What Instrument and Waste Rules Apply to Cerumen Management in Canadian Audiology?

Plan view and side elevation of the six litre ultrasonic tank, drawn to scale with the working depth marked

What Instrument and Waste Rules Apply to Cerumen Management in Canadian Audiology?

Cerumen management is one of the few procedures in a hearing clinic where the instrument rules and the waste rules come from two places: CASLPO sets what happens to the curette, and Ontario's waste regulation decides where the debris goes. A curette that has been through the bath looks handled while the debris beside it is quietly treated as clinical waste. Our 6 litre benchtop ultrasonic cleaner with dual frequency is the bench piece most audiology rooms start with, because curettes and specula are small and handled between every patient.

Who may remove cerumen in Canada, and with what instruments?

CASLPO publishes practice standards for cerumen management that list the equipment an audiologist has to have: illumination and magnification to see the canal at every stage, otoscopy to assess the canal and drum before, during and after, and a removal method that runs from stainless steel or disposable curettes, hooks and forceps through to suction and irrigation. The standard is about capability rather than brand: a room is judged on what is on the trolley when the patient sits down.

How must reusable ear instruments be reprocessed?

Product information diagram of the CliniEco CS6.2 six litre ultrasonic cleaner, front elevation with the dual frequency controls

CASLPO's requirement is explicit: re-usable materials and equipment that come into contact with cerumen must be sterilized, and the processing must follow the college's infection prevention and control standards plus the manufacturer's instructions.

Instrument Contact What the standard requires
Stainless curette, hook, forceps Canal, cerumen Clean, then sterilize after each patient
Disposable curette Canal, cerumen Single use, not reprocessed, discard
Speculum, otoscope tip Canal opening Clean, then disinfect or sterilize per maker
Irrigation nozzle and tubing Canal, fluid Single use, or reprocess per maker

Cleaning comes first and is where failures start: a curette put into the bath with debris on the tip comes out looking clean. Our multi-enzyme ultrasonic cleaning solution, 4 litre concentrate is dosed for that step, and the bath is changed on a written schedule, not when it looks tired.

Plan view and side elevation of the six litre ultrasonic tank, drawn to scale with the working depth marked

Where does removed cerumen go?

Not into the biomedical waste bag by default. Ontario's waste regulation, O. Reg. 347, names the categories that make up biomedical waste, and cerumen on its own does not fall into one of them, so the debris that comes off a curette is general waste. It changes the moment blood is visible in it, or the moment a sharp is involved: then it is biomedical waste and it goes into the sharps container, not the room bin.

What does single use mean for a curette?

It means one patient, and no second trip through the bath. CASLPO is direct that items labelled for single use are not to be reprocessed, which puts a plastic curette nearer a needle cap than a stainless instrument. The practical consequence is a stock decision: a room that uses disposables for most canals and stainless instruments for difficult ones needs both lines on the bench.

Surface work between patients is the other half of the routine. A 160-wipe hydrogen peroxide canister covers the chair arm, the otoscope handle and the trolley.

Running a clinic that reprocesses instruments between patients? The clinic consumables and surgical supplies by the case page groups the cleaning, wipe and waste lines.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. Practice Standards for Cerumen Management (revised July 2023) (checked 5 November 2026)
  2. Audiology practice standards and resources (checked 5 November 2026)
  3. General — Waste Management, O. Reg. 347 (checked 5 November 2026)

Printable companion: the instrument cleaning and sterilization log records the ultrasonic bath change, the cycle number and the load release for every set that touches an ear canal.

Choosing a bath size for curettes and specula? The sterilization monitoring usage calculator turns patient volume into loads per week.

Not sure how this applies to your own setup? Ask a sterilization compliance specialist — you’ll get a written answer specific to your equipment and province, with the regulation or standard cited.

Related Reading

Frequently Asked Questions

Is cerumen management a controlled act in Ontario?

CASLPO sets practice standards for it rather than leaving it to clinic policy, and they apply to audiologists who offer the service. The requirements cover instruments, collaboration and documentation, not just technique.

Can disposable ear curettes be cleaned and used again?

No. CASLPO states that items marked or labelled for single use should not be reprocessed and must be disposed of according to the product specification, so a plastic curette gets one ear canal and then goes.

Does earwax count as biomedical waste?

Not on its own. Ontario's waste regulation names the categories that make up biomedical waste, and cerumen is not one of them; it becomes biomedical waste when visibly bloody or mixed with a sharp.

What has to be recorded for each cerumen procedure?

The instruments used and how they were processed, the removal method, what was seen before and after, and any referral. The instrument record is the part written before the patient arrives.

Last updated: October 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Already working with clinics? Become a regional representative.