CliniEco Sterilization Compliance Assistant Kit — Complete Dental Sterilization Bundle
Specifications
| Type | Dental sterilization monitoring bundle |
|---|---|
| Contents | Sterilization pouches, Class 4 dual indicator, 2 boxes x 200 pcs |
| Contents | Sterilization roll, 50 m, Class 1 indicator |
| Contents | Autoclave tape, 3 rolls |
| Contents | Steam chemical integrator, Class 5, 100 pcs |
| Contents | Bowie-Dick test packs, ISO 11140-5 Type 2, 6 packs |
| Contents | Biological indicators, 24 h readout, 25 pcs |
Pricing
| Order | Unit price |
|---|---|
| 1 unit | $249.00 CAD |
| Case and carton prices are in the size table below | |
| Request quote for clinic and volume orders | |
Read the full product guide 19 sections · specs, use, compliance
This starter kit is no longer our recommended entry point. Our current programme is a monthly pack built around a fixed compliance core (biological indicators, Bowie-Dick packs and Class 5 integrators). See the subscription pack.
CliniEco Sterilization Compliance Assistant Kit — Complete Dental Sterilization Bundle
This is the bundle for a clinic that would rather place one reorder than eight. It is also the one bundle where the air-removal component needs checking first: the Bowie-Dick packs inside are for pre-vacuum (Class B) cycles, and a gravity unit would not use them. Clinics running both kinds of sterilizer usually pair it with the 24-hour biological indicator 50-pack as a spore-test refill.
Which of the eight components runs on every load, and which only once a day?
Three monitoring layers plus the equipment to read them. Chemical exposure on every package is covered by 400 Class 4 dual-indicator pouches, a 50 m roll and three rolls of indicator tape. Inside the pack, 100 Class 5 integrators respond to time, temperature and steam together. Air removal is tested by six Bowie-Dick Type 2 packs, and 25 24-hour biological indicators carry the daily spore test. A 55-60 °C dry-block incubator develops those indicators in house, and the record templates keep every result in one place.
| Monitoring layer | What the bundle includes | How often it is used |
|---|---|---|
| Chemical exposure on the package | 400 Class 4 pouches, 50 m roll, 3-roll tape set | Every package, every load |
| Steam integration inside the pack | 100 Class 5 integrators | Every load, in trays and large packs |
| Air removal | 6 Bowie-Dick Type 2 packs | First cycle of each day, vacuum sterilizers only |
| Biological (spore) test | 25 × 24-hour biological indicators | Each day the sterilizer runs |
| Incubation | 55-60 °C dry-block incubator | With every biological indicator |
| Records | Digital log and BI tracking templates | End of every cycle day |
What does the bundle cost, and what does it replace in a monthly order?
One kit is $249.00 and arrives as a single line item: three monitoring layers, 25 spore tests, the incubator and the digital records. Bought separately, the same list is eight products, eight stock levels and eight orders to chase, which is the routine this bundle is meant to remove. It is sized for a practice running daily cycles on one or two sterilizers. A group with several sites should ask for a volume quote rather than stacking single kits on one order.
Do I need a separate incubator after buying this bundle?
No — a 55-60 °C dry-block unit is in the box, which is the range a 24-hour biological indicator needs to develop, and it takes the indicators supplied with the kit. The block holds the indicators supplied with the kit at the temperature a 24-hour spore test needs to develop, so the daily result is read in house rather than sent out. Keep it on a bench in the sterilization room and record each well on the tracking sheet.
Start with the printable cycle record and the log generator; for a written answer on your own setup, use the compliance desk.
Sold and shipped in Canada by CliniEco Medical, MDEL #35334.
Everything your dental or medical clinic needs to run a complete, audit-ready sterilization program — pouches, rolls, indicator tape, Class 5 integrators, Bowie-Dick tests, biological indicators (spore tests), a dry-block incubator, and free printable record sheets. One kit, one trusted partner, zero guesswork.
