What does a Class B pre-vacuum cycle change for a clinic?

A gravity cycle pushes steam in and lets air out; a pre-vacuum cycle pulls air out first, which is what allows wrapped, hollow and porous loads to be sterilised reliably. That is why Class B benchtop units are the format dental clinics, veterinary practices, med-spas and tattoo studios look at: the loads those rooms actually run are wrapped and hollow, not open instruments on a tray.

What has to be true before a benchtop unit goes into service?

Three things, and none of them are optional: the unit has to be validated for the load types the clinic runs, the monitoring schedule has to be in place from the first cycle, and the records have to survive an inspection. In Ontario, the dental regulator's infection-control standard sets the expectation for sterilisation monitoring; the practical version is a biological indicator on every day the unit runs, plus chemical indicators in every pack and a record of both.

Where does this unit sit in that programme?

It does not publish chamber volume, cycle times or the licensing position, and a clinic should not plan an equipment replacement around a date that has not been confirmed. What can be done now is the part that takes longer than the purchase: the monitoring routine and the record keeping.

Format: Benchtop steam steriliser, pre-vacuum Class B cycle

Load types: Wrapped, hollow and porous loads

Intended settings: Dental clinics, veterinary practices, med-spas, tattoo studios

Monitoring expectation: Biological indicator each day the unit runs, chemical indicator in every pack

Distribution: CliniEco Medical — MDEL #35334

Format: Benchtop steam steriliser, pre-vacuum Class B cycle

Load types: Wrapped, hollow and porous loads

Intended settings: Dental clinics, veterinary practices, med-spas, tattoo studios

Monitoring expectation: Biological indicator each day the unit runs, chemical indicator in every pack

Distribution: CliniEco Medical — MDEL #35334

Benchtop steam steriliser — planned specification as listed
Property Planned / stated
Format Benchtop steam steriliser, pre-vacuum Class B cycle
Load types Wrapped, hollow and porous loads
Intended settings Dental clinics, veterinary practices, med-spas, tattoo studios
Chamber volume Not stated on the listing — confirmed before release
Cycle times Not stated on the listing — confirmed before release
Monitoring expectation Biological indicator each day the unit runs, chemical indicator in every pack
Distribution CliniEco Medical — MDEL #35334

What does the monitoring programme need on the shelf?

A 24-hour self-contained biological indicator, fifty per pack covers daily spore testing, and a Bowie-Dick test pack to ISO 11140-5 Type 2 is the daily vacuum check a pre-vacuum unit needs before the first load. For packaging, the Class 4 self-sealing pouch with dual indicators, two hundred per box is the consumable that keeps the routine running. Log sheets print from the compliance log centre and can be generated with the sterilization log generator on that page; clinic quantities are quoted at the clinic ordering desk, and the monitoring question itself can be booked with the compliance desk.

Imported and distributed in Canada by CliniEco Medical — MDEL #35334.

Product Overview

CliniEco Medical is preparing to introduce a benchtop Class B steam sterilizer (autoclave) for Canadian dental clinics, veterinary practices, med-spas, and tattoo studios. Class B pre-vacuum technology delivers validated sterilization for wrapped, hollow, and porous loads — the same standard trusted by modern clinics.

Why Wait for Our Autoclave?

  • Compliance-first — sourced from manufacturers holding Canadian Medical Device Licence (Class II) and FDA 510(k) clearance; distributed by CliniEco Medical
  • One-stop sterilization room — pairs with our sterilization pouches, rolls, Class 4/5 indicators, biological indicators (BI) and monitoring equipment
  • Local support — Toronto warehouse, Canadian-based distributor, full documentation
  • Open consumables ecosystem — works with standard sterilization pouches/tape/BI on the market (no lock-in)

Availability

We are currently completing model selection and sample validation. Expected retail range CAD $3,500–$4,500 depending on model (final pricing TBD at launch).

To be notified at launch or to discuss bulk/group pricing for multi-chair clinics, contact us at alina@clinieco.ca.

Part of the same sterilization system

Related articles

Request a B2B Quote

Prefer a quote? B2B & facility pricing — bulk discounts and standing orders on request. We reply within 1 business day.

Frequently Asked Questions

What consumables or accessories does it work with?
Open consumables ecosystem — works with standard sterilization pouches/tape/BI on the market (no lock-in) Availability Coming soon.
When will the steriliser be available?
The page is a pre-launch listing and does not publish a release date. Availability, chamber volume, cycle times and the licensing position are confirmed before release, so a replacement decision should not be planned around this page.
Why choose a pre-vacuum cycle?
Pulling air out before steam goes in is what makes wrapped, hollow and porous loads reliably sterilisable. Gravity units suit open instruments; the loads a dental or tattoo room runs are wrapped and hollow.
What monitoring does a Class B unit need?
A biological indicator on each day the unit runs, a Bowie-Dick test before the first load of the day on a pre-vacuum unit, and a chemical indicator in every pack, with all of it recorded. That schedule is the part to set up now.
Does the listing state chamber volume?
No. Chamber volume, cycle times and utility requirements are not published on this page and are confirmed before release. Those three decide whether a unit fits a room, so they matter before a purchase decision.
Can CliniEco supply the consumables in the meantime?
Yes. Biological indicators, Bowie-Dick packs, pouches and record sheets are listed and can be ordered now, which lets a clinic set up the monitoring routine before the hardware decision is made.