Is it cheaper to buy Class 5 chemical integrators in 200 per pack or in bulk cases for a four-chair dental practice in Ontario? Load Release Math

CliniEco Class 5 steam chemical integrator specification card, ISO 11140-1 Type 5, 121 to 135 degrees C

Is it cheaper to buy Class 5 chemical integrators in 200 per pack or in bulk cases for a four-chair dental practice in Ontario? Load Release Math

Two boxes of the same strip sit on a shelf in most dental steri rooms: one is a 200-strip pack that was ordered when the drawer ran low, the other is part of a case. The strip is identical. The reason one practice pays $899.50 a year for 10,000 integrators and another pays $790.00 is the unit the order was written in.

The strip is a CliniEco steam chemical integrator, Class 5 to ISO 11140-1 Type 5, 200 strips per pack, reading yellow to black across 121 to 135 C, with a case of five packs, 1,000 strips, at $79.00.

How many Class 5 integrators does a four-chair practice use in a year?

One integrator goes inside each pack, so the count is the pack count. Forty appointments a day over 21 working days is 840 packs a month, and 840 a month is 10,080 a year.

CliniEco Class 5 steam chemical integrator specification card, ISO 11140-1 Type 5, 121 to 135 degrees C

Integrators a month Integrators a year Packs a year Cases a year Case price a year
420 5,040 25 5 $395.00
840 10,080 50 10 $790.00
1,260 15,120 76 15 $1,185.00

Where does the case of five packs start to pay?

At the first case. Five 200-strip packs bought one at a time are $89.95, and the case of five is $79.00, so the case is $10.95 less for the same 1,000 strips. Over a year at the middle row, 50 packs come to $899.50 and ten cases to $790.00, which is $109.50 less.

CliniEco 24-hour biological indicator, 25 per pack, three indicators shown with the pack

Unit Strips Listed price
200-strip pack 200 $17.99
Five packs, bought singly 1,000 $89.95
Case of 5 x 200 1,000 $79.00

Does one integrator go in every pack or one per load?

Every pack. Public Health Ontario's clinical office practice guidance requires an internal chemical indicator inside each package, container or bundle that is being sterilized, and the type 5 strip is that indicator for a wrapped pack. A clinic that puts one strip in the load instead is not short of stock, it is short of a record for every pack in it. Rigid containers take two, in diagonally opposite corners.

Can a Class 5 integrator replace the weekly biological indicator?

No, and the distinction is the one buyers get wrong. A type 5 strip reads the critical parameters of the process it sat in, so it can release that load. A biological indicator asks a different question: whether the sterilizer still kills spores. Ontario's guidance sets out a daily spore test for each day the sterilizer is used, plus the air-removal check for a dynamic air removal sterilizer, and the Bowie-Dick test pack, six tests to a box covers that check. The 24-hour biological indicator, 25 per pack is the spore test itself, and CSA Z314 describes how both fit into a release decision.

Running a dental practice in Ontario? See our dental practice consumables.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. Public Health Ontario, Infection Prevention and Control for Clinical Office Practice (checked 17 November 2026)
  2. Health Canada, Medical devices (checked 17 November 2026)

Printable companion: the clinic supply and cost planner turns appointment counts into integrator packs and cases before the order goes in.

Recording the result of each load? The printable load log has a column for the integrator and a column for the spore test, which are not the same record.

Not sure how this applies to your own setup? Ask a sterilization compliance specialist — you’ll get a written answer specific to your equipment and province, with the regulation or standard cited.

Related Reading

Frequently Asked Questions

How many integrators does a four-chair practice use in a year?

With 40 appointments a day over 21 days and one integrator per pack, the draw is 840 a month, which is 10,080 a year.

Does the case always beat the pack on total?

For this listing, yes: five packs bought singly are $89.95 and the case of five is $79.00, so each case saves $10.95 for the same 1,000 strips.

Can one integrator cover a whole load?

No. In Ontario the internal chemical indicator goes inside each package, so the count follows packs. A rigid container takes at least two, diagonally opposite, because steam has to be read along the path it travels.

Does the integrator replace the spore test?

No. It supplements the biological indicator and does not replace it; the integrator releases a load, the spore test tells you whether the process still works.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.