Dental Extraction Forceps #150: Sizes, Markings and Colour Codes Explained

Three 24-hour biological indicators from a 25-pack, shown beside their packaging

Dental Extraction Forceps #150: Sizes, Markings and Colour Codes Explained

A Dartmouth practice ordered four "150 forceps" from three suppliers and received three different instruments: a 15 mm beak, a 17 mm beak, and one with a serrated hinge box. All four worked. The purchase order was still the weak link, because "150" names a pattern rather than a size, and nothing on the handle records which variant arrived. Between patients the instrument goes back into the same loop as the rest of the tray: a Class 4 self-sealing dual-indicator pouch, then steam.

What does a number 150 extraction forceps do?

It is the upper universal pattern, shaped for maxillary teeth that leave along one conical root: incisors, canines and most premolars. The beak is seated parallel to the long axis, the handles close across the buccal and lingual plates, and the tooth is delivered with a slow buccal force rather than a twist.

Lower teeth take a different beak curvature, which is why the 151 exists. Multi-rooted molars take a heavier pattern: 13 and 23 for upper right and left, 18L and 18R for the lower arch, or a 32 cowhorn when the crown is broken down.

Pattern Arch Root form it suits Typical seat
150 Upper Single, conical Incisors, canines, premolars
151 Lower Single, conical Incisors, canines, premolars
13 and 23 Upper right and left Two or three, divergent Molars
18L and 18R Lower Two, divergent Molars

Class 4 self-sealing sterilization pouch, box of 200, with the external process indicator and write-on panel visible

What do the markings on a forceps handle actually record?

Etching is identification, not sizing. A reusable instrument carries the maker's name or symbol and often the material grade, and a practice that tracks sets adds its own mark. What the handle does not carry is a beak width, a jaw curvature or a pattern number.

One detail is worth checking before a spec sheet is signed. The corrosion-resistance test quoted for reusable hand instruments changed edition: ISO 13402:1995 was withdrawn on 7 March 2025 and replaced the same day by ISO 13402:2025. A supplier page still citing the 1995 edition is describing a superseded test — a fair question on a tender line.

Are extraction forceps colour coded by size?

Three 24-hour biological indicators from a 25-pack, shown beside their packaging

No, and the coloured ring is the most over-read feature on a dental instrument. A band or a dob of paint usually encodes a tray, a set or an ownership group inside a sterilisation container, and two suppliers can use the same colour for different patterns. No colour code exists for extraction forceps; trust the catalogue number.

Where colour does carry meaning is on the packaging. The external process indicator on a heat-seal sterilization roll changes when the pack has been through a cycle, which records that the load was processed — not that the forceps is sterile. Back it with a 24-hour self-contained biological indicator on the schedule your sterilizer and province require.

How is a forceps reprocessed between patients in Canada?

Clean first. A hinged instrument with a box lock holds debris, so it goes into an ultrasonic bath with a multi-enzyme ultrasonic cleaning solution rather than straight into a washer-disinfector. Then pack and process under the manufacturer's written instructions, issued under ISO 17664-1:2021, with the CSA Z314 series setting the Canadian framework around them. Then record the cycle against the set. A forceps that no longer closes flush, or rocks on the hinge pin, is a replacement decision rather than a sharpening one.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B ordering collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

Outfitting a general or specialty practice? Our dental practice supplies page groups the consumables that sit around the extraction tray.

References

  1. ISO 13402:2025 — Surgical and dental hand instruments: resistance to autoclaving, corrosion and thermal exposure (published 7 March 2025, replacing the 1995 edition) (checked 31 October 2026)
  2. ISO 17664-1:2021 — Processing of health care products: manufacturer information for processing critical and semi-critical devices (checked 31 October 2026)

Printable companion: the sterilization log templates give each instrument set a place to record the cycle, the load and the indicator result.

Would your current loop survive a records review? The sterilization self-check walks the same points in the order an inspector would.

Related Reading

Frequently Asked Questions

What is the difference between a number 150 and a 151 forceps?

The arch, not the size. Both are universal, but the beak on a 151 follows the mandibular arch so the handle clears the lower incisors.

Does the number on an extraction forceps handle tell you the pattern?

Usually not. The etched marking identifies the maker and often the material grade, and a practice may add its own set code. The pattern lives on the catalogue and the invoice.

Can a number 150 forceps be used on a maxillary molar?

It is the wrong tool for a multi-rooted tooth. Divergent roots need a heavier molar pattern such as 13, 23 or 18L, or the crown tends to fracture at the furcation.