CSA Z1220:24 Inspections: The First Aid Kit Questions an OHS Officer Asks

Blue nitrile examination gloves counted against a kit contents list during an inspection

CSA Z1220:24 Inspections: The First Aid Kit Questions an OHS Officer Asks

CSA Z1220:24 Inspections: The First Aid Kit Questions an OHS Officer Asks

A physiotherapy clinic on the second floor of a medical building, mid-morning. The officer is not carrying the standard and does not read it aloud. She asks for the kit, opens it on the reception counter, and starts talking. Within four minutes she has asked eight things, and seven of the eight have a written answer somewhere in the building — in a clause of CSA Z1220:24, in the regulation that applies to the clinic, or in the clinic's own procedure.

The value of listing the questions is that most clinics prepare for the wrong one. They buy a bigger kit. What the officer is checking is whether the clinic can answer, in the order asked, without leaving the counter.

What are the eight questions a clinic kit attracts?

The eight below cover the whole inspection in practice, and each has an owner: a clause of the standard, a provision of the regulation, or a document the clinic writes itself. Getting the ownership right is the difference between a finding and a conversation.

Question Where the answer comes from What the officer is testing
Which edition are you working to? Scope note and edition history in CSA Z1220:24 Whether the paperwork and the box agree
Which type of kit is this, and why? Clause 6, selection by workers per shift; Clause 5 for classification Whether the kit matches the workforce
What is inside, and how do you know? Clause 5 minimum contents; your contents list Whether the count is real or asserted
Who owns this kit? The 2024 addition of organizational and worker roles and responsibilities Whether anyone is accountable
When was it last checked? Clause 8 for maintenance; your procedure for the record Whether maintenance happens or is claimed
Is the container marked? Clause 7, container and marking requirements Whether the kit is identifiable and protective
What have you added, and why? Annex A split into specialized and additional items Whether extras are justified or accumulated
Is anything expired or damaged? Dates and symbols under ISO 15223-1:2021 Whether the contents are usable today

Which edition are you working to?

This is the question that ends most inspections early, because the answer is often a mismatch. CSA Z1220:24 is the second edition and supersedes the 2017 edition, which CSA Group lists as withdrawn. A clinic whose binder quotes the 2017 edition while the supplier ships to the 2024 edition has two documents describing one box.

The answer to give is not simply the newer edition. The standard's scope note is explicit that legislation differs from jurisdiction to jurisdiction in Canada and that the user is responsible for confirming requirements with the authority having jurisdiction. So the honest answer is the one your regulator's rule produces: if your jurisdiction's regulation cites a CSA edition, that edition is your baseline; if it sets its own contents table, that table is, and the standard explains the reasoning behind kits of that shape.

What the officer will not accept is a shrug. A one-line entry in the procedure — the edition you work to, the date you confirmed it, and who confirmed it — closes the question in seconds.

Which type of kit is this, and why?

Type is a headcount question, and clinics routinely answer it with a floor plan. Clause 6 of the 2024 edition selects a kit for a workplace environment based on the number of workers at the workplace per shift. Not patient visits, not square footage, not the number of treatment rooms.

The classifications themselves come from the system the standard has carried since the first edition: Type 1 Personal, Type 2 Basic and Type 3 Intermediate, with Types 2 and 3 further classified into small, medium and large to match headcount, and with the intermediate kit intended for higher risk environments. The 2024 preface names three changes and reclassification is not among them, so that structure is the one to answer with.

Here the federal regulations are a useful contrast rather than an answer. For federally regulated workplaces, Schedule I of SOR/86-304 sets type by employee count: type A for two to five employees, type B or C for six or more depending on the certificate the attendant must hold, and type D for a single worker detached in a remote workplace. The letters are different, the tables are different, and a clinic that quotes A to D while holding a Type 2 kit has answered two systems at once.

What is inside, and how do you know?

Aurelia #2 cotton roll carton on a clinic supply shelf, dated stock kept behind open stock

The 2024 edition revised kit contents for user clarity, and the operational reading is that the list is meant to be usable by the person who opens the box. An officer who asks what is inside is testing whether the clinic can produce a count rather than a recollection.

Three documents close it. A contents list inside the lid, written in item names a hygienist recognises. A dated count with initials. And a refill routine that holds stock in the format the kit carries, so the count stays true between checks. Nitrile gloves are the item that exposes a weak routine fastest, because they leave the kit in pairs and are replaced from a carton stored somewhere else: a case of Aurelia Protégé 4.0 mil nitrile exam gloves, 1,000 to the case is the right reserve, and it belongs next to the kit rather than in a supply cupboard on another floor.

Tape is the second tell. It is consumed in lengths nobody records, so the count drifts quietly: a 1 inch cloth medical tape, 36 rolls to the case is a year of kit refills for a small practice and a simple thing to hold behind the box.

Who owns this kit?

