Insulin Syringes 1 cc — 31G × 5/16", 100/Box
Not currently offered for sale in Canada. Use the button below to enquire about availability, lead time and documentation.
Insulin syringes with a 1 mL barrel and a 31 gauge needle, supplied 100 per box. The 1 mL barrel with half-unit or unit graduations is the format used for the smallest doses, where a larger barrel would make the dose hard to read.
This page documents the specification, sizing logic and sourcing position for these syringes for Canadian clinics, pharmacies, diabetes education programs and care homes.
Who it is for
- Diabetes education and outpatient clinics
- Community pharmacies running injection programs
- Long-term care homes administering insulin
- Public health and travel clinics
Specifications
| Barrel | 1 mL with fine graduations |
| Needle | 31G, short bevel |
| Format | 100 per box |
| Intended use | Insulin administration |
| Status | Specification listing — availability pending supplier documentation |
Frequently asked questions
Why does syringe barrel size matter for insulin?
Dose accuracy. A 1 mL barrel gives more space between graduations than a 3 mL barrel, so small doses are easier to read — which is also why insulin is commonly supplied in dedicated 0.3 mL, 0.5 mL and 1 mL formats.
What does 31G mean?
Needle gauge, or outside diameter: 31G is thinner than 29G or 30G, which usually means less injection discomfort. Thin needles require more care with injection technique.
Can facilities buy syringes without a prescription?
In Canada, the licensing classification of the device determines what documentation a supplier must hold. This listing is being prepared against that requirement; pricing and ordering will be enabled once it is complete.
How do I ask about volume supply?
Use our B2B enquiry form. We will confirm documentation status and lead times.
What do 1 cc, 31G and 5/16 inch each specify?
Three numbers, three different jobs. One cc is one millilitre of barrel capacity, and on a U-100 scale that barrel holds 100 units, so each unit is one hundredth of the barrel. 31G is the needle's outside diameter: 0.25 mm in the ISO 9626:2016 designated size series, finer than 30G at 0.30 mm and coarser than 32G at 0.23 mm. Five sixteenths of an inch is 7.94 mm of needle length, a short needle that reaches subcutaneous fat in most adults. The barrel is the part that decides dose accuracy, because graduation spacing shrinks as capacity grows: a 1 mL barrel leaves visibly more space between marks than a 3 mL barrel for the same dose. That is why insulin is drawn in 0.3, 0.5 or 1 mL formats rather than in whatever general-purpose syringe is nearest to hand.
Which standard covers an insulin syringe, and which one does not?
ISO 8537:2016 is the document written for this device: sterile, single-use syringes, with or without needle, intended solely for the injection of insulin and filled by the end user. ISO 7886-1:2017, the general standard for manual single-use hypodermic syringes, states in its scope that it excludes syringes for use with insulin and points instead to ISO 8537. A supplier sheet that cites only ISO 7886-1 for an insulin syringe is citing the wrong document, even when the same factory makes both product lines. Tubing dimensions come from ISO 9626:2016, sterilisation from ISO 11135:2014 or the ISO 11137 series, the sterile barrier from ISO 11607-1:2019, and the manufacturer's quality system should be certified to ISO 13485:2016. Both were confirmed as current at their last review, and both have a replacement in progress at ISO, so the edition belongs on the specification sheet.
Why does the concentration on the vial have to match the scale?
A U-100 vial contains 100 units of insulin per millilitre, the concentration used for almost all human insulin supplied in Canada. Higher-strength products, U-200 and U-300, are supplied in pens built for that concentration. Drawing a U-200 or U-300 product into a U-100 syringe multiplies the intended dose by two or three, turning a 10-unit dose into 20 or 30 units with no visible change on the scale. Keep the vial and the syringe in the same conversation: a U-100 syringe is for U-100 insulin, and any product supplied in a pen stays in its pen. If a clinic holds more than one concentration, store them apart and label the shelf, not only the carton.
How much insulin stays in the syringe after the plunger is fully depressed?
Some volume always remains in the hub and the needle, and no amount of plunger pressure moves it. That residual is a design property of the syringe, so it should be a stated number in millilitres rather than a figure a buyer estimates from a drawing. It matters most at the small end: a 2-unit dose from a syringe with a large hub residual delivers proportionally less insulin than a 20-unit dose from the same syringe. Ask for the measured residual volume and the method used to obtain it, and write it beside the product code in the protocol, because one clinic can hold two syringe brands with different hubs and one shared procedure.
What belongs in the batch record and the clinic protocol?
Single use with no recapping by hand; a sharps container within reach at every injection point; gloves changed between patients when staff give the injection; storage that keeps the carton dry and away from direct heat; and lot traceability from receipt through to the patient record. Waste is provincial: in Ontario, human blood waste is listed in Table A of guideline C-4 with a yellow label and the universal biohazard symbol, while other provinces publish their own rules for the same stream. Our 33G blood lancets, 32G pen needles and 1-quart sharps container carry the same documentation pattern, and volume requirements run through the wholesale enquiry desk.
| Attribute | As listed on this page | What to verify on the record |
|---|---|---|
| Barrel | 1 mL with fine graduations | Scale is U-100 (100 units per mL) and matches the vial in use |
| Needle gauge | 31G | 0.25 mm nominal outside diameter to ISO 9626:2016 |
| Needle length | 5/16 inch (7.94 mm) | Measured length and label agree with the requisition code |
| Needle attachment | Fixed needle, single use | Hub drawing, and no separate needle to attach |
| Product standard | Not stated on this page | Declaration citing ISO 8537:2016; not ISO 7886-1 alone |
| Sterilisation | Not stated on this page | ISO 11135:2014 for ethylene oxide, or the ISO 11137 series |
| Sterile barrier | Not stated on this page | ISO 11607-1:2019 qualification, with shelf life |
| Residual volume | Not stated on this page | Measured hub and needle dead space, in mL |
| Quality system | — | ISO 13485:2016 certificate held by the manufacturer |
| Distribution | CliniEco Medical, MDEL #35334 | Licence number recorded on the supplier file |
CliniEco Medical distributes injection consumables in Canada under MDEL #35334. This section is a specification reference for organisations building an insulin supply list; device and dose decisions stay with the treating team.
Related reading
- Diabetes management supplies: glucometers, strips and lancets
- Medical device classes in Canada explained
- Diabetes education clinic supplies
Listing note: this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our B2B enquiry form.