How many single-use equipment covers does a Canadian imaging department use per month?
Imaging departments rarely run out of "covers". They run out of one specific piece, usually the cassette cover, three days before month end, while two other sizes sit untouched. The reason is that a monthly cover order gets built from the exam count, and a cover set is not one item: a radiographic cassette, the table, and an ultrasound probe each take a different barrier, and only one of them is consumed at the rate the spreadsheet assumed. A 250 mL conductive gel shows the same coupling from the other side, because a probe cover is useless without the gel that goes under it.
What counts as a single-use equipment cover?
Three families in a general imaging department: cassette and detector-plate covers for radiography, table and patient-positioning covers, and probe covers for ultrasound. Mammography adds paddle covers, and fluoroscopy adds a drape over the image intensifier.
Each comes off at the end of the exam and does not go back on, which is why the count tracks exams rather than shifts.
How does an exam count turn into pieces per month?

| Cover type | Per exam | 60-exam day | 22 working days |
|---|---|---|---|
| Cassette or plate cover | 1 | 60 | About 1,300 |
| Table or positioning cover | 1 to 2 | 60 to 120 | 1,300 to 2,600 |
| Ultrasound probe cover | 1 | 12 to 20 | 260 to 440 |
| Mammography paddle cover | 1 per view pair | 20 to 30 | 440 to 660 |
The table is why a department should order by piece and by size, not by "cover" as a category. One size at 1,300 pieces a month and another at 400 is a different purchasing problem from a blended average.
Does a cover replace cleaning between patients?
No, and this is the assumption that turns an inspection into a finding. CDC's guideline on disinfection and sterilization in healthcare facilities treats barriers as protection for surfaces that are difficult to clean or that sit between the patient and the equipment. The barrier has to be changed between patients, and if it slips, tears or is left off, the surface underneath has to be cleaned and disinfected before the next patient.

A cover that stays on for a whole list is not a barrier. It is a contaminated surface with a plastic film over it.
What does the manufacturer owe the department?
For a device that only contacts intact skin, or never contacts the patient at all, ISO 17664-2:2021 sets out the processing information the manufacturer has to provide: preparation, cleaning, disinfection, drying, inspection and storage. That document is where a department confirms whether the housing can be wiped with the product it has on the shelf, and whether the cover is required by the maker or adopted as local practice.
A cover the maker requires cannot be swapped for one the department simply prefers.
How should the monthly order be sized?
Build it from exams, not from last month's invoice: count exams per modality, multiply by pieces per exam, then add the QC and training buffer that never appears on a patient schedule. Ordering by average leaves one size dead and another rationed.
Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
Equipping a treatment or imaging room? Our clinic consumables page groups the wipes, gels and single-use items that support a room.
References
- CDC, Guideline for Disinfection and Sterilization in Healthcare Facilities (2008) (checked 10 November 2026)
- ISO 17664-2:2021, Processing of health care products — Information to be provided by the medical device manufacturer for the processing of non-critical medical devices (checked 10 November 2026)
Printable companion: the free printable room and equipment cleaning log templates include an imaging room sheet for barrier changes and surface cleaning.
Sizing monthly barrier and gel volume from exam counts? The clinic supply planner converts exams per day into piece and case counts.
Related Reading
- What compression paddle covers and positioning aids do Canadian mammography sites reorder?
- Which Disinfection Level Applies to Endocavity Ultrasound Probes in Canadian Clinics?
- How are contrast media supplies tracked and documented in a Canadian imaging clinic?
Frequently Asked Questions
Is a cover set one item or several?
Several. A radiographic cassette typically takes a cassette cover, the table takes a sheet, and an ultrasound probe takes its own cover, so a single exam can consume two or three pieces that are counted on one line.
Does using a cover mean the equipment does not need cleaning?
No. Barriers protect surfaces that are hard to clean or that sit between patients, and they have to be changed between patients; if a barrier is torn or slipped, the surface underneath still gets cleaned.
Which covers apply to a non-critical device?
The device's own instructions decide. ISO 17664-2:2021 covers the processing information a manufacturer must supply for a non-critical device that only contacts intact skin or does not contact the patient at all.
How many pieces does a 60-exam day use?
Roughly 120 to 180 pieces across cassette, table and probe covers. At 22 working days that is a monthly order in the thousands, not the hundreds.
Last updated: October 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).