Why Clinics Choose CliniEco
✅ Complete Compliance Package (chemical + biological monitoring) | ✅ Free Shipping $99+ (ON) / $199+ (rest of Canada) | ✅ No Minimums | ✅ Authorized Distributor
What's Included — 8 components, every item fully specified:
1. Sterilization Pouches — Class 4 Dual Indicator (2 boxes × 200 pcs)
- Class 4 multi-variable chemical indicator — internal & external dual indicators per ISO 11140-1
- ISO 11607-1 packaging standard — validated seal integrity for steam sterilization
- Self-sealing adhesive strip — no heat sealer required for pouches
2. Sterilization Roll — Continuous Roll (1 roll × 50m)
- 50m roll with Class 1 process indicator (paper & film) — cut to any instrument size
- Multi-ply medical-grade paper — balanced porosity for steam penetration
- Flexible packaging — ideal for large or oddly shaped instruments
3. Autoclave Tape — Sterilization Indicator (3 rolls)
- Chemical indicator stripes — darken on successful steam exposure (ISO 11140-1 Type 1)
- Heat-activated adhesive — holds secure through the cycle
- Perforated for easy tearing — no scissors needed
4. Steam Chemical Integrator — Class 5 (100 pcs)
- Class 5 integrating indicator — responds to time, temperature, and steam presence (ISO 11140-1)
- Penetrates the pack interior — verifies conditions inside wrapped instruments
- Used for every load — strongest in-package verification before release
5. Bowie-Dick Test Pack — ISO 11140-5 Type 2 (6 packs)
- Daily air-removal test — detects air leaks and inadequate vacuum (ISO 11140-5)
- Meets RCDSO/PHO expectations — standard first-cycle-of-the-day test in Ontario dental clinics
- Single-use, ready-to-run — no assembly required
6. Biological Indicators (Spore Tests) — 24h Rapid Readout (25 pcs) ⭐ NEW
- Daily spore testing — required for Ontario dental clinics (RCDSO): one BI per sterilizer on every day it is used
- Geobacillus stearothermophilus ATCC 7953 — 10⁶ spores, ISO 11138-3
- 24-hour readout — no fluorescent reader required, works with any 55-60°C dry-block incubator
- No equipment lock-in — a 24-hour vial turns colour and reads by eye in any standard dry-block incubator, with no proprietary reader in the loop
7. Dry-Block Incubator (55-60°C) ⭐ NEW
- Dedicated BI incubation — the exact temperature range for spore test development (ISO 11138-3)
- Universal compatibility — works with our BIs and most standard 24h spore tests
- No proprietary reader required — standard dry-block design held at the 55–60°C the spore test calls for
- Compact benchtop design — fits any sterilization room
8. FREE: Digital Compliance Record Tools
- Sterilization log template — per-cycle records ready for RCDSO/PHO audit
- Biological indicator tracking sheet — daily BI results documented automatically
- Maintenance & recall checklist — annual IPAC self-assessment support
- Delivered by email after purchase — digital download, no shipping needed
💡 Why this is a complete compliance package: Ontario dental standards require chemical monitoring (every load), Bowie-Dick testing (daily, vacuum sterilizers), and biological monitoring (daily in Ontario — RCDSO). This kit covers all three layers — plus the incubator and digital records to prove it at audit.
Quality & Compliance
All sterilization consumables are tested to ISO 11140-1, ISO 11140-5, ISO 11138-3, and ISO 11607-1. CliniEco Medical is a Canadian medical device establishment under Health Canada MDEL #35334.
Clinic & Volume Pricing
- $249 per kit — complete sterilization compliance package (comparable retail value $423+)
- Free shipping over $99 in Ontario · $199 rest of Canada (Ontario) / $199 (rest of Canada)
- No minimum order, no contracts
Why Buy
- Save 40%+ vs buying sterilization supplies separately — one box, everything included
- Full 3-layer compliance — chemical + Bowie-Dick + biological, the whole audit story
- No equipment lock-in — our BIs work with standard incubators, not proprietary readers
- Audit-ready records — digital templates included free
- Local Toronto warehouse — fast Ontario delivery
Clinic & Volume Orders
Need monthly sterilization supplies for a multi-chair practice or dental group? Request wholesale pricing for recurring delivery: Request a Quote →
Have a question about your own facility? Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. Ask your compliance question.
Related Guides
Learn how to choose and use this product correctly:
Related articles
- How to Choose a Biological Indicator Incubator for a Canadian Clinic
- 24-Hour Self-Contained Biological Indicators: Pack Sizes, Incubation and the Record
- How Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering
- Medical Waste Disposal in Canada: Provincial Rules, Pickup and Cost for Clinics
Common questions
What is actually included in the kit?
Eight specified components: sterilization pouches with Class 4 dual indicators, sterilization roll, indicator tape, Class 5 integrators, Bowie-Dick tests, biological indicator spore tests, a dry-block incubator, and free digital record-keeping tools. Chemical and biological monitoring are both covered.
Is one kit enough for a single-operatory dental clinic?
It is built around a single-operatory clinic running its own sterilizer. Sizing is driven by how many loads you run per week, so the pouches and roll cover routine instrument sets while the indicator and spore test counts cover monitoring frequency.
Does the kit cover both chemical and biological monitoring?
Yes, both layers are included. Chemical indicators are used on every load to confirm the cycle parameters were met, and biological indicators are used to confirm the sterilizer actually killed spores on each day the sterilizer is used.
Are the pouches validated for steam sterilization?
The pouches use a Class 4 multi-variable chemical indicator with internal and external indicators, made to the ISO 11140-1 indicator standard and the ISO 11607-1 packaging standard, with a self-sealing adhesive and validated seal integrity for steam sterilization.
How does buying the kit compare with ordering the items separately?
The kit puts all eight components under one order and one price, which is the figure shown on this listing. Buying the same items individually means eight line items and eight prices to track, and it leaves you assembling a monitoring programme item by item, which is where gaps between chemical and biological monitoring usually appear.
What happens if I need help setting up the monitoring routine?
The bundle includes free digital record-keeping tools so the log format is already defined. Free shipping applies once an order passes the threshold shown in the cart, and there are no minimum order quantities.
Do I still need a biological indicator (spore test)?
Yes — in Ontario, the RCDSO requires a biological indicator for each sterilizer on every day that it is used (daily monitoring). This kit includes 25 spore tests plus the incubator to run them in-office — no mail-in lab required.
What sterilizer is this compatible with?
All items are for steam sterilization (gravity & vacuum cycles) — compatible with standard autoclaves used in Canadian dental clinics.