The 2024 edition added organizational and worker roles and responsibilities. That change is easy to read as boilerplate and it is not: it puts the organization and the worker into the document as parties with defined roles, which means a kit with no accountable person now fails a question the standard can be read against.

The clinic answer is one named owner and one named deputy, both in the written procedure, with the check frequency and the holiday arrangement stated. The officer's follow-up is always the same — "and if that person is away?" — and a clinic that has to think about it has already answered.

When was it last checked, and where is the record?

This is where the standard deliberately steps back, and where most clinics have nothing. Clause 1.3 (b) states that CSA Z1220:24 does not apply to requirements for workplace first aid incident reporting and recording, which it says can be subject to the authority having jurisdiction or organizational policies. The standard requires ongoing maintenance under Clause 8 and declines to set your record format.

The regulator may not decline. In the federal regulations, Subsection 16.5 (4) requires the employer to inspect every first aid station regularly and at least monthly, and to ensure contents are maintained in a clean, dry and serviceable condition. The same regulations put a record book inside the kit: item 15 of Schedule II is "Record book: First Aid", one per kit, for types A, B, C and D alike.

Duty CSA Z1220:24 Federal SOR/86-304
Record of the check Clause 1.3 (b) excludes recording and leaves it to the authority having jurisdiction or to policy A First Aid record book is part of the kit contents under Schedule II item 15
Check frequency Clause 8 requires ongoing maintenance and sets no single frequency First aid stations inspected regularly, at least monthly, under Subsection 16.5 (4)
Kit classification Type 1 Personal, Type 2 Basic, Type 3 Intermediate, the last two split by size Types A, B, C and D assigned by employee count in Schedule I

That contrast is the most useful thing a clinic can take from this article. The standard tells you the kit is maintained; the regulation tells you who writes it down. A clinic that keeps a monthly sheet with a date, a count, initials and any action taken satisfies both readings at once, in one page.

Is the container marked?

Clause 7 covers the kit container and its marking requirements, and the question is usually a glance rather than a test. What the officer looks for is a container that identifies itself, closes, and keeps contents clean and dry.

In clinics the failure is rarely dramatic. It is the kit that migrated into a drawer, the lid that no longer latches, or the label that says "STAFF" with no indication that it holds first aid supplies. Marking is the least costly fix on this list and the one most often deferred.

Blue nitrile examination gloves counted against a kit contents list during an inspection

What have you added, and why?

Before 2024, optional contents sat together in Annex A. The 2024 edition separates them into specialized items and additional items, and the separation gives a clinic a defensible way to answer the question of why a gauze pad, an eye pad and a burn gel are all in the same box.

Specialized items answer a hazard that belongs to a named environment — marine, mining, forestry, transportation, pools, school buses — which the standard places outside its own scope where other legislation applies. Additional items answer a hazard your own risk assessment identified: the cleaning chemicals in the utility room, the workshop at the back, the staff who open alone at seven in the morning. Annexes A and B provide informative guidance on conducting that risk assessment and on selecting additional supplies for special circumstances.

One hard limit belongs on the same page. Under the federal regulations, Subsection 16.7 (4) states that prescription drugs or other medications not set out in Schedules II, III and IV shall not be stored in first aid kits or with first aid supplies. Clinic stock of any prescription product should live in its own labelled place, and the workplace kit should stay a kit.

Is anything expired or damaged?

The dates in a kit are not decoration, and the symbols beside them follow ISO 15223-1:2021, the standard for symbols used with information supplied by the manufacturer: batch code, use-by date, single use, sterile barrier. An officer who turns a pouch over is reading those symbols, and a clinic that has never read them cannot answer.

The useful rule is that the date is a claim about a barrier, not a countdown that survives abuse. A sterile barrier claim traces to a packaging system validated under ISO 11607-1:2019, and it holds only while the pouch is stored as stated. A crease that has become a channel, a wet corner or a scuff along the seal ends the useful life of that pouch whatever the print says. Where contents were sterilized, the route is on the label because residue and validation differ: ethylene oxide under ISO 11135:2014, or moist heat under ISO 17665:2024.

The same rotation discipline applies to the dated stock behind the kit. Cartons on a clinic shelf rotate on the same first-expired-first-out basis as the kit itself, which is the reason the shelf and the box should be checked in the same pass rather than a week apart.

What can the standard not be used to prove?

Three things, and each is worth saying plainly when a supplier's email implies otherwise.

The standard cannot certify a clinic. It sets requirements for kits, not for premises, and its scope note hands the legislative question back to the authority having jurisdiction. The standard cannot replace your regulator's contents table where one exists. And the standard says nothing about first aid rooms or first aid stations, which Clause 1.3 (a) excludes, so a question about either belongs to the regulation that applies to you.

