratory study reached a compatible conclusion from the other direction: when 30 nitrile examination glove products were tested out of the box and again after two hours of simulated whole-glove movement, movement changed the leak results, and some products that passed when new did not pass after use. The practical translation for a clinic is that glove change discipline is a control in its own right. The US Bloodborne Pathogens standard says the same thing in regulatory language: disposable gloves are to be replaced as soon as practical when contaminated, torn, cut or punctured, or when their ability to function as a barrier is compromised.
How many gloves does a case actually cover?
A case holds 1,000 gloves, which is 500 pairs, and a pair is not the same as a patient encounter: gloves are changed when contaminated, when moving from a dirty task to a clean one, and when torn. The table below uses two gloves per encounter as the baseline and adds a change allowance, which is how most clinics actually consume them.
| Setting | Encounters per day | Gloves per day at 2 per encounter | Gloves per 21-day month | Cases at 1,000 |
|---|---|---|---|---|
| One clinician, 12 encounters | 12 | 24 | 504 | 0.50 |
| Two clinicians, 20 encounters | 20 | 40 | 840 | 0.84 |
| Two chairs, mixed procedures | 26 | 52 | 1,092 | 1.09 |
| Three chairs, full day | 36 | 72 | 1,512 | 1.51 |
| LTC unit, eight staff on rounds | 40 | 80 | 1,680 | 1.68 |
Two adjustments move that number materially. A clinic that changes gloves between every task within an encounter, as chemotherapy and specimen handling protocols often require, should add 50% or more. A unit that also uses gloves for cleaning and disinfection will consume several cases a month; those tasks belong to a utility glove, not to an examination glove, and mixing the two is the most common cause of an unexplained shortage.
What do buyers get wrong about glove sizing and case packing?
A case carries a single size. That is the detail that turns a purchase order into a problem in a practice where the team is spread across S to XL: a case of M gloves does not cover an L wearer, and splitting sizes means splitting cases. Sizing is worth doing once, properly, by having each clinician try the size they normally wear in this film — a 4.0 mil glove feels different from a 3.2 mil glove in the same nominal size. The case of ten dispenser boxes also determines storage: ten boxes take a shelf, and the dispenser opening is designed to be pulled one glove at a time, which reduces the contamination that comes from digging into an open box.
What should a US buyer confirm before reordering?
Confirm the regulatory status first, because this is the point where glove purchasing most often goes wrong. In the United States a non-powdered patient examination glove is a Class I device under 21 CFR 880.6250, and Class I is frequently misread as exempt: under that section only a finger cot is exempt from premarket notification, so a nitrile examination glove is expected to trace to a 510(k)-cleared device. Ask for the clearance reference and keep it with the purchase record.
Confirm the standard and the report behind it. The listing's material and performance claims rest on ASTM D6319 for the glove, and on ASTM D6978 where a chemotherapy claim is made. Confirm the case configuration of ten boxes of 100, and confirm the size split your team needs. Freight and duties for United States addresses are shown at checkout. For a multi-site group or a long-term-care contract, the institutional account enquiry is the route to a written quotation with the sizes and delivery addresses confirmed.
Sources, checked 2026-11-21
- ASTM D6319-19 — Standard Specification for Nitrile Examination Gloves for Medical Application
- ASTM D6978-05(2019) — Resistance of Medical Gloves to Permeation by Chemotherapy Drugs
- 21 CFR 880.6250 — Non-powdered patient examination glove (Class I; finger cot exemption)
- 29 CFR 1910.1030(d)(3)(ix) — Gloves: when required, when replaced
- OSHA Bloodborne Pathogens standard, 1910.1030
- Durability of examination gloves used on intensive care units (BMC Infect Dis, 2013)
- Integrity of disposable nitrile exam gloves exposed to simulated movement (2011)
- Glove permeation of chemicals: state of the art, part 2 (2020)
- Fentanyl and carfentanil permeation through commercial disposable gloves (2020)
- Improper glove use increases infection risk (Antimicrob Resist Infect Control, 2025)
- WHO Guidelines on Hand Hygiene in Health Care
Packing and what is included
One case contains ten dispenser boxes of 100 gloves — 1,000 gloves — in sizes S, M, L and XL, sky blue, powder-free and latex-free. The case carries one size only. Related reading: the Aurelia 3.2, 4.0 and 4.5 mil comparison, the 4.5 mil Robust glove, the 3.2 mil Transform 100 glove, and when an American clinic must change gloves within one encounter. To size a month against your own encounter count, use the clinic supply and cost planner; for a multi-site or institutional quotation, open an institutional account enquiry.
Common questions
Is it shipped from Canada?
Yes — orders ship from our Toronto warehouse.
How many cases does a small clinic use per month?
Depends on chair count and patient volume — the page spec table gives the case pack size so you can size an order against your own monthly usage.
Are these gloves sterile?
No — this 4.0 mil case is not sterile, and the page asks you to state the need if sterile gloves are required so availability can be confirmed before you order.
What does a case weigh and how is it packed?
1 case holds 10 dispenser boxes of 100 gloves — 1,000 gloves — and weighs about 5.3 kg. A case carries one size only, so a team in M and L orders 2 cases.
When is the thinner or thicker glove the better pick?
Take the 3.2 mil line when feel matters more, and a 6.0 mil glove for heavy chemical immersion. The 4.0 mil film sits between them and is the one specified as chemotherapy tested.