MTC Bio's SureSeal S™ 1.5 mL microcentrifuge tubes are the general-purpose workhorse tube in most research and clinical labs: a conical polypropylene tube with a full-size attached snap cap, a ring and groove liquid-tight seal, and a self-standing bag that keeps the tubes upright on the bench. This page covers the whole SureSeal S 1.5 mL family we stock — clear, coloured and opaque black tubes, packed either as one 500-tube bag or as ten bags of 50 — so you can pick the configuration that matches how your bench actually works.

What is a 1.5 mL snap-cap microcentrifuge tube?
A 1.5 mL microcentrifuge tube is a small conical tube used to hold, spin, heat and store small volumes of liquid — typically 50 µL to 1.5 mL. "Microcentrifuge" refers to the benchtop centrifuge these tubes are spun in, which reaches much higher g-forces than a standard lab centrifuge. "Snap cap" here means the lid is moulded onto the tube on a flexible hinge and presses over the rim, seating an inner ring into the neck. There is no separate threaded closure to lose or cross-thread, and the cap opens one-handed.
The SureSeal S tube is moulded from BioClear™ co-polymer, an advanced polypropylene chosen for clarity and centrifugal strength. The cap has a frosted marking surface for pencil labelling, and the closure uses a ring and groove design: the ring on the cap seats into a groove on the tube neck, which produces a liquid-tight seal while keeping the twisting force needed to open and close the tube low — useful when you are capping hundreds of tubes in a session, or working in gloves.
Which pack format should you buy: one 500-tube pack or ten bags of 50?
Both formats give you 500 sterile tubes. The difference is how they arrive on your bench, and that changes which one is the better buy for a given lab.
- One 500-tube self-standing bag is the lowest-cost-per-tube format and the right choice for a bench that pulls tubes steadily through a shared workflow. The gusseted bottom lets the bag stand up on the bench, so the tubes stay upright and accessible without a rack.
- Ten bags of 50 costs slightly more per pack for the same 500 tubes, but keeps the bulk of your stock sealed while you work through one small bag at a time. That is the format most labs choose for clean benches, cell-culture rooms and any workflow where an open 500-tube bag would sit out for weeks.
If you are unsure, start with the single 500-tube bag for general molecular work and switch to the 10 × 50 format once a specific bench needs smaller working units.

Specifications at a glance
| Property | SureSeal S 1.5 mL tube |
|---|---|
| Nominal volume | 1.5 mL |
| Tube style | Conical bottom, graduated, self-standing in bag |
| Material | BioClear™ co-polymer (advanced polypropylene) |
| Closure | Attached snap cap (hinged), ring and groove liquid-tight seal, frosted writing surface; Stop-Pops™ locking clips supplied, 10 per bag |
| Centrifugal strength | Tested up to 28,000 × g |
| Usable temperature range | −90 °C to +121 °C |
| Nuclease and pyrogen status | RNase free, DNase free and pyrogen free |
| Sterility | Sterile as standard, by electron beam irradiation |
| Packaging | Self-standing bag with gusseted bottom; 500 tubes per pack |
| Caps and accessories | Stop-Pops™ cap locks supplied — 10 per bag |
Two of these numbers matter more than the rest when you are choosing a tube. The 28,000 × g rating tells you the tube is built for high-speed benchtop spins rather than only gentle pelleting. The −90 °C to +121 °C range means the same tube can go from a −80 °C freezer into a boiling water bath or an autoclave cycle without a material change, which is why labs standardise on one tube across freezer, bench and heat steps.

Snap cap and locking clips: how the closure actually works
The SureSeal S tube uses an attached snap cap. The lid is moulded onto the tube on a flexible hinge, so it cannot be dropped, lost or cross-threaded, and it opens one-handed. The seal is a ring and groove: a moulded ring on the inside of the cap seats into a groove in the neck of the tube and locks with a click. MTC describes the closure as a liquid-tight seal that needs less locking force than a threaded cap, which is what makes the tube comfortable to open and close hundreds of times a day. The cap also has a 2 mm syringe-permeable circle — thinner plastic that lets you draw a sample through a closed cap instead of opening it.
