A biological indicator incubator is a small piece of equipment that quietly decides whether a daily monitoring programme is credible. It holds the indicator vials at a controlled temperature for a defined period, and if the temperature drifts, the wells are contaminated, or the routine is inconsistent, the reading at the end carries less weight than the log suggests. The routine is simple, but it has to be the same every day, because the value of a biological indicator comes from comparing today against yesterday.
The setup most clinics run is a dry-block unit holding a batch of vials, such as the DLAB HB105-S1 dry bath incubator, used with the 24-hour rapid-readout biological indicator.

What temperature should the incubator hold?
The incubation temperature is set by the indicator manufacturer and is printed in the product instructions, and it must be held for the full incubation period rather than only brought close at the start. That is why the unit should be allowed to stabilise before vials go in, and why a unit that is switched on at the start of a shift and loaded immediately gives an unreliable first reading. Checking the set temperature against the instructions whenever a new box of indicators is opened catches the common error of incubating a new format at the temperature of the old one.
How many wells does a clinic need?
Well count follows the number of indicators incubated at once. A single-chair clinic running one indicator a day needs only a small number of wells, plus a spare or two for a repeat test, while a multi-chair practice incubating a control alongside each test needs proportionally more. Buying a unit with a few spare wells costs less than buying a second unit later, and it also gives somewhere to put a retest without disturbing the running batch.

What does the daily routine look like?
Label the vials so the batch is identifiable, include a control vial where the format requires one, load them without pushing the caps loose, and record the load time and the set temperature in the monitoring log. Read at the end of the incubation period, record the result against the log row for the cycle being verified, and remove the vials for disposal once the result is recorded. The routine matters more than its duration, because a consistent sequence is what makes a run of results comparable.
How should the incubator be maintained?
Check the wells for residue or spillage at each batch change, since a contaminated well can affect the reading, and follow the manufacturer cleaning instructions rather than a general-purpose cleaner. Note the set temperature at each load so a drift is visible in the log rather than discovered at the next audit. Where the unit is shared between rooms, keep it in one fixed position, because moving a dry-block unit between benches is a common cause of a changed reading environment.
| Element | What to do | Why it matters |
|---|---|---|
| Set temperature | Per the indicator instructions, checked at each load | The reading depends on the incubation temperature |
| Warm-up | Let the unit stabilise before loading | Loading early makes the first reading unreliable |
| Well count | Enough for the daily batch plus a retest | A spare well avoids disturbing a running batch |
| Labelling | Identify each vial to its cycle row | Connects the result to the load it verifies |
| Recording | Load time, temperature and result in the log | Turns the batch into a traceable record |
Where to Buy Biological Indicator Incubators in Canada
CliniEco Medical supplies these from Ontario with published CAD pricing (MDEL #35334) — no quote required, and every indicator pack ships with its lot number printed on it so the incubation batch in your log can be traced back to the box it came from.
| Item | Pack / format | Price (CAD) | Cost per test | Order |
|---|---|---|---|---|
| 24-hour dry-block incubator | 24 wells | $379.00 | — | CliniEco 24-hour biological indicator incubator, 24-well dry block |
| DLAB HB105-S1 dry-block incubator | 20 wells | $599.00 | — | DLAB HB105-S1 20-well dry-block incubator |
| 24-hour self-contained BI | 25-pack | $69.99 | $2.80 | 24-hour self-contained biological indicator, 25-pack |
| 24-hour self-contained BI | 50-pack | $109.99 | $2.20 | 24-hour self-contained biological indicator, 50-pack |
| 24-hour self-contained BI | 100-pack | $189.00 | $1.89 | 24-hour self-contained biological indicator, 100-pack |
| 3-hour fluorescence rapid BI | 50-pack | $249.99 | $5.00 | 3-hour fluorescence biological indicators, 50-pack |
Which sterilizers and indicators these units fit: both dry-block units hold 55–60 °C for the 24-hour self-contained indicator, which is validated for 121 °C gravity-displacement and 132 °C vacuum-assisted (pre-vacuum) steam cycles. The 24-well unit holds a full day's batch for a practice running two sterilizers; the 20-well unit covers a single chair plus control and retest wells. A 3-hour fluorescence indicator covers the same two steam cycles but has to be read in the fluorescence reader, not in a dry block. Ethylene oxide, dry-heat and hydrogen-peroxide sterilizers need a different indicator biology and sit outside this table — check the cycle type printed on the unit before ordering.
How many packs to hold: sterilizers × test days × cycle types = vials per week. One sterilizer tested on every day it is used, five working days a week, runs 5 vials a week, so the 25-pack covers about five weeks and the 100-pack about four months; two sterilizers on that schedule need 10 vials a week, which makes the 50-pack the five-week size and the 100-pack the ten-week size. Add one vial for every extra cycle type run on the same day, and keep a spare pack for the repeat tests that follow a positive result.
Stock and shipping: every item in the table is held in stock in Toronto and ships from Ontario, with the lot number printed on each indicator pack so the entry in your monitoring log can be traced back to the batch. We do not quote a delivery date at checkout.
Related reading
Two companion articles cover the surrounding routine: 24-hour biological indicators and fast verification and the daily sterilization log checklist for Ontario. The standards and printable records sit in the sterilization compliance hub.
Frequently Asked Questions
Can a biological indicator be incubated without a dedicated incubator?
It needs a controlled temperature held for the full incubation period, which is what an incubator provides. Incubating in an uncontrolled spot produces a reading that cannot be compared with previous days, so a dedicated unit is the practical choice.
How many incubator wells does a one-chair clinic need?
Enough for the indicators incubated at once plus a spare or two for a repeat test. A small dry-block unit covers a single chair comfortably, and the spare wells matter when a retest is needed.
Why does the incubation temperature have to be checked every day?
Because the result depends on it. Recording the set temperature at each load makes a drift visible in the log rather than it being discovered later, when the earlier readings can no longer be relied on.
Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
Download the printable monitoring log sheet, run the log generator to record incubation batches, request a 24-hour biological indicator 25-pack, or ask a sterilization compliance specialist to review the routine.
CliniEco Medical is a licensed medical device establishment (MDEL #35334).
Buying these together: the 24-hour biological indicators, Bowie-Dick test packs and Class 5 integrators described above are also supplied as the monthly compliance pack, built per practice size so the fixed compliance core arrives on one invoice instead of three separate reorders.