Which Specimen Container 120 mL Do Diagnostic Laboratories in Manitoba Order? Sizes and Case Formats

Product diagram, not a photograph: pack contents with specimen containers bagged for a laboratory order

Which Specimen Container 120 mL Do Diagnostic Laboratories in Manitoba Order? Sizes and Case Formats

A diagnostic laboratory in Manitoba does not order a specimen container because it looks right on a shelf. It orders one because the sample has to leave the building, survive a courier route and arrive at a bench where a technician reads the fill volume through a moulded graduation. Most of the province's work flows toward Cadham Provincial Laboratory in Winnipeg, and the packaging decisions follow that route rather than a catalogue page.

Which sample volumes need a 120 mL container?

Container size Typical use Fill guidance
90 mL Small urine volumes, paediatric collection Fill to the graduation, not to the rim
120 mL Midstream urine, stool, sputum Leave head space for transport
180 mL and above 24-hour collections and pooled samples Use a dedicated collection vessel

The 120 mL body is the size most benches keep for urine work, and the 120 mL sterile specimen container with a screw cap is supplied 100 per pack with moulded side-wall graduations. Smaller volumes go into a 90 mL graduated sample cup where the collection is small, and the two sizes should not be substituted casually, because the fill line a technician reads is the fill line the method assumes.

Product diagram, not a photograph: 120 mL sterile specimen container with moulded graduations and a threaded screw cap

Which case formats do Manitoba labs order?

Two formats matter: the pack of 100 that a bench can open, and the case that holds several packs. A pack of 100 is the unit of issue to a bench, and a case is the unit of purchase for the store room, so ask how many packs the case holds before you compare per-unit cost. A lab that only ever opens single packs pays a handling cost per pack; a lab that buys cases without checking the inner bundle count ends up counting loose containers at the end of the quarter.

What must the container survive before it reaches Cadham Provincial Laboratory?

Product diagram, not a photograph: pack contents with specimen containers bagged for a laboratory order

It has to survive the same pressure test the packaging is built for. Category B samples travel as a three-part system: the primary container, absorbent enough for the full volume, and a secondary package able to withstand a 95 kPa pressure differential, inside a rigid outer layer. ISO 15189 puts the quality framework around the laboratory side of that journey, and the WHO Laboratory Biosafety Manual sets out the handling principles behind it. A container that threads shut but weeps under pressure fails the journey, not the test.

Which transport bag pairs with a 120 mL container?

Pair the container with a three-wall specimen transport bag, 6 × 9 inch, 100 pack. The absorbent layer has to take the full volume of the primary container, so a bag paired with a 120 mL container needs an absorbent capacity above that figure, not a token pad. The 6 × 9 inch format holds the container upright with the requisition in the outside pocket, which is where a courier looks for it.

Which closure and labelling details cause rejections?

Three recur. A cap that is cross-threaded and feels tight: the leak appears in the bag, not at the bench. A label placed over the graduations, which hides the fill volume the technician needs to record. And a request form that does not match the container, which is a rejection before the sample is opened. A three-wall transport bag labelled with the patient and the test, paired with a container that is not overfilled, removes most of the avoidable rejections a laboratory sees in a month.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case quantities and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. ISO 15189:2022 — medical laboratories, requirements for quality and competence (checked 23 October 2026)
  2. ISO 11607-1:2019 — packaging for terminally sterilized medical devices (checked 23 October 2026)
  3. WHO Laboratory Biosafety Manual, 4th edition (checked 23 October 2026)
Sizing the order across benches? The clinic supply and cost planner turns collection volume into pack counts, and you can print the planner for the purchasing file. Sending samples to a reference laboratory? See our diagnostic laboratory supplies for the containers, bags and racks that travel together.

Related Reading

Frequently Asked Questions

What is a 120 mL specimen container used for?

It collects a single sample that has to travel: a midstream urine, a stool sample, sputum or a general collection where the receiving bench needs to read the fill volume and the container has to arrive leak-free. The moulded graduations are the reason the size is specified rather than chosen, because a fill line a technician can read at the bench is part of the record.

Does a 120 mL container fit a 95 kPa transport bag?

Yes, with room left for absorbent, which is the point of pairing the two. A Category B sample travels as primary container, absorbent, secondary packaging able to withstand a 95 kPa pressure differential, and a rigid outer layer, so the container size has to leave space inside the bag rather than fill it.

Should a lab buy pre-labelled or plain containers?

Plain containers with a separate label are the usual choice for a diagnostic laboratory, because a pre-printed label commits the whole case to one test type. If your workflow prints labels at collection, order in cases you can split across benches and keep the label stock separate.

How many containers does a Manitoba lab order at once?

Order to one quarter of collection volume plus a working reserve, and re-order against the count that comes back from the bench rather than the number issued. A lab issuing 400 containers a month should hold about 1,400 across the quarter, which is 14 packs of 100 and leaves a reserve without filling the store room.

Last updated: October 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Already working with clinics? Become a regional representative.