Stop-Pops™ locking clips come with every bag, ten per bag. A clip presses over a closed cap and holds it shut mechanically, which is the configuration to use when the tube will be:
- stored frozen at −20 °C or −80 °C,
- heated, boiled or placed in a heat block,
- transported between rooms, buildings or sites.
If your protocol requires a threaded screw cap — for vapour-phase nitrogen storage, or for a closure that is turned rather than pressed — choose a screw-cap tube instead. Every tube on this page uses the same attached snap cap.
Clear, coloured or opaque black: which tube should you choose?
Colour is a workflow tool, not decoration. Choose by what you need to see and what you need to protect.
| Configuration | Colour | Pack format | Best for |
|---|---|---|---|
| Clear, single bag | Natural / clear | 1 × 500-tube self-standing bag | General molecular work where you need to see the pellet and the liquid level |
| Clear, split bags | Natural / clear | 10 bags of 50 | Clean benches and cell-culture rooms that keep stock sealed until use |
| Blue | Blue | 1 × 500-tube self-standing bag | One sample type or one protocol per colour across a shared bench |
| Red | Red | 1 × 500-tube self-standing bag | Hazard-adjacent or high-attention samples; second colour in a two-colour scheme |
| Green | Green | 1 × 500-tube self-standing bag | Third colour in a coding scheme; easy visual sorting at a glance |
| Orange | Orange | 1 × 500-tube self-standing bag | High-visibility coding for tubes that leave the bench |
| Purple | Purple | 1 × 500-tube self-standing bag | Coding schemes that need six or more distinct groups |
| Yellow | Yellow | 1 × 500-tube self-standing bag | Light-sensitive workflows where a bright tube is easier to spot in a rack |
| Opaque black | Opaque black | 1 × 500-tube self-standing bag | Light-sensitive reagents and fluorescent work where stray light must not reach the sample |
The practical rule most labs settle on: clear for anything you need to inspect visually, one colour per sample type or per operator, and opaque black for anything photolabile. Colour is in the tube body, not a coating, so it does not rub off in a water bath or on a labelling wipe.
What fits inside a 1.5 mL tube, and what does not?
A 1.5 mL tube holds a working volume well below its nominal volume once you account for the conical base, the liquid you need to vortex without splashing into the cap, and the headspace the cap plug needs to seal cleanly. As a working guide:
- Routine reactions and digests: 20 µL to 500 µL sits comfortably and spins without wetting the cap.
- Sample storage: up to about 1 mL is the practical ceiling for tubes that will be frozen and thawed repeatedly.
- Anything that needs more than about 1.2 mL should move up to a 2.0 mL tube rather than being overfilled.
If you regularly run volumes above 1.2 mL, or you need a tube for larger pellets, a 2.0 mL microcentrifuge tube in the same cap family is the correct next size rather than a compromise fill in a 1.5 mL tube.
Which jobs are these tubes right for — and which need a different tube?
These tubes are documented for enzyme digests, DNA isolation and purification, centrifugation, incubation, and general sample and reagent storage. That covers most of the day-to-day work in a molecular or analytical lab.
They are the wrong tube when:
- you need a thin-wall tube for fast thermal cycling — a dedicated PCR tube or strip gives better heat transfer,
- you are spinning at forces a benchtop microcentrifuge cannot reach — use a tube rated for the rotor you actually run,
- you need a cryogenic vial for vapour-phase nitrogen storage, which has a different closure and thread design,
- you need a tube that can be autoclaved repeatedly — single-use sterile tubes are intended for one workflow, not for repeated reprocessing.
For thermal cycling in strips or plates, pair these tubes with your PCR consumables rather than substituting them. If you are setting up a new lab bench from scratch, our lab consumables range with parafilm and serological pipettes covers the sealing and liquid-handling side, and graduated 90 mL specimen cups cover larger-volume collection. Both are in stock and ship from the same warehouse as these tubes.
Where should you store sterile tubes: bench, fridge or freezer?
The tube tolerates −90 °C to +121 °C, but the pack does not. Sterility is a property of the sealed bag, and it is lost the moment the bag is opened in a non-sterile environment. The working rule is:
- Keep unopened packs at room temperature, away from direct sunlight and solvent vapours. There is no need to refrigerate sealed sterile consumables, and cold storage adds condensation that wets the bag on removal.
