MTC Bio 4.5 mL Blood Bank Transfer Pipettes — P4115-00

MTC Bio 4.5 mL Blood Bank Transfer Pipettes, Graduated to 2 mL

SKU CLI-TPIP-4.5-P4115-00 · MTC Bio
$408.11$479.80
In stock · ships from Toronto, ON
Transfer pipette · 4.5mL · blood bank · graduated to 2mL · non-sterile · buconfiguration
2configuration options
CLI-TPIP-4.5-P4115-00sku
Laboratory Consumablescategory
Configuration · 2 options
Health Canada licensed importer & distributor · MDEL #35334 · Ships from Toronto
Free shipping over $99 in Ontario · $199 rest of Canada

Specifications

SKUCLI-TPIP-4.5-P4115-00
BrandMTC Bio
CategoryLaboratory Consumables
AvailabilityIn stock
Ships fromToronto, ON

Pricing

OrderUnit price
1 unit$408.11 CAD
Case and carton prices are in the size table below
Request quote for clinic and volume orders
Volume pricing is quoted per order — most quotes go out within one business day.
Read the full product guide 8 sections · specs, use, compliance

MTC Bio 4.5 mL blood bank transfer pipettes graduated to 2 mL, bulk packs of 250 and sterile packs of 500, shipped from North American stock.

The blood bank pipette is a shape rather than a volume: long enough to reach into a segment or a tube, graduated to 2 mL so a plasma or cell suspension volume can be estimated in the pipette, and sized at 4.5 mL so a full draw covers a typical serology step. This page lists the non-sterile bulk pack and the sterile individually wrapped pack of the same pipette.

What is in a case of blood bank pipettes?

The non-sterile bulk configuration holds 250 pipettes per pack and 20 packs per case, so 5,000 pipettes. The sterile individually wrapped configuration holds 500 per case.

Bulk is the working stock for a serology bench that goes through pipettes steadily; the sterile wrapped pack is for a step that must come from an unopened wrapper, which is the format a transfusion service usually documents.

The sterile pack is wrapped individually rather than in peel packs, which matters for a transfusion service: a wrapper can be opened over a clean field without a second bag to dispose of, and each wrapper carries the lot.

When is the graduated 4.5 mL pipette the right tool?

When a volume has to be estimated inside the pipette rather than in a cylinder: adding a plasma aliquot to a tube, taking a cell suspension from a segment, or splitting a small volume between two tubes. The 2 mL graduation covers those steps, and the 4.5 mL capacity gives headroom for a full draw.

Where a volume has to be measured to a tolerance, this is not the tool: the graduation is moulded, and a serological pipette or a pipettor is the correct instrument. The pipette is for transfer with an estimate, not for measurement with a record.

In serology the pipette is often used to take an aliquot from a tube that will be returned to storage, so the tip must not touch the bench or the tube rim; a long body and a short draw make that easier than a short pipette with a large bulb.

The 4.5 mL body also holds enough for a two-step transfer without a second draw, which is why the format survived in blood bank work after pipettors became common.

What are the specifications of the 4.5 mL blood bank pipette?

Every configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.

Configuration Manufacturer reference Pack Case
Transfer pipette · 4.5mL · blood bank · graduated to 2mL · non-sterile P4115-00 250 per pack 5,000 per case
Transfer pipette · 4.5mL · blood bank · graduated to 2mL · sterile · i P4115-11 500 per pack 500 per case

How many pipettes does a serology bench use?

A bench doing 50 transfers a day uses 50 pipettes, about 1,100 a month, so a 5,000-pipette bulk case lasts four to five months. A transfusion service using sterile wrapped pipettes at 20 a day uses about 420 a month, so a 500-count case lasts five weeks.

Because the two configurations differ by a factor of ten in case count, a bench that switches between them mid-quarter usually ends up with a part case of each; decide which step needs sterile and stock accordingly.

Transfusion services often run a small number of tests with a high documentation requirement, so pipette consumption tracks test count rather than sample count, and a monthly count of tests is the better reorder input.

Working pattern Used per month Case covers
One bench, light use about 300 pieces roughly 8 months
One bench, full shift about 2,000 pieces roughly 2 months
Two benches about 4,000 pieces under one month

Counts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.

How is it shipped, and what documentation comes with it?

Pipettes ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. The sterile pack carries the manufacturer reference and lot on the wrapper.

Store bulk packs closed and dry, and keep the sterile pack sealed until the step that needs it. A polyethylene pipette left in sunlight takes a set and will not draw the same volume.

Where a wrapper is retained for the record, write the lot on the worksheet at the time of use: the wrapper itself is usually discarded before the record is reviewed.

If a bulk pack is kept in a drawer rather than the carton, keep it in the bag: a loose pipette picks up dust and the bulb collects it.

What we do not claim

Single-use laboratory consumables for liquid transfer in serology and blood bank workflows. Not sold as medical devices for patient treatment, and not a calibrated measuring instrument; the graduation is a moulded estimate.

What we cannot do is confirm that a pipette meets a specific standard for a transfusion workflow: send the standard reference and we will check the manufacturer documentation rather than assume.

Frequently asked questions

How many pipettes per case?

The non-sterile bulk configuration is 5,000 per case in 20 packs of 250; the sterile individually wrapped configuration is 500 per case.

What is the graduation?

Graduated to 2 mL, moulded on the pipette as an estimate rather than a calibrated measurement.

Is the sterile version individually wrapped?

Yes, the sterile configuration is individually wrapped, 500 per case.

Why is this called a blood bank pipette?

The shape and the 2 mL graduation suit serology and transfusion workflows, where a plasma or cell suspension volume is estimated during transfer.

Can it be used for cell work?

The sterile wrapped configuration is the one intended for sterile work; bulk non-sterile packs should stay on non-sterile steps.

Choosing the right option

Related products in the same laboratory line:

Background reading before you order:

Laboratory consumables

Common questions

How many pipettes per case?

The non-sterile bulk configuration is 5,000 per case in 20 packs of 250; the sterile individually wrapped configuration is 500 per case.

What is the graduation?

Graduated to 2 mL, moulded on the pipette as an estimate rather than a calibrated measurement.

Is the sterile version individually wrapped?

Yes, the sterile configuration is individually wrapped, 500 per case.

Why is this called a blood bank pipette?

The shape and the 2 mL graduation suit serology and transfusion workflows, where a plasma or cell suspension volume is estimated during transfer.

Can it be used for cell work?

The sterile wrapped configuration is the one intended for sterile work; bulk non-sterile packs should stay on non-sterile steps.