What a supplier can evidence is the product. CliniEco Medical works under MDEL #35334, and Health Canada's MDEL application instructions set out what an establishment licence covers, including the annual licence review. On the technical side, the manufacturer's quality system sits under ISO 13485:2016, its risk work under ISO 14971:2019, and skin-contact materials are evaluated under ISO 10993-1:2025. A single sterile dressing in the box, such as the 4 by 4 inch sterile self-adhesive foam dressing, is the unit those documents describe — and the unit an officer actually looks at.

What should be in the folder at the front desk?

One page, plus the kit. The page carries the edition you work to and the date you confirmed it; the owner and deputy; the check frequency; the last three dated counts with initials; the additional-items list from the risk assessment; and the manufacturer documentation for anything sterile in the box.

That folder is what turns eight questions into one answer, and it takes an afternoon to build. The alternative is what most clinics do: answer seven questions well and lose the eighth.

Building the folder for a practice, a care home or a multi-site group? Wholesale and multi-site ordering covers case quantities and account setup, and the B2B wholesale collection lists the lines we hold for institutional buyers. Reselling? Become a distributor.

References

  1. CSA Z1220:24 — First aid kits for the workplace, second edition (2024), preface, scope and edition history — CSA Group (checked 2 November 2026)
  2. CSA Z1220-17 — First aid kits for the workplace, first edition (withdrawn, R2021) — CSA Group (checked 2 November 2026)
  3. Canada Occupational Health and Safety Regulations, SOR/86-304, Part XVI and Schedules I to III — Justice Laws Website (checked 2 November 2026)
  4. ISO 15223-1:2021 — Medical devices: symbols to be used with information supplied by the manufacturer — Genorma (checked 2 November 2026)
  5. ISO 11607-1:2019 — Packaging for terminally sterilized medical devices: sterile barrier systems — Genorma (checked 2 November 2026)
  6. ISO 13485:2016 — Medical devices: quality management systems — Genorma (checked 2 November 2026)
  7. ISO 14971:2019 — Medical devices: application of risk management — Genorma (checked 2 November 2026)
  8. ISO 10993-1:2025 — Biological evaluation of medical devices, Part 1 — Genorma (checked 2 November 2026)
  9. ISO 11135:2014 — Sterilization of health-care products: ethylene oxide — Genorma (checked 2 November 2026)
  10. ISO 17665:2024 — Sterilization of health care products: moist heat — Genorma (checked 2 November 2026)
  11. Medical device establishment licence application form instructions — Health Canada (checked 2 November 2026)
  12. Standards Support Tools — First Aid Kit Items, inspection checklist and inspection poster — CSA Group (checked 2 November 2026)

Printable companion: the free log and template centre has a kit inspection sheet that records the eight answers below on one page, dated and initialled.

Most inspection findings are quantity findings, not content findings, and the clinic supply and cost planner converts your headcount into the monthly quantities that keep a kit above its minimum between checks.

Related Reading

Frequently Asked Questions

Will an OHS officer inspect my clinic against CSA Z1220:24?

The officer inspects against the regulation of your jurisdiction, not against the standard directly. The standard's scope note states that workplace first aid legislation differs from jurisdiction to jurisdiction and that the user is responsible for confirming requirements with the authority having jurisdiction. Most kit questions end up at the standard anyway, because it is what the regulation's contents table rests on.

What do I show if I have no inspection log?

Show what you have in the order it exists: the written procedure that names the owner, the contents list inside the lid, and the last dated count. If none of those exist, say so and start the log the same day. Clause 1.3 (b) of the standard leaves recording to the jurisdiction or to organizational policy, so the gap is a policy gap, not a kit gap.

Are CSA kit types the same as the federal A to D types?

No. CSA Z1220 describes Type 1 Personal, Type 2 Basic and Type 3 Intermediate, with Types 2 and 3 split into small, medium and large. The federal Canada Occupational Health and Safety Regulations use types A, B, C and D set by employee count in Schedule I, with contents in Schedule II. The two systems are not interchangeable on one order.

Who should be named as the owner of a clinic kit?

One named person plus a named deputy, both written into the procedure with the frequency of the check. The 2024 edition added organizational and worker roles and responsibilities to the standard, so a kit with no accountable person is the first thing the role change was written to prevent.

What counts as a marked container?

A container that identifies itself as a first aid kit, closes, and keeps contents clean and dry. Clause 7 of CSA Z1220:24 covers the container and its marking requirements. A cardboard box with a handwritten label is weak on all three counts, mostly because it stops closing after a month.

Do we need a first aid room under CSA Z1220:24?

No. Clause 1.3 (a) states that the standard does not apply to requirements for first aid rooms or first aid stations. That obligation, where it exists, comes from the regulator: the federal regulations, for example, require a first aid room where 200 or more employees are working at any time.

Can expired stock stay in the kit if the seal looks fine?

No. The date on a sterile pouch is the manufacturer's claim that the barrier will keep contents sterile to that date, and the claim rests on the packaging system being validated under ISO 11607-1:2019 and handled within the stated conditions. A creased, wet or scuffed pouch has lost the claim whatever the date says.

Last updated: October 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).