- Treat an opened bag as a working stock. Keep it closed between uses, keep it off the floor, and keep it out of the fridge — a cold bag drawn into a warm room collects condensation on the tubes.
- Do not autoclave the pack. The tubes are supplied sterile by electron beam irradiation; a second sterilisation cycle is unnecessary and the bag is not designed for it.
- Once a sample is inside, the tube follows your sample's storage rules — −20 °C or −80 °C for frozen storage, up to boiling for heat steps.
How should you label tubes and keep lot records?
Label the tube body or the cap, not the bag. The cap has a frosted writing surface intended for pencil, which survives freezer storage and does not smudge when the tube is handled with gloves. Adhesive labels work on the tube wall, but they can lift in a water bath, so use them for short-lived bench work rather than archival storage.
For lot traceability, record the lot number from the bag label against the date the bag was opened and the bench it was assigned to. Each lot ships with its manufacturer documentation, and the certificate of analysis for the lot can be requested with the lot number when you need it for an audit file. If your quality system requires the documentation with the delivery, ask for it on the purchase order and we will attach it to the shipment.
Who should use SureSeal S tubes?
These tubes suit:
- research and academic labs running digests, isolations and general sample handling,
- clinical and veterinary labs that need a sterile, nuclease-free tube for sample preparation before analysis,
- food, water and environmental testing labs that need a consistent, documented tube for multiple methods,
- teaching labs that want one tube format across a semester, in colours that make sorting and storage straightforward,
- any lab standardising on a single 1.5 mL tube to simplify ordering, storage and training.
Because the tubes are sterile, nuclease free and pyrogen free as standard, they also suit workflows where an unsterile tube would force an extra cleaning or depyrogenation step.
How many packs does a typical lab order?
A pack is 500 tubes. For planning:
- A single bench running a moderate daily workload typically works through one pack in three to six weeks.
- A shared lab with four to eight benches usually orders two to four packs at a time so individual benches can hold their own colour.
- Labs that keep every bench on the same clear tube order the larger single-bag format, and split it into smaller working bags on site.
Order the colours you actually use rather than a mixed assortment — a colour that no bench is assigned to becomes dead stock. If you are setting up a colour scheme for the first time, start with clear plus two colours and add a third once the workflow settles.
Ordering, shipping and compliance notes
All configurations on this page are sterile, single-use laboratory consumables. They are not medical devices and are not intended for diagnosis, treatment or direct patient contact. Shipping is from local stock, and both the Canadian and US storefronts ship these tubes from the warehouse that serves the destination country.
Individual packs can be mixed within an order, so a lab can order clear and two colours in the same shipment. If you need a configuration that is not listed, or a quantity above the standard pack size, contact us with the catalogue code and we will confirm availability before you order.
Related reading
Common questions
Which pack format should I buy: one 500-tube pack or ten bags of 50?
Both formats contain 500 sterile tubes. The single 500-tube self-standing bag is the lower-cost-per-tube option for a shared bench. Ten bags of 50 keep the bulk of the stock sealed while one small bag is in use, which suits clean benches and cell-culture rooms.
Screw cap or snap cap: which one do I need?
Choose a screw cap when the sample will be frozen, heated, spun at high g-force or transported. The ring and groove seal on these tubes stays liquid-tight, and every bag includes ten Stop-Pops cap locks for archival storage or shipping.
Clear, coloured or opaque black: which tube should I choose?
Use clear tubes when you need to see the pellet and the liquid level. Use one colour per sample type or per operator as a coding scheme. Use opaque black for light-sensitive reagents and fluorescent work.
What temperature range do these tubes handle?
The tubes are rated from minus 90 degrees Celsius to plus 121 degrees Celsius and tested up to 28,000 times gravity, so the same tube can go from a minus 80 degrees Celsius freezer into a heat block or water bath.
How many packs does a typical lab order?
A single bench usually works through one 500-tube pack in three to six weeks. A shared lab with four to eight benches typically orders two to four packs so each bench can hold its own colour.