What Documentation Must Accompany Diagnostic Specimens Transported Between Canadian Laboratories?
A specimen that leaves one laboratory for another carries two stories: the clinical one on the request form and the transport one printed on the outside of the 95 kPa specimen bag with a document pouch that carries it. Auditors read both, and they are rarely filed in the same place. A referral laboratory sending blocks to a pathologist two cities away is the consignor, so the sheets it hands over are the only evidence that the specimen was identified, kept cold and traceable on arrival.
What paperwork has to travel with the specimen?
| Paper | Completed by | What it has to tie together |
|---|---|---|
| Request or referral form | Sending laboratory | Patient identifiers, test requested, clinical detail |
| Specimen label | Sending laboratory | Two identifiers, collection date and time |
| Transfer log | Both, signed at handover | Who released it, who accepted it, when |
| Temperature record | Sending laboratory | Cold chain from draw to receipt |
| Transport document | Consignor | UN number, shipping name, quantity |
The request form is the clinical document and the transfer log is the legal one. Neither substitutes for the other, and a courier signature is not an accession record.

Does a Category B specimen need a dangerous goods shipping document?
By ground, Transport Canada's Transportation of Dangerous Goods Regulations exempt Category B consignments packed to the P650 instruction from the documentation parts written for higher-risk classes, which is why a courier sometimes asks for nothing beyond the bag itself. The exemption reaches the transport papers, not the laboratory record. Put the same specimen on a flight and the air rules return a declaration to the file. Claim the exemption with a leaking primary container and the consignment falls back into the full requirement.
Which laboratory standard governs the paperwork?

ISO 15189:2022 places the examination request, the referral to another laboratory and the report inside the quality system, so the file becomes auditable instead of remembered. ISO 15190:2020 covers the safety side of the same journey. In Ontario the receiving laboratory also needs a licence under the Laboratory and Specimen Collection Centre Licensing Act, and an unlicensed destination is the one defect no transfer log repairs. Containers belong inside the bag rather than beside it: a 120 mL sterile screw-cap specimen container travels in the front pocket while the form sits in the pouch behind it.
What does the receiving laboratory record on arrival?
Accession number, condition of the primary container, temperature at opening and any discrepancy against the request. A consignment that arrives at 9 °C when the request specified 2 to 8 °C is a finding whether or not the assay ran, and the receiving site writes that finding down before it discards the packaging. Where the bag itself has to be pressure rated, a 6 by 9 inch three-wall specimen transport bag, 100 per pack keeps the absorbent layer and the paperwork in one unit, which is what an inspector opens first.
Sending specimens for another laboratory to examine? The diagnostic laboratory supplies page lists the collection and transport lines that sit behind a referral volume.
Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
References
- Transportation of Dangerous Goods — shipping documents (checked 5 November 2026)
- ISO 15189:2022 — Medical laboratories, requirements for quality and competence (checked 5 November 2026)
- ISO 15190:2020 — Medical laboratories, requirements for safety (checked 5 November 2026)
Printable companion: the specimen transfer and cold chain log templates carry the same fields as the table below, so the sender fills a sheet at handover instead of reconstructing the journey from memory.
Sizing the bag and container lines for a referral volume? The clinic supply planner converts specimens per week into case quantities.
Related Reading
- Specimen Bag 95 kPa Documentation: What Canadian Labs Require
- Specimen Receipt and Processing SOP: Chain of Custody and Traceability
Frequently Asked Questions
What has to travel with a specimen sent to another laboratory?
A request or referral form, a label carrying two patient identifiers with collection date and time, a transfer log signed at handover, a temperature record, and the transport document the mode of carriage requires. The clinical and the transport records are separate obligations.
Does a Category B specimen need a shipper's declaration by ground in Canada?
Not under the P650 instruction: Transport Canada's TDG Regulations lift the documentation parts that apply to higher-risk classes for Category B consignments packed that way. The exemption covers transport papers only, so the laboratory transfer log and cold chain record stay in the file.
Who is the consignor when one laboratory sends material to another?
The laboratory that hands the package to the courier. It prepares the packaging, completes the transport document and holds the training record for the person who packed it, even when the receiving laboratory pays for the freight.
How long does the receiving laboratory keep its accession record?
For the period its own quality system and any accreditation body specify, and long enough to trace a look-back. Under ISO 15189:2022 the record is part of the examination process, not an administrative copy.
Last updated: October 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).