What between-patient decontamination steps apply to a Canadian ambulance stretcher and cots?

Hydrogen peroxide disinfecting wipe can for surface disinfection between patients

What between-patient decontamination steps apply to a Canadian ambulance stretcher and cots?

Between two calls, a paramedic crew has minutes, not an hour. The stretcher still carries the last patient's skin cells, the belts have been handled with gloves, and the cot pad has absorbed what came through the sheet.

The sequence is short and ordered. Cleaning removes the soil; disinfection inactivates what is left, with a product that carries a Drug Identification Number, such as PerOxy disinfecting wipes, DIN 02519275, 160 wipes per can, and a disinfectant wiped onto a soiled mattress does neither job properly.

What does between-patient cleaning mean on an ambulance?

Two stages in a fixed order, applied to the surfaces the last patient touched. Canadian practice starts from Routine Practices: surfaces contaminated with blood or body fluids, or in contact with non-intact skin, are cleaned and disinfected before the vehicle carries another patient.

Which parts of the stretcher and cot need attention?

Aurelia PerOxy disinfecting wipes, 0.5% hydrogen peroxide, DIN 02519275, 160 wipes per can

The mattress upper surface and sides, the belts and straps, the side rails, the cot pad and the floor beneath the cot. The belts are the item crews skip: fabric, handled constantly, and only wiped when a checklist names them. A ready-to-use wipe suits the rails, belts and small surfaces where a bucket and cloth are impractical.

Must the disinfectant carry a DIN?

Yes, for a healthcare-grade surface product. Health Canada assigns the Drug Identification Number, and a product without one is a cleaner rather than a disinfectant. The label also states the wet contact time, which is the requirement, so a quaternary product asking for ten minutes is not satisfied by a five-second wipe.

Item Between-patient step Indicator that it was missed
Stretcher mattress clean, then disinfect the upper surface and sides grey residue at the seams
Belts and straps wipe both faces, allow contact time before reuse still damp or body fluid at the buckle
Side rails and controls clean and disinfect handles and buttons fingerprints on the control panel
Cot pad follow the pad manufacturer's instruction pad re-used wet

Hydrogen peroxide disinfecting wipe can for surface disinfection between patients

How long does the surface have to stay wet?

For the time printed on the label. Accelerated products are chosen because their contact times fit a turnaround, while slower chemistry belongs to the deep clean. Two cloths, one for cleaning and one for disinfection, and a used cloth never goes back into the container.

What belongs on the shift record?

A record that names the unit, the call, the surfaces covered, the product and its DIN, the contact time and who signed. The deep clean flag matters as much, because a heavily contaminated vehicle returned to service without that note leaves the next crew no way to know.

Where does hand hygiene fit?

Before the cleaning step, not only after patient contact. Ontario's Patient Care and Transportation Standards (v2.7, August 2022) list hand hygiene before cleaning and decontamination of equipment and vehicles. In practice the gloves come off, hands are cleaned with DermaSeptyl 2-in-1 hand sanitizer, 12 by 60 mL, NPN 80122015, and only then is the compartment worked through, which is also how the cab stays clean. Vehicles with a mounted dispenser run on 1200 mL foam refills.

Supplying a paramedic service or clinic fleet? The cleaning and disinfecting range and the hand sanitizer line cover the two steps in the sequence.

Buying for a service or a multi-site operation? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

References

  1. Environmental cleaning for prevention and control of infections in all health care settings, 3rd ed., Public Health Ontario (checked 24 November 2026)
  2. Patient Care and Transportation Standards v2.7, Ontario Ministry of Health (checked 24 November 2026)
  3. Environmental control in healthcare facilities, U.S. Centers for Disease Control and Prevention (checked 24 November 2026)

Printable companion: the vehicle cleaning log gives the unit, the surface list, the product and the contact time a place on one sheet.

Working out wipes and hand hygiene volumes for a fleet? The supply planner turns calls per shift into case quantities.

Related Reading

Frequently Asked Questions

Does the whole patient compartment have to be disinfected between calls?

The high-touch and horizontal surfaces do, including the stretcher mattress, belts, rails and the floor under the cot. A full compartment wash belongs to the deep clean, which is triggered by heavy contamination rather than by every call.

What happens if the mattress cover is torn?

It comes out of service. A cracked or torn cover cannot be cleaned to a reliable standard because the foam underneath holds soil and moisture, so the mattress is replaced rather than wiped more thoroughly.

Can a cleaner and a disinfectant be replaced by one product?

Only if the product is labelled as both and the surface is not heavily soiled. Where there is visible blood or body fluid, the soil is removed first, because organic load consumes the active ingredient and the labelled contact time is then meaningless.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.