How many gloves does a Canadian dialysis unit use per treatment session?

CliniEco biohazard waste bag, red, 30 gallon, leak-proof, 5-pack

How many gloves does a Canadian dialysis unit use per treatment session?

A four-hour hemodialysis session is not four hours in one pair of gloves. The count follows the station rather than the clock: every entry and exit spends a pair. A six-station unit running three shifts works through a 1,000-glove case of 3.5 mil nitrile exam gloves in about four treatment days.

That is the number a renal program should budget on, and it is not the number most units carry in their head. Glove use in dialysis is usually guessed from patient volume, which misses the cleaning half of the work.

How many glove changes happen in one treatment session?

Task at the station Pairs What is being handled
Cannulation and access dressing 1 needle, catheter hub, dressing
Machine set-up and connection 1 blood lines, dialyser, settings
Intra-treatment checks 2 blood pressure, access site, alarms, two rounds
Disconnection and post-treatment dressing 1 haemostasis, then hand hygiene
Station clean-down between patients 2 surfaces, machine exterior, waste
Session total 7 pairs fourteen gloves

CliniEco 3.5 mil blue nitrile exam gloves, 1,000 gloves per case

Two units of the same size can report counts a case apart because of the last row. Where environmental services takes the clean-down, nursing counts five pairs and the housekeeping budget carries the other two, and the gloves are reordered twice by two people.

Why is the station the unit of count, not the patient?

Public Health Ontario's environmental cleaning guidance treats each hemodialysis station as an individual entity: hand hygiene is performed on entry to the station and again on exit, before any other task in the unit. Disposable items taken to a station are disposed of there, and unused supplies do not return to a clean area. That is a pair spent at every boundary, whether the boundary is a new patient or a shift change.

CliniEco biohazard waste bag, red, 30 gallon, leak-proof, 5-pack

What does a six-station unit use in a day?

Eighteen sessions at seven pairs is 126 pairs, which is 252 gloves. Across twenty-one treatment days that is 5,292 gloves, or about five and a quarter cases. Hold par at one case per station on the shelf, and reorder when the shelf reaches one case, not when it empties.

Which glove is worn for each task?

Routine access care runs in a clean non-sterile exam glove. Where the unit's written procedure classifies the step as aseptic, a sterile procedure glove replaces it, which is the distinction Public Health Ontario draws rather than a blanket rule for the whole session. Nitrile rather than latex, given how often a renal patient reports a latex allergy. Long wet work at the machine moves to the textured 4.5 mil fully textured nitrile glove, which keeps grip on wet tubing.

Station clean-down runs on hydrogen peroxide wipes and a 6 mil heavy-duty nitrile glove that holds up to a scrub. Material from a station is biomedical waste and goes into a red 30 gallon bag thick enough that nothing leaks while it is carried out.

Ordering for a renal program or a multi-site group? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

The clinic consumables range groups the gloves, wipes and waste bags a renal unit reorders on the same schedule.

References

  1. Environmental cleaning for prevention and control of infections in all health care settings — Public Health Ontario, PIDAC (checked 13 November 2026)
  2. Routine practices and additional precautions for preventing the transmission of infection in healthcare settings — Public Health Agency of Canada (checked 13 November 2026)
  3. Infection prevention and control for clinical office practice — Public Health Ontario (checked 13 November 2026)

Printable companion: the SOP document package holds the station cleaning procedure and the record fields a renal program is asked for at review.

Run the station count into cases per month with the clinic supply planner.

Related Reading

Frequently Asked Questions

How many gloves does one hemodialysis session use?

Seven pairs, or fourteen gloves, when the station clean-down is counted. Nursing-only counts stop at five pairs and book the clean-down to environmental services.

Is the count based on treatment time?

No. It is based on station entries and exits. A four-hour session and a three-hour session carry the same glove count if they touch the station the same number of times.

Should cannulation be done in sterile gloves?

Routine access care runs in a clean non-sterile exam glove. Where the unit's written procedure classifies the step as aseptic, a sterile procedure glove is worn instead.

Where does the station waste go?

Blood-contaminated waste from a station is biomedical waste, and the bag has to be thick enough that nothing leaks in handling.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.