What will a Canadian infection control auditor check about glove use and storage?

Light blue nitrile examination glove on a hand, powder free

What will a Canadian infection control auditor check about glove use and storage?

The audit rarely starts with technique. It starts with a box. An auditor looks at where the gloves are sitting before watching anyone put a pair on. A box on the reception desk, a box on a keyboard, a box open in a corridor: each is a finding that has nothing to do with the gloves themselves.

What is in the box matters as much. The CliniEco nitrile exam gloves, 3.5 mil, 1,000 gloves per case and the Aurelia Absolute 100 exam gloves are both medical devices; an industrial glove bought from a hardware supplier is not, and no clinic wants to explain that distinction at the chair.

How does an auditor tell a medical glove from an industrial one?

By the words on the carton. Health Canada classifies medical gloves as Class II medical devices and states that a Class II device cannot be imported or sold unless the manufacturer holds a medical device licence, so the label has to declare a medical use with words such as examination or medical grade. Industrial gloves must not suggest a medical use. A carton marked for general purpose sitting in a treatment room is the finding, and it is one of the few a clinic can fix the same day.

What does the glove standard actually measure?

CliniEco nitrile exam glove, 3.5 mil, blue, 1,000 gloves per case

Water tightness, and the acceptable quality level is where buyers get caught. Canada references ISO 11193-1 or ASTM D3578 for examination gloves, both of which set a pinhole failure limit of 2.5 per cent when a glove is filled with 1,000 mL of water and read twice. EN 455-1 sets the same test at 1.5 per cent. A glove certified to the Canadian-referenced limit is compliant; the tighter figure is the honest way to compare two cartons.

Check What passes What is written up
Label wording examination, medical grade general purpose, industrial use
Fit size range on the shelf one size, stretched at the cuff
Storage original carton, off the floor decanted into unlabelled bins
Rotation lot and expiry legible expired box in a treatment room

Powder and protein limits sit alongside the pinhole test. Ontario's glove selection checklist, drawn from its occupational dermatitis guidance, sets powder-free gloves below 2 mg of powder and 50 ppm of protein per glove, and powdered latex below 250 ppm of protein, which decides whether a latex-sensitive clinician can work in the room.

What hand hygiene step frames every pair?

Light blue nitrile examination glove on a hand, powder free

Two, and neither is optional. Alcohol-based rub or soap and water before donning, and hand hygiene again after doffing, with gloves removed between patients and never washed. Applying rub to a gloved hand is a finding: the alcohol attacks the nitrile and leaves a glove that looks intact on an unclean hand.

What does an auditor look at in the storage room?

Four things, all visible in a minute: cartons on a shelf rather than on the floor, no direct sunlight or heat source, no storage beside a sterilizer or an electrical panel where ozone shortens shelf life, and a rotation where the oldest carton is in front. A lot number that cannot be read on the carton is enough to fail the traceability question even when the gloves are in date.

What else does the auditor connect to the glove decision?

The gown cuff. Gloves are worn over the cuff, so a clinic that buys short-cuffed gloves and long-sleeved gowns ends up with a gap at the wrist that shows on the first splash. The Aurelia Protégé 4.0 mil examination gloves cover the heavier tasks where a 3.2 mil glove is the wrong choice, and the ordering question is which task needs which wall thickness, not which carton is on offer.

Ordering for a clinic, pharmacy group or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

Stocking a treatment room? The clinic consumables page groups gloves with the gowns, masks and wipes that run out at the same time.

Printable companion: the free compliance log set includes a storage and rotation sheet; the supply and cost planner sizes a glove order against patient volume by size. Ask a compliance specialist if a label or a certification is unclear.

References

  1. Medical gloves — Health Canada (checked 12 November 2026)
  2. Glove selection checklist — Public Health Ontario (checked 12 November 2026)
  3. Specifications on gloves, standards and acceptable quality levels — Government of Canada (checked 12 November 2026)

Related Reading

Frequently Asked Questions

Are gloves required at the reception desk?

No. Gloves belong at the point of care; a box beside a keyboard signals gloves are being used instead of hand hygiene.

Can you use alcohol hand rub on gloved hands?

No. Alcohol degrades nitrile; hand hygiene happens before donning and after doffing.

How many sizes does a clinic have to stock?

As many as its staff need. A single size stretches at the cuff and tears.

Do gloves need to be stored away from the sterilizer?

Yes. Heat and ozone age the elastomer, so cartons stay off the floor and away from warm equipment.